500 W IBC Solarmodul mit 108 Zellen. Voc 41.28 V · Isc 15.24 A · TcVoc -0.22%/°C.
Wählen Sie das Modul, das ersetzt werden soll
168 Module gefunden · 3532 Module ausgeschlossen
495 W
IBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 41.28 V | 41.15 V | 0.3% |
| Vmpp | 34.24 V | 34.14 V | 0.3% |
| Isc | 15.24 A | 15.17 A | 0.5% |
| Impp | 14.6 A | 14.5 A | 0.7% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
490 W
IBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 41.28 V | 41.02 V | 0.6% |
| Vmpp | 34.24 V | 34.04 V | 0.6% |
| Isc | 15.24 A | 15.1 A | 0.9% |
| Impp | 14.6 A | 14.4 A | 1.4% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 41.28 V | 41.02 V | 0.6% |
| Vmpp | 34.24 V | 34.04 V | 0.6% |
| Isc | 15.24 A | 15.1 A | 0.9% |
| Impp | 14.6 A | 14.4 A | 1.4% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
495 W
IBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 41.28 V | 41.25 V | 0.1% |
| Vmpp | 34.24 V | 34.07 V | 0.5% |
| Isc | 15.24 A | 15.19 A | 0.3% |
| Impp | 14.6 A | 14.53 A | 0.5% |
| TcVoc | -0.22 %/°C | -0.21 %/°C | ±0.010 %/°C |
| TcPmax | -0.26 %/°C | -0.24 %/°C | ±0.020 %/°C |
500 W
IBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 41.28 V | 41.35 V | 0.2% |
| Vmpp | 34.24 V | 34.17 V | 0.2% |
| Isc | 15.24 A | 15.3 A | 0.4% |
| Impp | 14.6 A | 14.63 A | 0.2% |
| TcVoc | -0.22 %/°C | -0.21 %/°C | ±0.010 %/°C |
| TcPmax | -0.26 %/°C | -0.24 %/°C | ±0.020 %/°C |
505 W
IBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 41.28 V | 41.45 V | 0.4% |
| Vmpp | 34.24 V | 34.27 V | 0.1% |
| Isc | 15.24 A | 15.41 A | 1.1% |
| Impp | 14.6 A | 14.74 A | 1.0% |
| TcVoc | -0.22 %/°C | -0.21 %/°C | ±0.010 %/°C |
| TcPmax | -0.26 %/°C | -0.24 %/°C | ±0.020 %/°C |
| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 41.28 V | 41.1 V | 0.4% |
| Vmpp | 34.24 V | 34.7 V | 1.3% |
| Isc | 15.24 A | 14.88 A | 2.4% |
| Impp | 14.6 A | 14.13 A | 3.2% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
495 W
IBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 41.28 V | 40.94 V | 0.8% |
| Vmpp | 34.24 V | 34.56 V | 0.9% |
| Isc | 15.24 A | 15.08 A | 1.0% |
| Impp | 14.6 A | 14.32 A | 1.9% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
485 W
IBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 41.28 V | 40.89 V | 0.9% |
| Vmpp | 34.24 V | 33.94 V | 0.9% |
| Isc | 15.24 A | 15.03 A | 1.4% |
| Impp | 14.6 A | 14.3 A | 2.1% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
485 W
IBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 41.28 V | 40.89 V | 0.9% |
| Vmpp | 34.24 V | 33.94 V | 0.9% |
| Isc | 15.24 A | 15.03 A | 1.4% |
| Impp | 14.6 A | 14.3 A | 2.1% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
495 W
IBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 41.28 V | 40.85 V | 1.0% |
| Vmpp | 34.24 V | 34.53 V | 0.8% |
| Isc | 15.24 A | 15.13 A | 0.7% |
| Impp | 14.6 A | 14.33 A | 1.8% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
490 W
IBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 41.28 V | 40.81 V | 1.1% |
| Vmpp | 34.24 V | 34.41 V | 0.5% |
| Isc | 15.24 A | 15.01 A | 1.5% |
| Impp | 14.6 A | 14.24 A | 2.5% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
String-Kompatibilitätsrechner
Prüfen, ob das Ersatzmodul zu Ihrem Wechselrichter passt
Modulsuche
Alle passenden Module für einen Wechselrichter finden
Sie haben bereits Module?
Finden Sie einen Wechselrichter, der zu Ihrer Modulanlage passt — MPPT-Bereich und DC/AC-Verhältnis automatisch geprüft.
So funktioniert der Algorithmus
Wie Module bewertet und zugeordnet werden
Voc
41.28 V
Vmpp
34.24 V
Isc
15.24 A
Impp
14.6 A
TcVoc
-0.22 %/°C
TcPmax
-0.26 %/°C
Pmax
500 W
Cells
108
Bifaciality
70%
Länge
1800 mm
Breite
1134 mm
Rahmentiefe
30 mm
Gewicht
24.8 kg
Das RECOM RCM-500-7RDBRCG M10R ist ein 500 W Solarmodul. Für einen kompatiblen Ersatz müssen die elektrischen Eigenschaften — insbesondere Voc, Vmpp, Isc und Temperaturkoeffizienten — übereinstimmen, um einen sicheren Betrieb im selben String zu gewährleisten.
Nutzen Sie das Formular oben, um passende Module zu finden. Überprüfen Sie dann den Ersatz im String-Kompatibilitätsrechner mit Ihrem Wechselrichter.
| Modell | Leistung | Voc | Isc |
|---|---|---|---|
| 470 W | 40.5 V | 14.82 A | |
| 475 W | 40.63 V | 14.89 A | |
| 480 W | 40.76 V | 14.96 A | |
| 485 W | 40.89 V | 15.03 A | |
| 490 W | 41.02 V | 15.1 A | |
| 495 W | 41.15 V | 15.17 A |
Die wichtigsten Spezifikationen: Zellenanzahl (genau 108), Voc nahe 41.28 V (±5%) und Temperaturkoeffizient TcVoc nahe -0.22%/°C. Weicht Voc stark ab, kann die String-Spannung bei Extremtemperaturen außerhalb des MPPT-Bereichs liegen. Der Modul-Finder oben prüft alle Kandidaten automatisch nach diesen Kriterien.
Ein leistungsstärkeres Modul hat meist einen höheren Vmpp oder Isc, was die String-Spannung und den Strom beeinflussen kann. Kleine Erhöhungen (bis 10–15%) sind in der Regel sicher, wenn die anderen Specs übereinstimmen. Der Finder zeigt einen Kompatibilitätsscore — 'Exakte Übereinstimmung' bedeutet sehr ähnliche Specs. Überprüfen Sie das Ersatzmodul immer im String-Kompatibilitätsrechner mit Ihrem Wechselrichter.
Wenn das Ersatzmodul eine deutlich andere Voc oder Vmpp hat, kann die String-Spannung außerhalb des MPPT-Bereichs des Wechselrichters liegen, was die Energieproduktion verringert oder Fehler verursacht. Dieser Effekt wird bei Temperaturextremen verstärkt. Der Finder berücksichtigt dies automatisch — er bewertet Kandidaten danach, wie eng die elektrischen Specs mit dem Original RECOM RCM-500-7RDBRCG M10R übereinstimmen.