505 W IBC Solarmodul mit 108 Zellen. Voc 40.85 V · Isc 15.62 A · TcVoc -0.2%/°C.
Wählen Sie das Modul, das ersetzt werden soll
78 Module gefunden · 3622 Module ausgeschlossen
505 W
HPBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 40.85 V | 40.85 V | 0.0% |
| Vmpp | 33.84 V | 33.84 V | 0.0% |
| Isc | 15.62 A | 15.62 A | 0.0% |
| Impp | 14.93 A | 14.93 A | 0.0% |
| TcVoc | -0.2 %/°C | -0.2 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
500 W
IBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 40.85 V | 40.75 V | 0.2% |
| Vmpp | 33.84 V | 33.73 V | 0.3% |
| Isc | 15.62 A | 15.53 A | 0.6% |
| Impp | 14.93 A | 14.83 A | 0.7% |
| TcVoc | -0.2 %/°C | -0.2 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
500 W
HPBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 40.85 V | 40.75 V | 0.2% |
| Vmpp | 33.84 V | 33.73 V | 0.3% |
| Isc | 15.62 A | 15.53 A | 0.6% |
| Impp | 14.93 A | 14.83 A | 0.7% |
| TcVoc | -0.2 %/°C | -0.2 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
495 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 40.85 V | 40.9 V | 0.1% |
| Vmpp | 33.84 V | 33.78 V | 0.2% |
| Isc | 15.62 A | 15.27 A | 2.2% |
| Impp | 14.93 A | 14.66 A | 1.8% |
| TcVoc | -0.2 %/°C | -0.2 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.27 %/°C | ±0.010 %/°C |
495 W
HPBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 40.85 V | 40.64 V | 0.5% |
| Vmpp | 33.84 V | 33.62 V | 0.7% |
| Isc | 15.62 A | 15.43 A | 1.2% |
| Impp | 14.93 A | 14.73 A | 1.3% |
| TcVoc | -0.2 %/°C | -0.2 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
495 W
IBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 40.85 V | 40.64 V | 0.5% |
| Vmpp | 33.84 V | 33.62 V | 0.7% |
| Isc | 15.62 A | 15.43 A | 1.2% |
| Impp | 14.93 A | 14.73 A | 1.3% |
| TcVoc | -0.2 %/°C | -0.2 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
495 W
IBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 40.85 V | 40.64 V | 0.5% |
| Vmpp | 33.84 V | 33.62 V | 0.7% |
| Isc | 15.62 A | 15.43 A | 1.2% |
| Impp | 14.93 A | 14.73 A | 1.3% |
| TcVoc | -0.2 %/°C | -0.2 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
495 W
HPBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 40.85 V | 40.64 V | 0.5% |
| Vmpp | 33.84 V | 33.62 V | 0.7% |
| Isc | 15.62 A | 15.43 A | 1.2% |
| Impp | 14.93 A | 14.73 A | 1.3% |
| TcVoc | -0.2 %/°C | -0.2 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
490 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 40.85 V | 40.77 V | 0.2% |
| Vmpp | 33.84 V | 33.68 V | 0.5% |
| Isc | 15.62 A | 15.17 A | 2.9% |
| Impp | 14.93 A | 14.56 A | 2.5% |
| TcVoc | -0.2 %/°C | -0.2 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.27 %/°C | ±0.010 %/°C |
485 W
HPBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 40.85 V | 40.64 V | 0.5% |
| Vmpp | 33.84 V | 33.62 V | 0.7% |
| Isc | 15.62 A | 15.08 A | 3.5% |
| Impp | 14.93 A | 14.43 A | 3.3% |
| TcVoc | -0.2 %/°C | -0.2 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
490 W
HPBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 40.85 V | 40.52 V | 0.8% |
| Vmpp | 33.84 V | 33.51 V | 1.0% |
| Isc | 15.62 A | 15.33 A | 1.9% |
| Impp | 14.93 A | 14.63 A | 2.0% |
| TcVoc | -0.2 %/°C | -0.2 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
490 W
IBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 40.85 V | 40.52 V | 0.8% |
| Vmpp | 33.84 V | 33.51 V | 1.0% |
| Isc | 15.62 A | 15.33 A | 1.9% |
| Impp | 14.93 A | 14.63 A | 2.0% |
| TcVoc | -0.2 %/°C | -0.2 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
String-Kompatibilitätsrechner
Prüfen, ob das Ersatzmodul zu Ihrem Wechselrichter passt
Modulsuche
Alle passenden Module für einen Wechselrichter finden
Sie haben bereits Module?
Finden Sie einen Wechselrichter, der zu Ihrer Modulanlage passt — MPPT-Bereich und DC/AC-Verhältnis automatisch geprüft.
So funktioniert der Algorithmus
Wie Module bewertet und zugeordnet werden
Voc
40.85 V
Vmpp
33.84 V
Isc
15.62 A
Impp
14.93 A
TcVoc
-0.2 %/°C
TcPmax
-0.26 %/°C
Pmax
505 W
Cells
108
Länge
1800 mm
Breite
1134 mm
Rahmentiefe
30 mm
Gewicht
21.6 kg
Das RECOM RCM-505-7RCG ist ein 505 W Solarmodul. Für einen kompatiblen Ersatz müssen die elektrischen Eigenschaften — insbesondere Voc, Vmpp, Isc und Temperaturkoeffizienten — übereinstimmen, um einen sicheren Betrieb im selben String zu gewährleisten.
Nutzen Sie das Formular oben, um passende Module zu finden. Überprüfen Sie dann den Ersatz im String-Kompatibilitätsrechner mit Ihrem Wechselrichter.
| Modell | Leistung | Voc | Isc |
|---|---|---|---|
| 495 W | 40.64 V | 15.43 A | |
| 500 W | 40.75 V | 15.53 A |
Die wichtigsten Spezifikationen: Zellenanzahl (genau 108), Voc nahe 40.85 V (±5%) und Temperaturkoeffizient TcVoc nahe -0.2%/°C. Weicht Voc stark ab, kann die String-Spannung bei Extremtemperaturen außerhalb des MPPT-Bereichs liegen. Der Modul-Finder oben prüft alle Kandidaten automatisch nach diesen Kriterien.
Ein leistungsstärkeres Modul hat meist einen höheren Vmpp oder Isc, was die String-Spannung und den Strom beeinflussen kann. Kleine Erhöhungen (bis 10–15%) sind in der Regel sicher, wenn die anderen Specs übereinstimmen. Der Finder zeigt einen Kompatibilitätsscore — 'Exakte Übereinstimmung' bedeutet sehr ähnliche Specs. Überprüfen Sie das Ersatzmodul immer im String-Kompatibilitätsrechner mit Ihrem Wechselrichter.
Wenn das Ersatzmodul eine deutlich andere Voc oder Vmpp hat, kann die String-Spannung außerhalb des MPPT-Bereichs des Wechselrichters liegen, was die Energieproduktion verringert oder Fehler verursacht. Dieser Effekt wird bei Temperaturextremen verstärkt. Der Finder berücksichtigt dies automatisch — er bewertet Kandidaten danach, wie eng die elektrischen Specs mit dem Original RECOM RCM-505-7RCG übereinstimmen.