550 W TOPCon Solarmodul mit 144 Zellen. Voc 50.21 V · Isc 14 A · TcVoc -0.25%/°C.
Wählen Sie das Modul, das ersetzt werden soll
88 Module gefunden · 3612 Module ausgeschlossen
550 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.21 V | 50.21 V | 0.0% |
| Vmpp | 41.5 V | 41.5 V | 0.0% |
| Isc | 14 A | 14 A | 0.0% |
| Impp | 13.26 A | 13.26 A | 0.0% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.3 %/°C | ±0.010 %/°C |
555 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.21 V | 50.34 V | 0.3% |
| Vmpp | 41.5 V | 41.64 V | 0.3% |
| Isc | 14 A | 14.07 A | 0.5% |
| Impp | 13.26 A | 13.33 A | 0.5% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
555 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.21 V | 50.14 V | 0.1% |
| Vmpp | 41.5 V | 41.29 V | 0.5% |
| Isc | 14 A | 14.19 A | 1.4% |
| Impp | 13.26 A | 13.44 A | 1.4% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
560 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.21 V | 50.32 V | 0.2% |
| Vmpp | 41.5 V | 41.49 V | 0.0% |
| Isc | 14 A | 14.25 A | 1.8% |
| Impp | 13.26 A | 13.5 A | 1.8% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
560 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.21 V | 50.32 V | 0.2% |
| Vmpp | 41.5 V | 41.49 V | 0.0% |
| Isc | 14 A | 14.25 A | 1.8% |
| Impp | 13.26 A | 13.5 A | 1.8% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
560 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.21 V | 50.47 V | 0.5% |
| Vmpp | 41.5 V | 41.77 V | 0.7% |
| Isc | 14 A | 14.15 A | 1.1% |
| Impp | 13.26 A | 13.41 A | 1.1% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
565 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.21 V | 50.5 V | 0.6% |
| Vmpp | 41.5 V | 41.68 V | 0.4% |
| Isc | 14 A | 14.31 A | 2.2% |
| Impp | 13.26 A | 13.56 A | 2.3% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
560 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.21 V | 50.47 V | 0.5% |
| Vmpp | 41.5 V | 41.77 V | 0.7% |
| Isc | 14 A | 14.15 A | 1.1% |
| Impp | 13.26 A | 13.41 A | 1.1% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.3 %/°C | ±0.010 %/°C |
555 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.21 V | 50.57 V | 0.7% |
| Vmpp | 41.5 V | 41.77 V | 0.7% |
| Isc | 14 A | 14.02 A | 0.1% |
| Impp | 13.26 A | 13.29 A | 0.2% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.3 %/°C | ±0.010 %/°C |
565 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.21 V | 50.5 V | 0.6% |
| Vmpp | 41.5 V | 41.68 V | 0.4% |
| Isc | 14 A | 14.31 A | 2.2% |
| Impp | 13.26 A | 13.56 A | 2.3% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
565 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.21 V | 50.6 V | 0.8% |
| Vmpp | 41.5 V | 41.92 V | 1.0% |
| Isc | 14 A | 14.23 A | 1.6% |
| Impp | 13.26 A | 13.48 A | 1.7% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
565 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.21 V | 50.6 V | 0.8% |
| Vmpp | 41.5 V | 41.92 V | 1.0% |
| Isc | 14 A | 14.23 A | 1.6% |
| Impp | 13.26 A | 13.48 A | 1.7% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.3 %/°C | ±0.010 %/°C |
String-Kompatibilitätsrechner
Prüfen, ob das Ersatzmodul zu Ihrem Wechselrichter passt
Modulsuche
Alle passenden Module für einen Wechselrichter finden
Sie haben bereits Module?
Finden Sie einen Wechselrichter, der zu Ihrer Modulanlage passt — MPPT-Bereich und DC/AC-Verhältnis automatisch geprüft.
So funktioniert der Algorithmus
Wie Module bewertet und zugeordnet werden
Voc
50.21 V
Vmpp
41.5 V
Isc
14 A
Impp
13.26 A
TcVoc
-0.25 %/°C
TcPmax
-0.29 %/°C
Pmax
550 W
Cells
144
Bifaciality
80%
Länge
2278 mm
Breite
1134 mm
Rahmentiefe
30 mm
Gewicht
32.2 kg
Das RECOM RCM-550-7DBNF ist ein 550 W Solarmodul. Für einen kompatiblen Ersatz müssen die elektrischen Eigenschaften — insbesondere Voc, Vmpp, Isc und Temperaturkoeffizienten — übereinstimmen, um einen sicheren Betrieb im selben String zu gewährleisten.
Nutzen Sie das Formular oben, um passende Module zu finden. Überprüfen Sie dann den Ersatz im String-Kompatibilitätsrechner mit Ihrem Wechselrichter.
| Modell | Leistung | Voc | Isc |
|---|---|---|---|
| 555 W | 50.34 V | 14.07 A | |
| 560 W | 50.47 V | 14.15 A | |
| 565 W | 50.6 V | 14.23 A | |
| 570 W | 50.74 V | 14.31 A | |
| 575 W | 50.88 V | 14.39 A | |
| 580 W | 51.02 V | 14.47 A | |
| 585 W | 51.16 V | 14.55 A | |
| 590 W | 51.31 V | 14.63 A |
Die wichtigsten Spezifikationen: Zellenanzahl (genau 144), Voc nahe 50.21 V (±5%) und Temperaturkoeffizient TcVoc nahe -0.25%/°C. Weicht Voc stark ab, kann die String-Spannung bei Extremtemperaturen außerhalb des MPPT-Bereichs liegen. Der Modul-Finder oben prüft alle Kandidaten automatisch nach diesen Kriterien.
Ein leistungsstärkeres Modul hat meist einen höheren Vmpp oder Isc, was die String-Spannung und den Strom beeinflussen kann. Kleine Erhöhungen (bis 10–15%) sind in der Regel sicher, wenn die anderen Specs übereinstimmen. Der Finder zeigt einen Kompatibilitätsscore — 'Exakte Übereinstimmung' bedeutet sehr ähnliche Specs. Überprüfen Sie das Ersatzmodul immer im String-Kompatibilitätsrechner mit Ihrem Wechselrichter.
Wenn das Ersatzmodul eine deutlich andere Voc oder Vmpp hat, kann die String-Spannung außerhalb des MPPT-Bereichs des Wechselrichters liegen, was die Energieproduktion verringert oder Fehler verursacht. Dieser Effekt wird bei Temperaturextremen verstärkt. Der Finder berücksichtigt dies automatisch — er bewertet Kandidaten danach, wie eng die elektrischen Specs mit dem Original RECOM RCM-550-7DBNF übereinstimmen.