670 W IBC Solarmodul mit 132 Zellen. Voc 49.94 V · Isc 17.03 A · TcVoc -0.2%/°C.
Wählen Sie das Modul, das ersetzt werden soll
47 Module gefunden · 3653 Module ausgeschlossen
665 W
IBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.94 V | 49.84 V | 0.2% |
| Vmpp | 41.23 V | 41.13 V | 0.2% |
| Isc | 17.03 A | 16.95 A | 0.5% |
| Impp | 16.25 A | 16.17 A | 0.5% |
| TcVoc | -0.2 %/°C | -0.2 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
665 W
HPBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.94 V | 50.02 V | 0.2% |
| Vmpp | 41.23 V | 41.28 V | 0.1% |
| Isc | 17.03 A | 16.78 A | 1.5% |
| Impp | 16.25 A | 16.11 A | 0.9% |
| TcVoc | -0.2 %/°C | -0.2 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
660 W
HPBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.94 V | 49.92 V | 0.0% |
| Vmpp | 41.23 V | 41.18 V | 0.1% |
| Isc | 17.03 A | 16.7 A | 1.9% |
| Impp | 16.25 A | 16.03 A | 1.4% |
| TcVoc | -0.2 %/°C | -0.2 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
660 W
HPBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.94 V | 49.92 V | 0.0% |
| Vmpp | 41.23 V | 41.18 V | 0.1% |
| Isc | 17.03 A | 16.7 A | 1.9% |
| Impp | 16.25 A | 16.03 A | 1.4% |
| TcVoc | -0.2 %/°C | -0.2 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
665 W
HPBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.94 V | 50.02 V | 0.2% |
| Vmpp | 41.23 V | 41.28 V | 0.1% |
| Isc | 17.03 A | 16.78 A | 1.5% |
| Impp | 16.25 A | 16.11 A | 0.9% |
| TcVoc | -0.2 %/°C | -0.2 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
665 W
HPBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.94 V | 50.02 V | 0.2% |
| Vmpp | 41.23 V | 41.28 V | 0.1% |
| Isc | 17.03 A | 16.78 A | 1.5% |
| Impp | 16.25 A | 16.11 A | 0.9% |
| TcVoc | -0.2 %/°C | -0.2 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
660 W
HPBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.94 V | 49.92 V | 0.0% |
| Vmpp | 41.23 V | 41.18 V | 0.1% |
| Isc | 17.03 A | 16.7 A | 1.9% |
| Impp | 16.25 A | 16.03 A | 1.4% |
| TcVoc | -0.2 %/°C | -0.2 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
670 W
HPBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.94 V | 50.12 V | 0.4% |
| Vmpp | 41.23 V | 41.38 V | 0.4% |
| Isc | 17.03 A | 16.86 A | 1.0% |
| Impp | 16.25 A | 16.19 A | 0.4% |
| TcVoc | -0.2 %/°C | -0.2 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
660 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.94 V | 49.95 V | 0.0% |
| Vmpp | 41.23 V | 41.26 V | 0.1% |
| Isc | 17.03 A | 16.67 A | 2.1% |
| Impp | 16.25 A | 16 A | 1.5% |
| TcVoc | -0.2 %/°C | -0.2 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.27 %/°C | ±0.010 %/°C |
670 W
HPBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.94 V | 50.12 V | 0.4% |
| Vmpp | 41.23 V | 41.38 V | 0.4% |
| Isc | 17.03 A | 16.86 A | 1.0% |
| Impp | 16.25 A | 16.19 A | 0.4% |
| TcVoc | -0.2 %/°C | -0.2 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
670 W
HPBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.94 V | 50.12 V | 0.4% |
| Vmpp | 41.23 V | 41.38 V | 0.4% |
| Isc | 17.03 A | 16.86 A | 1.0% |
| Impp | 16.25 A | 16.19 A | 0.4% |
| TcVoc | -0.2 %/°C | -0.2 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
660 W
IBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.94 V | 49.74 V | 0.4% |
| Vmpp | 41.23 V | 41.03 V | 0.5% |
| Isc | 17.03 A | 16.86 A | 1.0% |
| Impp | 16.25 A | 16.08 A | 1.0% |
| TcVoc | -0.2 %/°C | -0.2 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
String-Kompatibilitätsrechner
Prüfen, ob das Ersatzmodul zu Ihrem Wechselrichter passt
Modulsuche
Alle passenden Module für einen Wechselrichter finden
Sie haben bereits Module?
Finden Sie einen Wechselrichter, der zu Ihrer Modulanlage passt — MPPT-Bereich und DC/AC-Verhältnis automatisch geprüft.
So funktioniert der Algorithmus
Wie Module bewertet und zugeordnet werden
Voc
49.94 V
Vmpp
41.23 V
Isc
17.03 A
Impp
16.25 A
TcVoc
-0.2 %/°C
TcPmax
-0.26 %/°C
Pmax
670 W
Cells
132
Bifaciality
75%
Länge
2382 mm
Breite
1134 mm
Rahmentiefe
30 mm
Gewicht
33.5 kg
Das RECOM RCM-670-8DBRCM ist ein 670 W Solarmodul. Für einen kompatiblen Ersatz müssen die elektrischen Eigenschaften — insbesondere Voc, Vmpp, Isc und Temperaturkoeffizienten — übereinstimmen, um einen sicheren Betrieb im selben String zu gewährleisten.
Nutzen Sie das Formular oben, um passende Module zu finden. Überprüfen Sie dann den Ersatz im String-Kompatibilitätsrechner mit Ihrem Wechselrichter.
| Modell | Leistung | Voc | Isc |
|---|---|---|---|
| 635 W | 49.24 V | 16.45 A | |
| 640 W | 49.34 V | 16.54 A | |
| 645 W | 49.44 V | 16.62 A | |
| 650 W | 49.54 V | 16.7 A | |
| 655 W | 49.64 V | 16.78 A | |
| 660 W | 49.74 V | 16.86 A | |
| 665 W | 49.84 V | 16.95 A |
Die wichtigsten Spezifikationen: Zellenanzahl (genau 132), Voc nahe 49.94 V (±5%) und Temperaturkoeffizient TcVoc nahe -0.2%/°C. Weicht Voc stark ab, kann die String-Spannung bei Extremtemperaturen außerhalb des MPPT-Bereichs liegen. Der Modul-Finder oben prüft alle Kandidaten automatisch nach diesen Kriterien.
Ein leistungsstärkeres Modul hat meist einen höheren Vmpp oder Isc, was die String-Spannung und den Strom beeinflussen kann. Kleine Erhöhungen (bis 10–15%) sind in der Regel sicher, wenn die anderen Specs übereinstimmen. Der Finder zeigt einen Kompatibilitätsscore — 'Exakte Übereinstimmung' bedeutet sehr ähnliche Specs. Überprüfen Sie das Ersatzmodul immer im String-Kompatibilitätsrechner mit Ihrem Wechselrichter.
Wenn das Ersatzmodul eine deutlich andere Voc oder Vmpp hat, kann die String-Spannung außerhalb des MPPT-Bereichs des Wechselrichters liegen, was die Energieproduktion verringert oder Fehler verursacht. Dieser Effekt wird bei Temperaturextremen verstärkt. Der Finder berücksichtigt dies automatisch — er bewertet Kandidaten danach, wie eng die elektrischen Specs mit dem Original RECOM RCM-670-8DBRCM übereinstimmen.