450 W TOPCon Solarmodul mit 108 Zellen. Voc 39.8 V · Isc 14 A · TcVoc -0.25%/°C.
Wählen Sie das Modul, das ersetzt werden soll
142 Module gefunden · 3369 Module ausgeschlossen
450 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 39.8 V | 39.8 V | 0.0% |
| Vmpp | 33.2 V | 33.2 V | 0.0% |
| Isc | 14 A | 14 A | 0.0% |
| Impp | 13.5 A | 13.5 A | 0.0% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
450 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 39.8 V | 39.8 V | 0.0% |
| Vmpp | 33.2 V | 33.2 V | 0.0% |
| Isc | 14 A | 14 A | 0.0% |
| Impp | 13.5 A | 13.5 A | 0.0% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
450 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 39.8 V | 39.78 V | 0.1% |
| Vmpp | 33.2 V | 33.21 V | 0.0% |
| Isc | 14 A | 14 A | 0.0% |
| Impp | 13.5 A | 13.55 A | 0.4% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
445 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 39.8 V | 39.6 V | 0.5% |
| Vmpp | 33.2 V | 33 V | 0.6% |
| Isc | 14 A | 14 A | 0.0% |
| Impp | 13.5 A | 13.5 A | 0.0% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
445 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 39.8 V | 39.6 V | 0.5% |
| Vmpp | 33.2 V | 33 V | 0.6% |
| Isc | 14 A | 14 A | 0.0% |
| Impp | 13.5 A | 13.5 A | 0.0% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
445 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 39.8 V | 39.6 V | 0.5% |
| Vmpp | 33.2 V | 33 V | 0.6% |
| Isc | 14 A | 14 A | 0.0% |
| Impp | 13.5 A | 13.5 A | 0.0% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
445 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 39.8 V | 39.59 V | 0.5% |
| Vmpp | 33.2 V | 33.02 V | 0.5% |
| Isc | 14 A | 13.93 A | 0.5% |
| Impp | 13.5 A | 13.48 A | 0.1% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
455 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 39.8 V | 39.98 V | 0.5% |
| Vmpp | 33.2 V | 33.41 V | 0.6% |
| Isc | 14 A | 14.07 A | 0.5% |
| Impp | 13.5 A | 13.62 A | 0.9% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
455 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 39.8 V | 40 V | 0.5% |
| Vmpp | 33.2 V | 33.4 V | 0.6% |
| Isc | 14 A | 14.1 A | 0.7% |
| Impp | 13.5 A | 13.6 A | 0.7% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
455 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 39.8 V | 40 V | 0.5% |
| Vmpp | 33.2 V | 33.4 V | 0.6% |
| Isc | 14 A | 14.1 A | 0.7% |
| Impp | 13.5 A | 13.6 A | 0.7% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
455 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 39.8 V | 40 V | 0.5% |
| Vmpp | 33.2 V | 33.4 V | 0.6% |
| Isc | 14 A | 14.1 A | 0.7% |
| Impp | 13.5 A | 13.6 A | 0.7% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
440 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 39.8 V | 39.88 V | 0.2% |
| Vmpp | 33.2 V | 33.33 V | 0.4% |
| Isc | 14 A | 13.9 A | 0.7% |
| Impp | 13.5 A | 13.2 A | 2.2% |
| TcVoc | -0.25 %/°C | -0.24 %/°C | ±0.010 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
String-Kompatibilitätsrechner
Prüfen, ob das Ersatzmodul zu Ihrem Wechselrichter passt
Modulsuche
Alle passenden Module für einen Wechselrichter finden
Sie haben bereits Module?
Finden Sie einen Wechselrichter, der zu Ihrer Modulanlage passt — MPPT-Bereich und DC/AC-Verhältnis automatisch geprüft.
So funktioniert der Algorithmus
Wie Module bewertet und zugeordnet werden
Voc
39.8 V
Vmpp
33.2 V
Isc
14 A
Impp
13.5 A
TcVoc
-0.25 %/°C
TcPmax
-0.29 %/°C
Pmax
450 W
Cells
108
Länge
1762 mm
Breite
1134 mm
Rahmentiefe
35 mm
Gewicht
24.8 kg
Das Solarwatt Panel vision M 5.0 style 450 Wp ist ein 450 W Solarmodul. Für einen kompatiblen Ersatz müssen die elektrischen Eigenschaften — insbesondere Voc, Vmpp, Isc und Temperaturkoeffizienten — übereinstimmen, um einen sicheren Betrieb im selben String zu gewährleisten.
Nutzen Sie das Formular oben, um passende Module zu finden. Überprüfen Sie dann den Ersatz im String-Kompatibilitätsrechner mit Ihrem Wechselrichter.
| Modell | Leistung | Voc | Isc |
|---|---|---|---|
| 445 W | 39.6 V | 14 A | |
| 455 W | 40 V | 14.1 A |
Die wichtigsten Spezifikationen: Zellenanzahl (genau 108), Voc nahe 39.8 V (±5%) und Temperaturkoeffizient TcVoc nahe -0.25%/°C. Weicht Voc stark ab, kann die String-Spannung bei Extremtemperaturen außerhalb des MPPT-Bereichs liegen. Der Modul-Finder oben prüft alle Kandidaten automatisch nach diesen Kriterien.
Ein leistungsstärkeres Modul hat meist einen höheren Vmpp oder Isc, was die String-Spannung und den Strom beeinflussen kann. Kleine Erhöhungen (bis 10–15%) sind in der Regel sicher, wenn die anderen Specs übereinstimmen. Der Finder zeigt einen Kompatibilitätsscore — 'Exakte Übereinstimmung' bedeutet sehr ähnliche Specs. Überprüfen Sie das Ersatzmodul immer im String-Kompatibilitätsrechner mit Ihrem Wechselrichter.
Wenn das Ersatzmodul eine deutlich andere Voc oder Vmpp hat, kann die String-Spannung außerhalb des MPPT-Bereichs des Wechselrichters liegen, was die Energieproduktion verringert oder Fehler verursacht. Dieser Effekt wird bei Temperaturextremen verstärkt. Der Finder berücksichtigt dies automatisch — er bewertet Kandidaten danach, wie eng die elektrischen Specs mit dem Original Solarwatt Panel vision M 5.0 style 450 Wp übereinstimmen.