465 W TOPCon Solarmodul mit 96 Zellen. Voc 36.5 V · Isc 15.9 A · TcVoc -0.25%/°C.
Wählen Sie das Modul, das ersetzt werden soll
68 Module gefunden · 3443 Module ausgeschlossen
465 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 36.5 V | 36.5 V | 0.0% |
| Vmpp | 31.2 V | 31.2 V | 0.0% |
| Isc | 15.9 A | 15.9 A | 0.0% |
| Impp | 14.9 A | 14.9 A | 0.0% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
465 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 36.5 V | 36.5 V | 0.0% |
| Vmpp | 31.2 V | 31.2 V | 0.0% |
| Isc | 15.9 A | 15.9 A | 0.0% |
| Impp | 14.9 A | 14.9 A | 0.0% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
465 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 36.5 V | 36.46 V | 0.1% |
| Vmpp | 31.2 V | 31.21 V | 0.0% |
| Isc | 15.9 A | 15.88 A | 0.1% |
| Impp | 14.9 A | 14.91 A | 0.1% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
470 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 36.5 V | 36.59 V | 0.2% |
| Vmpp | 31.2 V | 30.97 V | 0.7% |
| Isc | 15.9 A | 15.93 A | 0.2% |
| Impp | 14.9 A | 15.18 A | 1.9% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
470 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 36.5 V | 36.6 V | 0.3% |
| Vmpp | 31.2 V | 31.5 V | 1.0% |
| Isc | 15.9 A | 15.9 A | 0.0% |
| Impp | 14.9 A | 15 A | 0.7% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
470 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 36.5 V | 36.6 V | 0.3% |
| Vmpp | 31.2 V | 31.5 V | 1.0% |
| Isc | 15.9 A | 15.9 A | 0.0% |
| Impp | 14.9 A | 15 A | 0.7% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
470 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 36.5 V | 36.6 V | 0.3% |
| Vmpp | 31.2 V | 31.5 V | 1.0% |
| Isc | 15.9 A | 15.9 A | 0.0% |
| Impp | 14.9 A | 15 A | 0.7% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
470 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 36.5 V | 36.56 V | 0.2% |
| Vmpp | 31.2 V | 30.97 V | 0.7% |
| Isc | 15.9 A | 16.03 A | 0.8% |
| Impp | 14.9 A | 15.18 A | 1.9% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
465 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 36.5 V | 36.57 V | 0.2% |
| Vmpp | 31.2 V | 30.94 V | 0.8% |
| Isc | 15.9 A | 15.81 A | 0.6% |
| Impp | 14.9 A | 15.03 A | 0.9% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
470 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 36.5 V | 36.6 V | 0.3% |
| Vmpp | 31.2 V | 31.47 V | 0.9% |
| Isc | 15.9 A | 15.93 A | 0.2% |
| Impp | 14.9 A | 14.95 A | 0.3% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
460 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 36.5 V | 36.49 V | 0.0% |
| Vmpp | 31.2 V | 30.96 V | 0.8% |
| Isc | 15.9 A | 15.82 A | 0.5% |
| Impp | 14.9 A | 14.86 A | 0.3% |
| TcVoc | -0.25 %/°C | -0.24 %/°C | ±0.010 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
470 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 36.5 V | 36.74 V | 0.7% |
| Vmpp | 31.2 V | 31.17 V | 0.1% |
| Isc | 15.9 A | 15.86 A | 0.3% |
| Impp | 14.9 A | 15.08 A | 1.2% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
String-Kompatibilitätsrechner
Prüfen, ob das Ersatzmodul zu Ihrem Wechselrichter passt
Modulsuche
Alle passenden Module für einen Wechselrichter finden
Sie haben bereits Module?
Finden Sie einen Wechselrichter, der zu Ihrer Modulanlage passt — MPPT-Bereich und DC/AC-Verhältnis automatisch geprüft.
So funktioniert der Algorithmus
Wie Module bewertet und zugeordnet werden
Voc
36.5 V
Vmpp
31.2 V
Isc
15.9 A
Impp
14.9 A
TcVoc
-0.25 %/°C
TcPmax
-0.29 %/°C
Pmax
465 W
Cells
96
Länge
1762 mm
Breite
1134 mm
Rahmentiefe
35 mm
Gewicht
24.8 kg
Das Solarwatt Panel vision M 5.5 black 465 Wp ist ein 465 W Solarmodul. Für einen kompatiblen Ersatz müssen die elektrischen Eigenschaften — insbesondere Voc, Vmpp, Isc und Temperaturkoeffizienten — übereinstimmen, um einen sicheren Betrieb im selben String zu gewährleisten.
Nutzen Sie das Formular oben, um passende Module zu finden. Überprüfen Sie dann den Ersatz im String-Kompatibilitätsrechner mit Ihrem Wechselrichter.
| Modell | Leistung | Voc | Isc |
|---|---|---|---|
| 460 W | 36.3 V | 15.8 A | |
| 470 W | 36.6 V | 15.9 A |
Die wichtigsten Spezifikationen: Zellenanzahl (genau 96), Voc nahe 36.5 V (±5%) und Temperaturkoeffizient TcVoc nahe -0.25%/°C. Weicht Voc stark ab, kann die String-Spannung bei Extremtemperaturen außerhalb des MPPT-Bereichs liegen. Der Modul-Finder oben prüft alle Kandidaten automatisch nach diesen Kriterien.
Ein leistungsstärkeres Modul hat meist einen höheren Vmpp oder Isc, was die String-Spannung und den Strom beeinflussen kann. Kleine Erhöhungen (bis 10–15%) sind in der Regel sicher, wenn die anderen Specs übereinstimmen. Der Finder zeigt einen Kompatibilitätsscore — 'Exakte Übereinstimmung' bedeutet sehr ähnliche Specs. Überprüfen Sie das Ersatzmodul immer im String-Kompatibilitätsrechner mit Ihrem Wechselrichter.
Wenn das Ersatzmodul eine deutlich andere Voc oder Vmpp hat, kann die String-Spannung außerhalb des MPPT-Bereichs des Wechselrichters liegen, was die Energieproduktion verringert oder Fehler verursacht. Dieser Effekt wird bei Temperaturextremen verstärkt. Der Finder berücksichtigt dies automatisch — er bewertet Kandidaten danach, wie eng die elektrischen Specs mit dem Original Solarwatt Panel vision M 5.5 black 465 Wp übereinstimmen.