725 W TOPCon Solarmodul mit 132 Zellen. Voc 48.6 V · Isc 18.79 A · TcVoc -0.25%/°C.
Wählen Sie das Modul, das ersetzt werden soll
107 Module gefunden · 3593 Module ausgeschlossen
725 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.6 V | 48.6 V | 0.0% |
| Vmpp | 41 V | 41 V | 0.0% |
| Isc | 18.79 A | 18.79 A | 0.0% |
| Impp | 17.68 A | 17.68 A | 0.0% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
725 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.6 V | 48.6 V | 0.0% |
| Vmpp | 41 V | 41 V | 0.0% |
| Isc | 18.79 A | 18.79 A | 0.0% |
| Impp | 17.68 A | 17.68 A | 0.0% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
725 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.6 V | 48.65 V | 0.1% |
| Vmpp | 41 V | 40.65 V | 0.9% |
| Isc | 18.79 A | 18.87 A | 0.4% |
| Impp | 17.68 A | 17.84 A | 0.9% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
720 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.6 V | 48.4 V | 0.4% |
| Vmpp | 41 V | 40.8 V | 0.5% |
| Isc | 18.79 A | 18.73 A | 0.3% |
| Impp | 17.68 A | 17.65 A | 0.2% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
730 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.6 V | 48.8 V | 0.4% |
| Vmpp | 41 V | 41.2 V | 0.5% |
| Isc | 18.79 A | 18.85 A | 0.3% |
| Impp | 17.68 A | 17.72 A | 0.2% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
720 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.6 V | 48.4 V | 0.4% |
| Vmpp | 41 V | 40.8 V | 0.5% |
| Isc | 18.79 A | 18.73 A | 0.3% |
| Impp | 17.68 A | 17.65 A | 0.2% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
730 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.6 V | 48.8 V | 0.4% |
| Vmpp | 41 V | 41.2 V | 0.5% |
| Isc | 18.79 A | 18.85 A | 0.3% |
| Impp | 17.68 A | 17.72 A | 0.2% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
720 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.6 V | 48.4 V | 0.4% |
| Vmpp | 41 V | 40.8 V | 0.5% |
| Isc | 18.79 A | 18.73 A | 0.3% |
| Impp | 17.68 A | 17.65 A | 0.2% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
730 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.6 V | 48.8 V | 0.4% |
| Vmpp | 41 V | 41.2 V | 0.5% |
| Isc | 18.79 A | 18.85 A | 0.3% |
| Impp | 17.68 A | 17.72 A | 0.2% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
715 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.6 V | 48.5 V | 0.2% |
| Vmpp | 41 V | 40.6 V | 1.0% |
| Isc | 18.79 A | 18.64 A | 0.8% |
| Impp | 17.68 A | 17.63 A | 0.3% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
730 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.6 V | 48.85 V | 0.5% |
| Vmpp | 41 V | 40.85 V | 0.4% |
| Isc | 18.79 A | 18.91 A | 0.6% |
| Impp | 17.68 A | 17.87 A | 1.1% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
720 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.6 V | 48.58 V | 0.0% |
| Vmpp | 41 V | 40.84 V | 0.4% |
| Isc | 18.79 A | 18.55 A | 1.3% |
| Impp | 17.68 A | 17.63 A | 0.3% |
| TcVoc | -0.25 %/°C | -0.26 %/°C | ±0.010 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
String-Kompatibilitätsrechner
Prüfen, ob das Ersatzmodul zu Ihrem Wechselrichter passt
Modulsuche
Alle passenden Module für einen Wechselrichter finden
Sie haben bereits Module?
Finden Sie einen Wechselrichter, der zu Ihrer Modulanlage passt — MPPT-Bereich und DC/AC-Verhältnis automatisch geprüft.
So funktioniert der Algorithmus
Wie Module bewertet und zugeordnet werden
Voc
48.6 V
Vmpp
41 V
Isc
18.79 A
Impp
17.68 A
TcVoc
-0.25 %/°C
TcPmax
-0.29 %/°C
Pmax
725 W
Cells
132
Bifaciality
80%
Länge
2384 mm
Breite
1303 mm
Rahmentiefe
33 mm
Gewicht
36.7 kg
Das DAH Solar DHN-66Y18/DG-725W ist ein 725 W Solarmodul. Für einen kompatiblen Ersatz müssen die elektrischen Eigenschaften — insbesondere Voc, Vmpp, Isc und Temperaturkoeffizienten — übereinstimmen, um einen sicheren Betrieb im selben String zu gewährleisten.
Nutzen Sie das Formular oben, um passende Module zu finden. Überprüfen Sie dann den Ersatz im String-Kompatibilitätsrechner mit Ihrem Wechselrichter.
| Modell | Leistung | Voc | Isc |
|---|---|---|---|
| 700 W | 47.6 V | 18.49 A | |
| 705 W | 47.8 V | 18.55 A | |
| 710 W | 48 V | 18.61 A | |
| 715 W | 48.2 V | 18.67 A | |
| 720 W | 48.4 V | 18.73 A | |
| 730 W | 48.8 V | 18.85 A |
Die wichtigsten Spezifikationen: Zellenanzahl (genau 132), Voc nahe 48.6 V (±5%) und Temperaturkoeffizient TcVoc nahe -0.25%/°C. Weicht Voc stark ab, kann die String-Spannung bei Extremtemperaturen außerhalb des MPPT-Bereichs liegen. Der Modul-Finder oben prüft alle Kandidaten automatisch nach diesen Kriterien.
Ein leistungsstärkeres Modul hat meist einen höheren Vmpp oder Isc, was die String-Spannung und den Strom beeinflussen kann. Kleine Erhöhungen (bis 10–15%) sind in der Regel sicher, wenn die anderen Specs übereinstimmen. Der Finder zeigt einen Kompatibilitätsscore — 'Exakte Übereinstimmung' bedeutet sehr ähnliche Specs. Überprüfen Sie das Ersatzmodul immer im String-Kompatibilitätsrechner mit Ihrem Wechselrichter.
Wenn das Ersatzmodul eine deutlich andere Voc oder Vmpp hat, kann die String-Spannung außerhalb des MPPT-Bereichs des Wechselrichters liegen, was die Energieproduktion verringert oder Fehler verursacht. Dieser Effekt wird bei Temperaturextremen verstärkt. Der Finder berücksichtigt dies automatisch — er bewertet Kandidaten danach, wie eng die elektrischen Specs mit dem Original DAH Solar DHN-66Y18/DG-725W übereinstimmen.