730 W TOPCon Solarmodul mit 132 Zellen. Voc 48.8 V · Isc 18.85 A · TcVoc -0.25%/°C.
Wählen Sie das Modul, das ersetzt werden soll
104 Module gefunden · 3596 Module ausgeschlossen
730 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.8 V | 48.8 V | 0.0% |
| Vmpp | 41.2 V | 41.2 V | 0.0% |
| Isc | 18.85 A | 18.85 A | 0.0% |
| Impp | 17.72 A | 17.72 A | 0.0% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
730 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.8 V | 48.8 V | 0.0% |
| Vmpp | 41.2 V | 41.2 V | 0.0% |
| Isc | 18.85 A | 18.85 A | 0.0% |
| Impp | 17.72 A | 17.72 A | 0.0% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
730 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.8 V | 48.85 V | 0.1% |
| Vmpp | 41.2 V | 40.85 V | 0.8% |
| Isc | 18.85 A | 18.91 A | 0.3% |
| Impp | 17.72 A | 17.87 A | 0.8% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
725 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.8 V | 48.6 V | 0.4% |
| Vmpp | 41.2 V | 41 V | 0.5% |
| Isc | 18.85 A | 18.79 A | 0.3% |
| Impp | 17.72 A | 17.68 A | 0.2% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
725 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.8 V | 48.6 V | 0.4% |
| Vmpp | 41.2 V | 41 V | 0.5% |
| Isc | 18.85 A | 18.79 A | 0.3% |
| Impp | 17.72 A | 17.68 A | 0.2% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
725 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.8 V | 48.6 V | 0.4% |
| Vmpp | 41.2 V | 41 V | 0.5% |
| Isc | 18.85 A | 18.79 A | 0.3% |
| Impp | 17.72 A | 17.68 A | 0.2% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
710 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.8 V | 48.82 V | 0.0% |
| Vmpp | 41.2 V | 40.93 V | 0.7% |
| Isc | 18.85 A | 18.4 A | 2.4% |
| Impp | 17.72 A | 17.35 A | 2.1% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
710 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.8 V | 48.82 V | 0.0% |
| Vmpp | 41.2 V | 40.76 V | 1.1% |
| Isc | 18.85 A | 18.52 A | 1.8% |
| Impp | 17.72 A | 17.45 A | 1.5% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
725 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.8 V | 48.65 V | 0.3% |
| Vmpp | 41.2 V | 40.65 V | 1.3% |
| Isc | 18.85 A | 18.87 A | 0.1% |
| Impp | 17.72 A | 17.84 A | 0.7% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
715 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.8 V | 48.88 V | 0.2% |
| Vmpp | 41.2 V | 40.77 V | 1.0% |
| Isc | 18.85 A | 18.6 A | 1.3% |
| Impp | 17.72 A | 17.54 A | 1.0% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
710 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.8 V | 48.9 V | 0.2% |
| Vmpp | 41.2 V | 40.93 V | 0.7% |
| Isc | 18.85 A | 18.4 A | 2.4% |
| Impp | 17.72 A | 17.35 A | 2.1% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
715 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.8 V | 49.02 V | 0.5% |
| Vmpp | 41.2 V | 40.93 V | 0.7% |
| Isc | 18.85 A | 18.56 A | 1.5% |
| Impp | 17.72 A | 17.5 A | 1.2% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
String-Kompatibilitätsrechner
Prüfen, ob das Ersatzmodul zu Ihrem Wechselrichter passt
Modulsuche
Alle passenden Module für einen Wechselrichter finden
Sie haben bereits Module?
Finden Sie einen Wechselrichter, der zu Ihrer Modulanlage passt — MPPT-Bereich und DC/AC-Verhältnis automatisch geprüft.
So funktioniert der Algorithmus
Wie Module bewertet und zugeordnet werden
Voc
48.8 V
Vmpp
41.2 V
Isc
18.85 A
Impp
17.72 A
TcVoc
-0.25 %/°C
TcPmax
-0.29 %/°C
Pmax
730 W
Cells
132
Bifaciality
80%
Länge
2384 mm
Breite
1303 mm
Rahmentiefe
33 mm
Gewicht
36.7 kg
Das DAH Solar DHN-66Y18/DG-730W ist ein 730 W Solarmodul. Für einen kompatiblen Ersatz müssen die elektrischen Eigenschaften — insbesondere Voc, Vmpp, Isc und Temperaturkoeffizienten — übereinstimmen, um einen sicheren Betrieb im selben String zu gewährleisten.
Nutzen Sie das Formular oben, um passende Module zu finden. Überprüfen Sie dann den Ersatz im String-Kompatibilitätsrechner mit Ihrem Wechselrichter.
| Modell | Leistung | Voc | Isc |
|---|---|---|---|
| 700 W | 47.6 V | 18.49 A | |
| 705 W | 47.8 V | 18.55 A | |
| 710 W | 48 V | 18.61 A | |
| 715 W | 48.2 V | 18.67 A | |
| 720 W | 48.4 V | 18.73 A | |
| 725 W | 48.6 V | 18.79 A |
Die wichtigsten Spezifikationen: Zellenanzahl (genau 132), Voc nahe 48.8 V (±5%) und Temperaturkoeffizient TcVoc nahe -0.25%/°C. Weicht Voc stark ab, kann die String-Spannung bei Extremtemperaturen außerhalb des MPPT-Bereichs liegen. Der Modul-Finder oben prüft alle Kandidaten automatisch nach diesen Kriterien.
Ein leistungsstärkeres Modul hat meist einen höheren Vmpp oder Isc, was die String-Spannung und den Strom beeinflussen kann. Kleine Erhöhungen (bis 10–15%) sind in der Regel sicher, wenn die anderen Specs übereinstimmen. Der Finder zeigt einen Kompatibilitätsscore — 'Exakte Übereinstimmung' bedeutet sehr ähnliche Specs. Überprüfen Sie das Ersatzmodul immer im String-Kompatibilitätsrechner mit Ihrem Wechselrichter.
Wenn das Ersatzmodul eine deutlich andere Voc oder Vmpp hat, kann die String-Spannung außerhalb des MPPT-Bereichs des Wechselrichters liegen, was die Energieproduktion verringert oder Fehler verursacht. Dieser Effekt wird bei Temperaturextremen verstärkt. Der Finder berücksichtigt dies automatisch — er bewertet Kandidaten danach, wie eng die elektrischen Specs mit dem Original DAH Solar DHN-66Y18/DG-730W übereinstimmen.