690 W ABC solar panel with 144 cells. Voc 55.2 V · Isc 15.59 A · TcVoc -0.22%/°C.
Select the panel you want to replace
8 panels found · 3702 panels excluded
685 W
ABC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 55.2 V | 55 V | 0.4% |
| Vmpp | 46.1 V | 46 V | 0.2% |
| Isc | 15.59 A | 15.53 A | 0.4% |
| Impp | 14.97 A | 14.9 A | 0.5% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
680 W
ABC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 55.2 V | 54.8 V | 0.7% |
| Vmpp | 46.1 V | 45.9 V | 0.4% |
| Isc | 15.59 A | 15.47 A | 0.8% |
| Impp | 14.97 A | 14.82 A | 1.0% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
675 W
ABC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 55.2 V | 54.65 V | 1.0% |
| Vmpp | 46.1 V | 45.8 V | 0.7% |
| Isc | 15.59 A | 15.41 A | 1.2% |
| Impp | 14.97 A | 14.74 A | 1.5% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
670 W
ABC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 55.2 V | 54.8 V | 0.7% |
| Vmpp | 46.1 V | 45.5 V | 1.3% |
| Isc | 15.59 A | 15.36 A | 1.5% |
| Impp | 14.97 A | 14.73 A | 1.6% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
670 W
ABC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 55.2 V | 54.5 V | 1.3% |
| Vmpp | 46.1 V | 45.7 V | 0.9% |
| Isc | 15.59 A | 15.35 A | 1.5% |
| Impp | 14.97 A | 14.67 A | 2.0% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
670 W
HPBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 55.2 V | 54.3 V | 1.6% |
| Vmpp | 46.1 V | 44.96 V | 2.5% |
| Isc | 15.59 A | 15.6 A | 0.1% |
| Impp | 14.97 A | 14.91 A | 0.4% |
| TcVoc | -0.22 %/°C | -0.2 %/°C | ±0.020 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
670 W
HPBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 55.2 V | 54.3 V | 1.6% |
| Vmpp | 46.1 V | 44.96 V | 2.5% |
| Isc | 15.59 A | 15.6 A | 0.1% |
| Impp | 14.97 A | 14.91 A | 0.4% |
| TcVoc | -0.22 %/°C | -0.2 %/°C | ±0.020 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
670 W
HPBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 55.2 V | 54.3 V | 1.6% |
| Vmpp | 46.1 V | 44.96 V | 2.5% |
| Isc | 15.59 A | 15.6 A | 0.1% |
| Impp | 14.97 A | 14.91 A | 0.4% |
| TcVoc | -0.22 %/°C | -0.2 %/°C | ±0.020 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
String Compatibility Calculator
Verify the replacement panel works with your inverter
Panel Matcher
Find all compatible panels for a specific inverter
Already have panels?
Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.
How the Algorithm Works
Learn how panels are scored and matched
Voc
55.2 V
Vmpp
46.1 V
Isc
15.59 A
Impp
14.97 A
TcVoc
-0.22 %/°C
TcPmax
-0.26 %/°C
Pmax
690 W
Cells
144
Length
2382 mm
Width
1134 mm
Thickness
30 mm
Weight
28.2 kg
The Aiko Solar AIKO-A690-MDE72Mw is a 690 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.
Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.
| Model | Power | Voc | Isc |
|---|---|---|---|
| AIKO-A655-MDE72Mw | 655 W | 54.1 V | 15.16 A |
| AIKO-A660-MDE72Mw | 660 W | 54.2 V | 15.22 A |
| AIKO-A665-MDE72Mw | 665 W | 54.35 V | 15.28 A |
| AIKO-A670-MDE72Mw | 670 W | 54.5 V | 15.35 A |
| AIKO-A675-MDE72Mw | 675 W | 54.65 V | 15.41 A |
| AIKO-A680-MDE72Mw | 680 W | 54.8 V | 15.47 A |
| AIKO-A685-MDE72Mw | 685 W | 55 V | 15.53 A |
The most critical specs to match are: cell count (must be exactly 144), Voc close to 55.2 V (within ±5%), and temperature coefficient TcVoc close to -0.22%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.
A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.
If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original Aiko Solar AIKO-A690-MDE72Mw.