585 W TOPCon solar panel with 144 cells. Voc 51.67 V · Isc 14.43 A · TcVoc -0.25%/°C.
Select the panel you want to replace
215 panels found · 3485 panels excluded
585 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.67 V | 51.67 V | 0.0% |
| Vmpp | 42.74 V | 42.74 V | 0.0% |
| Isc | 14.43 A | 14.43 A | 0.0% |
| Impp | 13.69 A | 13.69 A | 0.0% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
590 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.67 V | 51.68 V | 0.0% |
| Vmpp | 42.74 V | 42.91 V | 0.4% |
| Isc | 14.43 A | 14.48 A | 0.3% |
| Impp | 13.69 A | 13.75 A | 0.4% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
585 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.67 V | 51.55 V | 0.2% |
| Vmpp | 42.74 V | 42.79 V | 0.1% |
| Isc | 14.43 A | 14.4 A | 0.2% |
| Impp | 13.69 A | 13.67 A | 0.1% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
590 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.67 V | 51.67 V | 0.0% |
| Vmpp | 42.74 V | 42.94 V | 0.5% |
| Isc | 14.43 A | 14.55 A | 0.8% |
| Impp | 13.69 A | 13.76 A | 0.5% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
585 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.67 V | 51.48 V | 0.4% |
| Vmpp | 42.74 V | 42.78 V | 0.1% |
| Isc | 14.43 A | 14.5 A | 0.5% |
| Impp | 13.69 A | 13.7 A | 0.1% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
590 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.67 V | 51.86 V | 0.4% |
| Vmpp | 42.74 V | 42.88 V | 0.3% |
| Isc | 14.43 A | 14.49 A | 0.4% |
| Impp | 13.69 A | 13.76 A | 0.5% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
580 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.67 V | 51.47 V | 0.4% |
| Vmpp | 42.74 V | 42.59 V | 0.4% |
| Isc | 14.43 A | 14.37 A | 0.4% |
| Impp | 13.69 A | 13.62 A | 0.5% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
590 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.67 V | 51.87 V | 0.4% |
| Vmpp | 42.74 V | 42.89 V | 0.4% |
| Isc | 14.43 A | 14.49 A | 0.4% |
| Impp | 13.69 A | 13.76 A | 0.5% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
580 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.67 V | 51.47 V | 0.4% |
| Vmpp | 42.74 V | 42.59 V | 0.4% |
| Isc | 14.43 A | 14.37 A | 0.4% |
| Impp | 13.69 A | 13.62 A | 0.5% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
575 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.67 V | 51.79 V | 0.2% |
| Vmpp | 42.74 V | 42.78 V | 0.1% |
| Isc | 14.43 A | 14.19 A | 1.7% |
| Impp | 13.69 A | 13.45 A | 1.8% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
585 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.67 V | 51.57 V | 0.2% |
| Vmpp | 42.74 V | 42.84 V | 0.2% |
| Isc | 14.43 A | 14.18 A | 1.7% |
| Impp | 13.69 A | 13.66 A | 0.2% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.3 %/°C | ±0.010 %/°C |
580 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.67 V | 51.42 V | 0.5% |
| Vmpp | 42.74 V | 42.68 V | 0.1% |
| Isc | 14.43 A | 14.32 A | 0.8% |
| Impp | 13.69 A | 13.59 A | 0.7% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
String Compatibility Calculator
Verify the replacement panel works with your inverter
Panel Matcher
Find all compatible panels for a specific inverter
Already have panels?
Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.
How the Algorithm Works
Learn how panels are scored and matched
Voc
51.67 V
Vmpp
42.74 V
Isc
14.43 A
Impp
13.69 A
TcVoc
-0.25 %/°C
TcPmax
-0.29 %/°C
Pmax
585 W
Cells
144
Bifaciality
80%
Length
2278 mm
Width
1134 mm
Thickness
30 mm
Weight
32 kg
The JinkoSolar JKM585N-72HL4-BDV-F5C1 is a 585 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.
Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.
| Model | Power | Voc | Isc |
|---|---|---|---|
| 570 W | 51.07 V | 14.25 A | |
| 575 W | 51.27 V | 14.31 A | |
| 580 W | 51.47 V | 14.37 A | |
| 590 W | 51.86 V | 14.49 A |
The most critical specs to match are: cell count (must be exactly 144), Voc close to 51.67 V (within ±5%), and temperature coefficient TcVoc close to -0.25%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.
A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.
If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original JinkoSolar JKM585N-72HL4-BDV-F5C1.