545 W PERC solar panel with 144 cells. Voc 49.45 V · Isc 13.96 A · TcVoc -0.285%/°C.
Select the panel you want to replace
73 panels found · 3637 panels excluded
540 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.45 V | 49.28 V | 0.3% |
| Vmpp | 41.24 V | 41.1 V | 0.3% |
| Isc | 13.96 A | 13.89 A | 0.5% |
| Impp | 13.22 A | 13.15 A | 0.5% |
| TcVoc | -0.285 %/°C | -0.285 %/°C | ±0.000 %/°C |
| TcPmax | -0.36 %/°C | -0.36 %/°C | ±0.000 %/°C |
550 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.45 V | 49.63 V | 0.4% |
| Vmpp | 41.24 V | 41.39 V | 0.4% |
| Isc | 13.96 A | 14.03 A | 0.5% |
| Impp | 13.22 A | 13.29 A | 0.5% |
| TcVoc | -0.285 %/°C | -0.285 %/°C | ±0.000 %/°C |
| TcPmax | -0.36 %/°C | -0.36 %/°C | ±0.000 %/°C |
545 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.45 V | 49.52 V | 0.1% |
| Vmpp | 41.24 V | 40.8 V | 1.1% |
| Isc | 13.96 A | 13.94 A | 0.1% |
| Impp | 13.22 A | 13.36 A | 1.1% |
| TcVoc | -0.285 %/°C | -0.28 %/°C | ±0.005 %/°C |
| TcPmax | -0.36 %/°C | -0.35 %/°C | ±0.010 %/°C |
540 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.45 V | 49.42 V | 0.1% |
| Vmpp | 41.24 V | 40.7 V | 1.3% |
| Isc | 13.96 A | 13.85 A | 0.8% |
| Impp | 13.22 A | 13.27 A | 0.4% |
| TcVoc | -0.285 %/°C | -0.28 %/°C | ±0.005 %/°C |
| TcPmax | -0.36 %/°C | -0.35 %/°C | ±0.010 %/°C |
550 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.45 V | 49.62 V | 0.3% |
| Vmpp | 41.24 V | 40.9 V | 0.8% |
| Isc | 13.96 A | 14.03 A | 0.5% |
| Impp | 13.22 A | 13.45 A | 1.7% |
| TcVoc | -0.285 %/°C | -0.28 %/°C | ±0.005 %/°C |
| TcPmax | -0.36 %/°C | -0.35 %/°C | ±0.010 %/°C |
555 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.45 V | 49.81 V | 0.7% |
| Vmpp | 41.24 V | 41.54 V | 0.7% |
| Isc | 13.96 A | 14.12 A | 1.1% |
| Impp | 13.22 A | 13.37 A | 1.1% |
| TcVoc | -0.285 %/°C | -0.285 %/°C | ±0.000 %/°C |
| TcPmax | -0.36 %/°C | -0.36 %/°C | ±0.000 %/°C |
540 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.45 V | 49.4 V | 0.1% |
| Vmpp | 41.24 V | 41.2 V | 0.1% |
| Isc | 13.96 A | 13.87 A | 0.6% |
| Impp | 13.22 A | 13.11 A | 0.8% |
| TcVoc | -0.285 %/°C | -0.26 %/°C | ±0.025 %/°C |
| TcPmax | -0.36 %/°C | -0.36 %/°C | ±0.000 %/°C |
540 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.45 V | 49.6 V | 0.3% |
| Vmpp | 41.24 V | 41.64 V | 1.0% |
| Isc | 13.96 A | 13.86 A | 0.7% |
| Impp | 13.22 A | 12.97 A | 1.9% |
| TcVoc | -0.285 %/°C | -0.275 %/°C | ±0.010 %/°C |
| TcPmax | -0.36 %/°C | -0.35 %/°C | ±0.010 %/°C |
555 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.45 V | 49.72 V | 0.5% |
| Vmpp | 41.24 V | 40.99 V | 0.6% |
| Isc | 13.96 A | 14.12 A | 1.1% |
| Impp | 13.22 A | 13.54 A | 2.4% |
| TcVoc | -0.285 %/°C | -0.28 %/°C | ±0.005 %/°C |
| TcPmax | -0.36 %/°C | -0.35 %/°C | ±0.010 %/°C |
540 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.45 V | 49.7 V | 0.5% |
| Vmpp | 41.24 V | 41.77 V | 1.3% |
| Isc | 13.96 A | 13.73 A | 1.6% |
| Impp | 13.22 A | 12.93 A | 2.2% |
| TcVoc | -0.285 %/°C | -0.285 %/°C | ±0.000 %/°C |
| TcPmax | -0.36 %/°C | -0.35 %/°C | ±0.010 %/°C |
545 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.45 V | 49.6 V | 0.3% |
| Vmpp | 41.24 V | 41.4 V | 0.4% |
| Isc | 13.96 A | 13.93 A | 0.2% |
| Impp | 13.22 A | 13.17 A | 0.4% |
| TcVoc | -0.285 %/°C | -0.26 %/°C | ±0.025 %/°C |
| TcPmax | -0.36 %/°C | -0.36 %/°C | ±0.000 %/°C |
535 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.45 V | 49.46 V | 0.0% |
| Vmpp | 41.24 V | 41.6 V | 0.9% |
| Isc | 13.96 A | 13.76 A | 1.4% |
| Impp | 13.22 A | 12.88 A | 2.6% |
| TcVoc | -0.285 %/°C | -0.27 %/°C | ±0.015 %/°C |
| TcPmax | -0.36 %/°C | -0.35 %/°C | ±0.010 %/°C |
String Compatibility Calculator
Verify the replacement panel works with your inverter
Panel Matcher
Find all compatible panels for a specific inverter
Already have panels?
Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.
How the Algorithm Works
Learn how panels are scored and matched
Voc
49.45 V
Vmpp
41.24 V
Isc
13.96 A
Impp
13.22 A
TcVoc
-0.285 %/°C
TcPmax
-0.36 %/°C
Pmax
545 W
Cells
144
Length
2279 mm
Width
1134 mm
Thickness
35 mm
Weight
29 kg
The Luxor Solar LX-545M/182-144+ SW HC is a 545 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.
Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.
| Model | Power | Voc | Isc |
|---|---|---|---|
| LX-540M/182-144+ SW HC | 540 W | 49.28 V | 13.89 A |
| LX-550M/182-144+ SW HC | 550 W | 49.63 V | 14.03 A |
| LX-555M/182-144+ SW HC | 555 W | 49.81 V | 14.12 A |
| LX-560M/182-144+ SW HC | 560 W | 49.99 V | 14.19 A |
The most critical specs to match are: cell count (must be exactly 144), Voc close to 49.45 V (within ±5%), and temperature coefficient TcVoc close to -0.285%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.
A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.
If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original Luxor Solar LX-545M/182-144+ SW HC.