515 W TOPCon solar panel with 108 cells. Voc 40.22 V · Isc 16.12 A · TcVoc -0.25%/°C.
Select the panel you want to replace
68 panels found · 3642 panels excluded
510 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 40.22 V | 40.16 V | 0.1% |
| Vmpp | 33.57 V | 33.47 V | 0.3% |
| Isc | 16.12 A | 16.08 A | 0.2% |
| Impp | 15.34 A | 15.24 A | 0.7% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
520 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 40.22 V | 40.26 V | 0.1% |
| Vmpp | 33.57 V | 33.67 V | 0.3% |
| Isc | 16.12 A | 16.16 A | 0.2% |
| Impp | 15.34 A | 15.44 A | 0.7% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
515 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 40.22 V | 40.2 V | 0.0% |
| Vmpp | 33.57 V | 34 V | 1.3% |
| Isc | 16.12 A | 16.15 A | 0.2% |
| Impp | 15.34 A | 15.16 A | 1.2% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
515 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 40.22 V | 40.15 V | 0.2% |
| Vmpp | 33.57 V | 33.95 V | 1.1% |
| Isc | 16.12 A | 16.01 A | 0.7% |
| Impp | 15.34 A | 15.17 A | 1.1% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
510 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 40.22 V | 40 V | 0.5% |
| Vmpp | 33.57 V | 33.8 V | 0.7% |
| Isc | 16.12 A | 16.1 A | 0.1% |
| Impp | 15.34 A | 15.1 A | 1.6% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
505 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 40.22 V | 40.3 V | 0.2% |
| Vmpp | 33.57 V | 33.5 V | 0.2% |
| Isc | 16.12 A | 15.89 A | 1.4% |
| Impp | 15.34 A | 15.09 A | 1.6% |
| TcVoc | -0.25 %/°C | -0.24 %/°C | ±0.010 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
505 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 40.22 V | 40.3 V | 0.2% |
| Vmpp | 33.57 V | 33.5 V | 0.2% |
| Isc | 16.12 A | 15.89 A | 1.4% |
| Impp | 15.34 A | 15.09 A | 1.6% |
| TcVoc | -0.25 %/°C | -0.24 %/°C | ±0.010 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
505 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 40.22 V | 39.99 V | 0.6% |
| Vmpp | 33.57 V | 33.32 V | 0.7% |
| Isc | 16.12 A | 16.02 A | 0.6% |
| Impp | 15.34 A | 15.16 A | 1.2% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
505 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 40.22 V | 40.3 V | 0.2% |
| Vmpp | 33.57 V | 33.5 V | 0.2% |
| Isc | 16.12 A | 15.89 A | 1.4% |
| Impp | 15.34 A | 15.09 A | 1.6% |
| TcVoc | -0.25 %/°C | -0.24 %/°C | ±0.010 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
505 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 40.22 V | 40.3 V | 0.2% |
| Vmpp | 33.57 V | 33.5 V | 0.2% |
| Isc | 16.12 A | 15.89 A | 1.4% |
| Impp | 15.34 A | 15.09 A | 1.6% |
| TcVoc | -0.25 %/°C | -0.24 %/°C | ±0.010 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
520 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 40.22 V | 40.35 V | 0.3% |
| Vmpp | 33.57 V | 34.15 V | 1.7% |
| Isc | 16.12 A | 16.07 A | 0.3% |
| Impp | 15.34 A | 15.23 A | 0.7% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
510 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 40.22 V | 39.95 V | 0.7% |
| Vmpp | 33.57 V | 33.75 V | 0.5% |
| Isc | 16.12 A | 15.95 A | 1.1% |
| Impp | 15.34 A | 15.12 A | 1.4% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
String Compatibility Calculator
Verify the replacement panel works with your inverter
Panel Matcher
Find all compatible panels for a specific inverter
Already have panels?
Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.
How the Algorithm Works
Learn how panels are scored and matched
Voc
40.22 V
Vmpp
33.57 V
Isc
16.12 A
Impp
15.34 A
TcVoc
-0.25 %/°C
TcPmax
-0.29 %/°C
Pmax
515 W
Cells
108
Length
1961 mm
Width
1134 mm
Thickness
30 mm
Weight
24 kg
The Ulica Solar UL-515M-108DDGN is a 515 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.
Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.
| Model | Power | Voc | Isc |
|---|---|---|---|
| UL-495M-108DDGN | 495 W | 39.67 V | 15.9 A |
| UL-500M-108DDGN | 500 W | 39.83 V | 15.96 A |
| UL-505M-108DDGN | 505 W | 39.99 V | 16.02 A |
| UL-510M-108DDGN | 510 W | 40.16 V | 16.08 A |
| UL-520M-108DDGN | 520 W | 40.26 V | 16.16 A |
The most critical specs to match are: cell count (must be exactly 108), Voc close to 40.22 V (within ±5%), and temperature coefficient TcVoc close to -0.25%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.
A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.
If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original Ulica Solar UL-515M-108DDGN.