655 W ABC solar panel with 156 cells. Voc 58.74 V · Isc 14.21 A · TcVoc -0.22%/°C.
Select the panel you want to replace
33 panels found · 4306 panels excluded
660 W
ABC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 58.74 V | 58.8 V | 0.1% |
| Vmpp | 48.61 V | 48.67 V | 0.1% |
| Isc | 14.21 A | 14.28 A | 0.5% |
| Impp | 13.48 A | 13.57 A | 0.7% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
665 W
ABC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 58.74 V | 58.86 V | 0.2% |
| Vmpp | 48.61 V | 48.73 V | 0.2% |
| Isc | 14.21 A | 14.35 A | 1.0% |
| Impp | 13.48 A | 13.64 A | 1.2% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
670 W
ABC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 58.74 V | 58.92 V | 0.3% |
| Vmpp | 48.61 V | 48.79 V | 0.4% |
| Isc | 14.21 A | 14.42 A | 1.5% |
| Impp | 13.48 A | 13.74 A | 1.9% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
675 W
ABC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 58.74 V | 58.98 V | 0.4% |
| Vmpp | 48.61 V | 48.85 V | 0.5% |
| Isc | 14.21 A | 14.49 A | 2.0% |
| Impp | 13.48 A | 13.82 A | 2.5% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
660 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 58.74 V | 58.42 V | 0.5% |
| Vmpp | 48.61 V | 48.35 V | 0.5% |
| Isc | 14.21 A | 14.23 A | 0.1% |
| Impp | 13.48 A | 13.65 A | 1.3% |
| TcVoc | -0.22 %/°C | -0.24 %/°C | ±0.020 %/°C |
| TcPmax | -0.26 %/°C | -0.29 %/°C | ±0.030 %/°C |
655 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 58.74 V | 58.22 V | 0.9% |
| Vmpp | 48.61 V | 48.21 V | 0.8% |
| Isc | 14.21 A | 14.19 A | 0.1% |
| Impp | 13.48 A | 13.59 A | 0.8% |
| TcVoc | -0.22 %/°C | -0.24 %/°C | ±0.020 %/°C |
| TcPmax | -0.26 %/°C | -0.29 %/°C | ±0.030 %/°C |
650 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 58.74 V | 58.02 V | 1.2% |
| Vmpp | 48.61 V | 48.04 V | 1.2% |
| Isc | 14.21 A | 14.14 A | 0.5% |
| Impp | 13.48 A | 13.53 A | 0.4% |
| TcVoc | -0.22 %/°C | -0.24 %/°C | ±0.020 %/°C |
| TcPmax | -0.26 %/°C | -0.29 %/°C | ±0.030 %/°C |
650 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 58.74 V | 58.1 V | 1.1% |
| Vmpp | 48.61 V | 48.24 V | 0.8% |
| Isc | 14.21 A | 14.24 A | 0.2% |
| Impp | 13.48 A | 13.49 A | 0.1% |
| TcVoc | -0.22 %/°C | -0.25 %/°C | ±0.030 %/°C |
| TcPmax | -0.26 %/°C | -0.29 %/°C | ±0.030 %/°C |
645 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 58.74 V | 57.6 V | 1.9% |
| Vmpp | 48.61 V | 48.36 V | 0.5% |
| Isc | 14.21 A | 14.05 A | 1.1% |
| Impp | 13.48 A | 13.34 A | 1.0% |
| TcVoc | -0.22 %/°C | -0.24 %/°C | ±0.020 %/°C |
| TcPmax | -0.26 %/°C | -0.28 %/°C | ±0.020 %/°C |
645 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 58.74 V | 57.82 V | 1.6% |
| Vmpp | 48.61 V | 47.89 V | 1.5% |
| Isc | 14.21 A | 14.1 A | 0.8% |
| Impp | 13.48 A | 13.47 A | 0.1% |
| TcVoc | -0.22 %/°C | -0.24 %/°C | ±0.020 %/°C |
| TcPmax | -0.26 %/°C | -0.29 %/°C | ±0.030 %/°C |
645 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 58.74 V | 57.9 V | 1.4% |
| Vmpp | 48.61 V | 48.05 V | 1.2% |
| Isc | 14.21 A | 14.19 A | 0.1% |
| Impp | 13.48 A | 13.44 A | 0.3% |
| TcVoc | -0.22 %/°C | -0.25 %/°C | ±0.030 %/°C |
| TcPmax | -0.26 %/°C | -0.29 %/°C | ±0.030 %/°C |
640 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 58.74 V | 57.4 V | 2.3% |
| Vmpp | 48.61 V | 48.22 V | 0.8% |
| Isc | 14.21 A | 13.86 A | 2.5% |
| Impp | 13.48 A | 13.28 A | 1.5% |
| TcVoc | -0.22 %/°C | -0.24 %/°C | ±0.020 %/°C |
| TcPmax | -0.26 %/°C | -0.28 %/°C | ±0.020 %/°C |
String Compatibility Calculator
Verify the replacement panel works with your inverter
Panel Matcher
Find all compatible panels for a specific inverter
Already have panels?
Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.
How the Algorithm Works
Learn how panels are scored and matched
Voc
58.74 V
Vmpp
48.61 V
Isc
14.21 A
Impp
13.48 A
TcVoc
-0.22 %/°C
TcPmax
-0.26 %/°C
Pmax
655 W
Cells
156
Bifaciality
70%
Length
2465 mm
Width
1134 mm
Thickness
30 mm
Weight
34.7 kg
The Aiko Solar AIKO-A655-MAH78Dw is a 655 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.
Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.
| Model | Power | Voc | Isc |
|---|---|---|---|
| AIKO-A660-MAH78Dw | 660 W | 58.8 V | 14.28 A |
| AIKO-A665-MAH78Dw | 665 W | 58.86 V | 14.35 A |
| AIKO-A670-MAH78Dw | 670 W | 58.92 V | 14.42 A |
| AIKO-A675-MAH78Dw | 675 W | 58.98 V | 14.49 A |
| AIKO-A680-MAH78Dw | 680 W | 59.04 V | 14.56 A |
The most critical specs to match are: cell count (must be exactly 156), Voc close to 58.74 V (within ±5%), and temperature coefficient TcVoc close to -0.22%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.
A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.
If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original Aiko Solar AIKO-A655-MAH78Dw.