655 W ABC solar panel with 144 cells. Voc 55 V · Isc 15.33 A · TcVoc -0.22%/°C.
Select the panel you want to replace
58 panels found · 4281 panels excluded
650 W
ABC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 55 V | 54.9 V | 0.2% |
| Vmpp | 44.89 V | 44.79 V | 0.2% |
| Isc | 15.33 A | 15.27 A | 0.4% |
| Impp | 14.6 A | 14.52 A | 0.5% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
660 W
ABC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 55 V | 55.1 V | 0.2% |
| Vmpp | 44.89 V | 44.99 V | 0.2% |
| Isc | 15.33 A | 15.39 A | 0.4% |
| Impp | 14.6 A | 14.68 A | 0.5% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
665 W
IBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 55 V | 54.84 V | 0.3% |
| Vmpp | 44.89 V | 45.24 V | 0.8% |
| Isc | 15.33 A | 15.33 A | 0.0% |
| Impp | 14.6 A | 14.7 A | 0.7% |
| TcVoc | -0.22 %/°C | -0.2 %/°C | ±0.020 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
665 W
HIBC (HJT)| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 55 V | 55.1 V | 0.2% |
| Vmpp | 44.89 V | 45.51 V | 1.4% |
| Isc | 15.33 A | 15.28 A | 0.3% |
| Impp | 14.6 A | 14.61 A | 0.1% |
| TcVoc | -0.22 %/°C | -0.21 %/°C | ±0.010 %/°C |
| TcPmax | -0.26 %/°C | -0.24 %/°C | ±0.020 %/°C |
660 W
IBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 55 V | 54.61 V | 0.7% |
| Vmpp | 44.89 V | 45.12 V | 0.5% |
| Isc | 15.33 A | 15.28 A | 0.3% |
| Impp | 14.6 A | 14.63 A | 0.2% |
| TcVoc | -0.22 %/°C | -0.2 %/°C | ±0.020 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
670 W
HIBC (HJT)| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 55 V | 55.2 V | 0.4% |
| Vmpp | 44.89 V | 45.61 V | 1.6% |
| Isc | 15.33 A | 15.36 A | 0.2% |
| Impp | 14.6 A | 14.69 A | 0.6% |
| TcVoc | -0.22 %/°C | -0.21 %/°C | ±0.010 %/°C |
| TcPmax | -0.26 %/°C | -0.24 %/°C | ±0.020 %/°C |
670 W
ABC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 55 V | 54.26 V | 1.3% |
| Vmpp | 44.89 V | 45.32 V | 1.0% |
| Isc | 15.33 A | 15.51 A | 1.2% |
| Impp | 14.6 A | 14.79 A | 1.3% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
665 W
ABC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 55 V | 54.16 V | 1.5% |
| Vmpp | 44.89 V | 45.22 V | 0.7% |
| Isc | 15.33 A | 15.45 A | 0.8% |
| Impp | 14.6 A | 14.71 A | 0.8% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
675 W
ABC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 55 V | 54.36 V | 1.2% |
| Vmpp | 44.89 V | 45.42 V | 1.2% |
| Isc | 15.33 A | 15.57 A | 1.6% |
| Impp | 14.6 A | 14.87 A | 1.8% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
665 W
HPBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 55 V | 54.52 V | 0.9% |
| Vmpp | 44.89 V | 45.17 V | 0.6% |
| Isc | 15.33 A | 15.38 A | 0.3% |
| Impp | 14.6 A | 14.72 A | 0.8% |
| TcVoc | -0.22 %/°C | -0.2 %/°C | ±0.020 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
670 W
HPBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 55 V | 54.62 V | 0.7% |
| Vmpp | 44.89 V | 45.27 V | 0.8% |
| Isc | 15.33 A | 15.46 A | 0.8% |
| Impp | 14.6 A | 14.8 A | 1.4% |
| TcVoc | -0.22 %/°C | -0.2 %/°C | ±0.020 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
665 W
HPBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 55 V | 54.52 V | 0.9% |
| Vmpp | 44.89 V | 45.17 V | 0.6% |
| Isc | 15.33 A | 15.35 A | 0.1% |
| Impp | 14.6 A | 14.72 A | 0.8% |
| TcVoc | -0.22 %/°C | -0.2 %/°C | ±0.020 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
String Compatibility Calculator
Verify the replacement panel works with your inverter
Panel Matcher
Find all compatible panels for a specific inverter
Already have panels?
Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.
How the Algorithm Works
Learn how panels are scored and matched
Voc
55 V
Vmpp
44.89 V
Isc
15.33 A
Impp
14.6 A
TcVoc
-0.22 %/°C
TcPmax
-0.26 %/°C
Pmax
655 W
Cells
144
Bifaciality
40%
Length
2382 mm
Width
1134 mm
Thickness
30 mm
Weight
32.2 kg
The Aiko Solar AIKO-A655-MDE72Dw is a 655 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.
Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.
| Model | Power | Voc | Isc |
|---|---|---|---|
| AIKO-A650-MDE72Dw | 650 W | 54.9 V | 15.27 A |
| AIKO-A660-MDE72Dw | 660 W | 55.1 V | 15.39 A |
| AIKO-A665-MDE72Dw | 665 W | 54.16 V | 15.45 A |
| AIKO-A670-MDE72Dw | 670 W | 54.26 V | 15.51 A |
| AIKO-A675-MDE72Dw | 675 W | 54.36 V | 15.57 A |
| AIKO-A680-MDE72Dw | 680 W | 54.46 V | 15.63 A |
| AIKO-A685-MDE72Dw | 685 W | 54.56 V | 15.69 A |
| AIKO-A690-MDE72Dw | 690 W | 54.66 V | 15.75 A |
The most critical specs to match are: cell count (must be exactly 144), Voc close to 55 V (within ±5%), and temperature coefficient TcVoc close to -0.22%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.
A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.
If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original Aiko Solar AIKO-A655-MDE72Dw.