670 W ABC solar panel with 132 cells. Voc 49.6 V · Isc 16.71 A · TcVoc -0.22%/°C.
Select the panel you want to replace
73 panels found · 4266 panels excluded
675 W
ABC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.6 V | 49.7 V | 0.2% |
| Vmpp | 41.44 V | 41.52 V | 0.2% |
| Isc | 16.71 A | 16.78 A | 0.4% |
| Impp | 16.17 A | 16.26 A | 0.6% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
665 W
ABC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.6 V | 49.5 V | 0.2% |
| Vmpp | 41.44 V | 41.36 V | 0.2% |
| Isc | 16.71 A | 16.64 A | 0.4% |
| Impp | 16.17 A | 16.08 A | 0.6% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
660 W
ABC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.6 V | 49.4 V | 0.4% |
| Vmpp | 41.44 V | 41.28 V | 0.4% |
| Isc | 16.71 A | 16.57 A | 0.8% |
| Impp | 16.17 A | 15.99 A | 1.1% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
680 W
ABC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.6 V | 49.8 V | 0.4% |
| Vmpp | 41.44 V | 41.6 V | 0.4% |
| Isc | 16.71 A | 16.85 A | 0.8% |
| Impp | 16.17 A | 16.35 A | 1.1% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
650 W
ABC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.6 V | 49.7 V | 0.2% |
| Vmpp | 41.44 V | 40.68 V | 1.8% |
| Isc | 16.71 A | 16.64 A | 0.4% |
| Impp | 16.17 A | 15.98 A | 1.2% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
655 W
ABC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.6 V | 49.3 V | 0.6% |
| Vmpp | 41.44 V | 41.2 V | 0.6% |
| Isc | 16.71 A | 16.5 A | 1.3% |
| Impp | 16.17 A | 15.9 A | 1.7% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
680 W
HJT| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.6 V | 49.51 V | 0.2% |
| Vmpp | 41.44 V | 42.08 V | 1.5% |
| Isc | 16.71 A | 17.13 A | 2.5% |
| Impp | 16.17 A | 16.16 A | 0.1% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.24 %/°C | ±0.020 %/°C |
680 W
HJT| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.6 V | 49.47 V | 0.3% |
| Vmpp | 41.44 V | 41.48 V | 0.1% |
| Isc | 16.71 A | 17.48 A | 4.6% |
| Impp | 16.17 A | 16.41 A | 1.5% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.24 %/°C | ±0.020 %/°C |
655 W
IBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.6 V | 49.64 V | 0.1% |
| Vmpp | 41.44 V | 40.93 V | 1.2% |
| Isc | 16.71 A | 16.78 A | 0.4% |
| Impp | 16.17 A | 16 A | 1.1% |
| TcVoc | -0.22 %/°C | -0.2 %/°C | ±0.020 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
685 W
HJT| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.6 V | 49.56 V | 0.1% |
| Vmpp | 41.44 V | 41.56 V | 0.3% |
| Isc | 16.71 A | 17.56 A | 5.1% |
| Impp | 16.17 A | 16.5 A | 2.0% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.24 %/°C | ±0.020 %/°C |
650 W
IBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.6 V | 49.54 V | 0.1% |
| Vmpp | 41.44 V | 40.83 V | 1.5% |
| Isc | 16.71 A | 16.7 A | 0.1% |
| Impp | 16.17 A | 15.92 A | 1.5% |
| TcVoc | -0.22 %/°C | -0.2 %/°C | ±0.020 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
675 W
HJT| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.6 V | 49.38 V | 0.4% |
| Vmpp | 41.44 V | 41.41 V | 0.1% |
| Isc | 16.71 A | 17.4 A | 4.1% |
| Impp | 16.17 A | 16.32 A | 0.9% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.24 %/°C | ±0.020 %/°C |
String Compatibility Calculator
Verify the replacement panel works with your inverter
Panel Matcher
Find all compatible panels for a specific inverter
Already have panels?
Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.
How the Algorithm Works
Learn how panels are scored and matched
Voc
49.6 V
Vmpp
41.44 V
Isc
16.71 A
Impp
16.17 A
TcVoc
-0.22 %/°C
TcPmax
-0.26 %/°C
Pmax
670 W
Cells
132
Bifaciality
85%
Length
2382 mm
Width
1134 mm
Thickness
30 mm
Weight
32.5 kg
The Aiko Solar AIKO-A670-GRH66Dw is a 670 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.
Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.
| Model | Power | Voc | Isc |
|---|---|---|---|
| AIKO-A655-GRH66Dw | 655 W | 49.3 V | 16.5 A |
| AIKO-A660-GRH66Dw | 660 W | 49.4 V | 16.57 A |
| AIKO-A665-GRH66Dw | 665 W | 49.5 V | 16.64 A |
| AIKO-A675-GRH66Dw | 675 W | 49.7 V | 16.78 A |
| AIKO-A680-GRH66Dw | 680 W | 49.8 V | 16.85 A |
The most critical specs to match are: cell count (must be exactly 132), Voc close to 49.6 V (within ±5%), and temperature coefficient TcVoc close to -0.22%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.
A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.
If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original Aiko Solar AIKO-A670-GRH66Dw.