315 W PERC solar panel with 120 cells. Voc 40.13 V · Isc 10.03 A · TcVoc -0.29%/°C.
Select the panel you want to replace
7 panels found · 4332 panels excluded
320 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 40.13 V | 40.25 V | 0.3% |
| Vmpp | 32.97 V | 33.21 V | 0.7% |
| Isc | 10.03 A | 10.11 A | 0.8% |
| Impp | 9.56 A | 9.64 A | 0.8% |
| TcVoc | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
| TcPmax | -0.39 %/°C | -0.39 %/°C | ±0.000 %/°C |
325 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 40.13 V | 40.37 V | 0.6% |
| Vmpp | 32.97 V | 33.45 V | 1.5% |
| Isc | 10.03 A | 10.18 A | 1.5% |
| Impp | 9.56 A | 9.73 A | 1.8% |
| TcVoc | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
| TcPmax | -0.39 %/°C | -0.39 %/°C | ±0.000 %/°C |
325 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 40.13 V | 40.4 V | 0.7% |
| Vmpp | 32.97 V | 33.5 V | 1.6% |
| Isc | 10.03 A | 10.28 A | 2.5% |
| Impp | 9.56 A | 9.71 A | 1.6% |
| TcVoc | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
| TcPmax | -0.39 %/°C | -0.39 %/°C | ±0.000 %/°C |
330 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 40.13 V | 40.49 V | 0.9% |
| Vmpp | 32.97 V | 33.74 V | 2.3% |
| Isc | 10.03 A | 10.25 A | 2.2% |
| Impp | 9.56 A | 9.79 A | 2.4% |
| TcVoc | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
| TcPmax | -0.39 %/°C | -0.39 %/°C | ±0.000 %/°C |
330 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 40.13 V | 40.6 V | 1.2% |
| Vmpp | 32.97 V | 33.7 V | 2.2% |
| Isc | 10.03 A | 10.35 A | 3.2% |
| Impp | 9.56 A | 9.8 A | 2.5% |
| TcVoc | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
| TcPmax | -0.39 %/°C | -0.39 %/°C | ±0.000 %/°C |
335 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 40.13 V | 40.65 V | 1.3% |
| Vmpp | 32.97 V | 33.98 V | 3.1% |
| Isc | 10.03 A | 10.31 A | 2.8% |
| Impp | 9.56 A | 9.87 A | 3.2% |
| TcVoc | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
| TcPmax | -0.39 %/°C | -0.39 %/°C | ±0.000 %/°C |
335 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 40.13 V | 40.8 V | 1.7% |
| Vmpp | 32.97 V | 33.9 V | 2.8% |
| Isc | 10.03 A | 10.42 A | 3.9% |
| Impp | 9.56 A | 9.89 A | 3.5% |
| TcVoc | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
| TcPmax | -0.39 %/°C | -0.39 %/°C | ±0.000 %/°C |
String Compatibility Calculator
Verify the replacement panel works with your inverter
Panel Matcher
Find all compatible panels for a specific inverter
Already have panels?
Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.
How the Algorithm Works
Learn how panels are scored and matched
Voc
40.13 V
Vmpp
32.97 V
Isc
10.03 A
Impp
9.56 A
TcVoc
-0.29 %/°C
TcPmax
-0.39 %/°C
Pmax
315 W
Cells
120
Length
1684 mm
Width
1002 mm
Thickness
35 mm
Weight
19 kg
The AXITEC AC-315MH/120V is a 315 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.
Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.
| Model | Power | Voc | Isc |
|---|---|---|---|
| AC-320MH/120V | 320 W | 40.25 V | 10.11 A |
| AC-325MH/120V | 325 W | 40.37 V | 10.18 A |
| AC-330MH/120V | 330 W | 40.49 V | 10.25 A |
| AC-335MH/120V | 335 W | 40.65 V | 10.31 A |
| AC-340MH/120V | 340 W | 40.82 V | 10.39 A |
The most critical specs to match are: cell count (must be exactly 120), Voc close to 40.13 V (within ±5%), and temperature coefficient TcVoc close to -0.29%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.
A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.
If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original AXITEC AC-315MH/120V.