600 W TOPCon solar panel with 144 cells. Voc 51.8 V · Isc 14.54 A · TcVoc -0.25%/°C.
Select the panel you want to replace
132 panels found · 4207 panels excluded
600 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.8 V | 51.8 V | 0.0% |
| Vmpp | 44 V | 44 V | 0.0% |
| Isc | 14.54 A | 14.54 A | 0.0% |
| Impp | 13.64 A | 13.64 A | 0.0% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
595 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.8 V | 51.6 V | 0.4% |
| Vmpp | 44 V | 43.8 V | 0.5% |
| Isc | 14.54 A | 14.48 A | 0.4% |
| Impp | 13.64 A | 13.59 A | 0.4% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
605 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.8 V | 52 V | 0.4% |
| Vmpp | 44 V | 44.2 V | 0.5% |
| Isc | 14.54 A | 14.6 A | 0.4% |
| Impp | 13.64 A | 13.69 A | 0.4% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
605 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.8 V | 52 V | 0.4% |
| Vmpp | 44 V | 44.2 V | 0.5% |
| Isc | 14.54 A | 14.6 A | 0.4% |
| Impp | 13.64 A | 13.69 A | 0.4% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
600 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.8 V | 51.8 V | 0.0% |
| Vmpp | 44 V | 44 V | 0.0% |
| Isc | 14.54 A | 14.54 A | 0.0% |
| Impp | 13.64 A | 13.64 A | 0.0% |
| TcVoc | -0.25 %/°C | -0.23 %/°C | ±0.020 %/°C |
| TcPmax | -0.29 %/°C | -0.28 %/°C | ±0.010 %/°C |
590 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.8 V | 51.95 V | 0.3% |
| Vmpp | 44 V | 43.67 V | 0.7% |
| Isc | 14.54 A | 14.18 A | 2.5% |
| Impp | 13.64 A | 13.51 A | 1.0% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
585 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.8 V | 51.73 V | 0.1% |
| Vmpp | 44 V | 43.51 V | 1.1% |
| Isc | 14.54 A | 14.11 A | 3.0% |
| Impp | 13.64 A | 13.45 A | 1.4% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
595 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.8 V | 52.16 V | 0.7% |
| Vmpp | 44 V | 43.88 V | 0.3% |
| Isc | 14.54 A | 14.25 A | 2.0% |
| Impp | 13.64 A | 13.56 A | 0.6% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
595 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.8 V | 51.81 V | 0.0% |
| Vmpp | 44 V | 43.02 V | 2.2% |
| Isc | 14.54 A | 14.56 A | 0.1% |
| Impp | 13.64 A | 13.83 A | 1.4% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.3 %/°C | ±0.010 %/°C |
590 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.8 V | 51.6 V | 0.4% |
| Vmpp | 44 V | 43.4 V | 1.4% |
| Isc | 14.54 A | 14.34 A | 1.4% |
| Impp | 13.64 A | 13.59 A | 0.4% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.3 %/°C | ±0.010 %/°C |
610 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.8 V | 52.2 V | 0.8% |
| Vmpp | 44 V | 44.4 V | 0.9% |
| Isc | 14.54 A | 14.66 A | 0.8% |
| Impp | 13.64 A | 13.74 A | 0.7% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
610 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.8 V | 52.2 V | 0.8% |
| Vmpp | 44 V | 44.4 V | 0.9% |
| Isc | 14.54 A | 14.66 A | 0.8% |
| Impp | 13.64 A | 13.74 A | 0.7% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
String Compatibility Calculator
Verify the replacement panel works with your inverter
Panel Matcher
Find all compatible panels for a specific inverter
Already have panels?
Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.
How the Algorithm Works
Learn how panels are scored and matched
Voc
51.8 V
Vmpp
44 V
Isc
14.54 A
Impp
13.64 A
TcVoc
-0.25 %/°C
TcPmax
-0.29 %/°C
Pmax
600 W
Cells
144
Length
2382 mm
Width
1134 mm
Thickness
30 mm
Weight
32.8 kg
The Canadian Solar CS6.1-72TD-600H is a 600 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.
Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.
| Model | Power | Voc | Isc |
|---|---|---|---|
| CS6.1-72TD-605H | 605 W | 52 V | 14.6 A |
| CS6.1-72TD-610H | 610 W | 52.2 V | 14.66 A |
| CS6.1-72TD-615H | 615 W | 52.4 V | 14.72 A |
| CS6.1-72TD-620H | 620 W | 52.6 V | 14.78 A |
| CS6.1-72TD-625H | 625 W | 52.8 V | 14.84 A |
| CS6.1-72TD-630H | 630 W | 53 V | 14.9 A |
The most critical specs to match are: cell count (must be exactly 144), Voc close to 51.8 V (within ±5%), and temperature coefficient TcVoc close to -0.25%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.
A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.
If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original Canadian Solar CS6.1-72TD-600H.