480 W TOPCon solar panel with 96 cells. Voc 35.7 V · Isc 16.3 A · TcVoc -0.25%/°C.
Select the panel you want to replace
Voc
35.7 V
Vmpp
30.5 V
Isc
16.3 A
Impp
15.74 A
TcVoc
-0.25 %/°C
TcPmax
-0.29 %/°C
Pmax
480 W
Cells
96
Bifaciality
80%
The DAH Solar HE-DHN-48Z20/DG-FS(BW)-480W is a 480 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.
Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.
| Model | Power | Voc | Isc |
|---|---|---|---|
| 465 W | 35.4 V | 16.18 A | |
| 470 W | 35.5 V | 16.22 A | |
| 475 W | 35.6 V | 16.26 A | |
| 485 W | 35.8 V | 16.34 A |
The most critical specs to match are: cell count (must be exactly 96), Voc close to 35.7 V (within ±5%), and temperature coefficient TcVoc close to -0.25%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.
A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.
If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original DAH Solar HE-DHN-48Z20/DG-FS(BW)-480W.