470 W TOPCon solar panel with 96 cells. Voc 35.89 V · Isc 16.43 A · TcVoc -0.25%/°C.
Select the panel you want to replace
85 panels found · 4254 panels excluded
465 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 35.89 V | 35.78 V | 0.3% |
| Vmpp | 30.56 V | 30.5 V | 0.2% |
| Isc | 16.43 A | 16.32 A | 0.7% |
| Impp | 15.38 A | 15.25 A | 0.8% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.28 %/°C | -0.28 %/°C | ±0.000 %/°C |
460 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 35.89 V | 35.68 V | 0.6% |
| Vmpp | 30.56 V | 30.41 V | 0.5% |
| Isc | 16.43 A | 16.22 A | 1.3% |
| Impp | 15.38 A | 15.13 A | 1.6% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.28 %/°C | -0.28 %/°C | ±0.000 %/°C |
460 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 35.89 V | 36 V | 0.3% |
| Vmpp | 30.56 V | 30.1 V | 1.5% |
| Isc | 16.43 A | 16.32 A | 0.7% |
| Impp | 15.38 A | 15.28 A | 0.7% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.28 %/°C | -0.29 %/°C | ±0.010 %/°C |
455 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 35.89 V | 35.95 V | 0.2% |
| Vmpp | 30.56 V | 30.44 V | 0.4% |
| Isc | 16.43 A | 15.98 A | 2.7% |
| Impp | 15.38 A | 14.95 A | 2.8% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.28 %/°C | -0.3 %/°C | ±0.020 %/°C |
455 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 35.89 V | 35.8 V | 0.3% |
| Vmpp | 30.56 V | 29.9 V | 2.2% |
| Isc | 16.43 A | 16.23 A | 1.2% |
| Impp | 15.38 A | 15.22 A | 1.0% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.28 %/°C | -0.29 %/°C | ±0.010 %/°C |
465 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 35.89 V | 36.2 V | 0.9% |
| Vmpp | 30.56 V | 30.3 V | 0.9% |
| Isc | 16.43 A | 16.38 A | 0.3% |
| Impp | 15.38 A | 15.35 A | 0.2% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.28 %/°C | -0.29 %/°C | ±0.010 %/°C |
450 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 35.89 V | 35.91 V | 0.1% |
| Vmpp | 30.56 V | 30.04 V | 1.7% |
| Isc | 16.43 A | 15.73 A | 4.3% |
| Impp | 15.38 A | 14.98 A | 2.6% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.28 %/°C | -0.29 %/°C | ±0.010 %/°C |
470 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 35.89 V | 36.4 V | 1.4% |
| Vmpp | 30.56 V | 30.5 V | 0.2% |
| Isc | 16.43 A | 16.45 A | 0.1% |
| Impp | 15.38 A | 15.41 A | 0.2% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.28 %/°C | -0.29 %/°C | ±0.010 %/°C |
460 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 35.89 V | 36.22 V | 0.9% |
| Vmpp | 30.56 V | 30.51 V | 0.2% |
| Isc | 16.43 A | 15.93 A | 3.0% |
| Impp | 15.38 A | 15.08 A | 2.0% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.28 %/°C | -0.29 %/°C | ±0.010 %/°C |
455 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 35.89 V | 36.08 V | 0.5% |
| Vmpp | 30.56 V | 30.28 V | 0.9% |
| Isc | 16.43 A | 15.78 A | 4.0% |
| Impp | 15.38 A | 15.03 A | 2.3% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.28 %/°C | -0.29 %/°C | ±0.010 %/°C |
450 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 35.89 V | 35.93 V | 0.1% |
| Vmpp | 30.56 V | 29.68 V | 2.9% |
| Isc | 16.43 A | 16.04 A | 2.4% |
| Impp | 15.38 A | 15.17 A | 1.4% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.28 %/°C | -0.29 %/°C | ±0.010 %/°C |
450 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 35.89 V | 35.75 V | 0.4% |
| Vmpp | 30.56 V | 30.19 V | 1.2% |
| Isc | 16.43 A | 15.95 A | 2.9% |
| Impp | 15.38 A | 14.91 A | 3.1% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.28 %/°C | -0.3 %/°C | ±0.020 %/°C |
String Compatibility Calculator
Verify the replacement panel works with your inverter
Panel Matcher
Find all compatible panels for a specific inverter
Already have panels?
Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.
How the Algorithm Works
Learn how panels are scored and matched
Voc
35.89 V
Vmpp
30.56 V
Isc
16.43 A
Impp
15.38 A
TcVoc
-0.25 %/°C
TcPmax
-0.28 %/°C
Pmax
470 W
Cells
96
Length
1762 mm
Width
1134 mm
Thickness
30 mm
Weight
21.6 kg
The DAS Solar DAS-DH96NE.A-470 is a 470 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.
Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.
| Model | Power | Voc | Isc |
|---|---|---|---|
| DAS-DH96NE.A-445 | 445 W | 35.11 V | 16.01 A |
| DAS-DH96NE.A-450 | 450 W | 35.3 V | 16.08 A |
| DAS-DH96NE.A-455 | 455 W | 35.5 V | 16.16 A |
| DAS-DH96NE.A-460 | 460 W | 35.68 V | 16.22 A |
| DAS-DH96NE.A-465 | 465 W | 35.78 V | 16.32 A |
The most critical specs to match are: cell count (must be exactly 96), Voc close to 35.89 V (within ±5%), and temperature coefficient TcVoc close to -0.25%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.
A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.
If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original DAS Solar DAS-DH96NE.A-470.