495 W TOPCon solar panel with 108 cells. Voc 45.46 V · Isc 13.99 A · TcVoc -0.25%/°C.
Select the panel you want to replace
Voc
45.46 V
Vmpp
37.68 V
Isc
13.99 A
Impp
13.14 A
TcVoc
-0.25 %/°C
TcPmax
-0.29 %/°C
Pmax
495 W
Cells
108
Bifaciality
80%
The DMEGC DM495M10-66HSW is a 495 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.
Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.
| Model | Power | Voc | Isc |
|---|---|---|---|
| DM500M10-66HSW | 500 W | 45.6 V | 14.07 A |
| DM505M10-66HSW | 505 W | 45.73 V | 14.14 A |
| DM510M10-66HSW | 510 W | 45.87 V | 14.21 A |
The most critical specs to match are: cell count (must be exactly 108), Voc close to 45.46 V (within ±5%), and temperature coefficient TcVoc close to -0.25%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.
A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.
If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original DMEGC DM495M10-66HSW.