595 W TOPCon solar panel with 156 cells. Voc 54 V · Isc 14.12 A · TcVoc -0.269%/°C.
Select the panel you want to replace
23 panels found · 4316 panels excluded
600 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 54 V | 54.15 V | 0.3% |
| Vmpp | 44.88 V | 45.03 V | 0.3% |
| Isc | 14.12 A | 14.19 A | 0.5% |
| Impp | 13.27 A | 13.33 A | 0.5% |
| TcVoc | -0.269 %/°C | -0.269 %/°C | ±0.000 %/°C |
| TcPmax | -0.335 %/°C | -0.335 %/°C | ±0.000 %/°C |
590 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 54 V | 53.85 V | 0.3% |
| Vmpp | 44.88 V | 44.73 V | 0.3% |
| Isc | 14.12 A | 14.05 A | 0.5% |
| Impp | 13.27 A | 13.2 A | 0.5% |
| TcVoc | -0.269 %/°C | -0.269 %/°C | ±0.000 %/°C |
| TcPmax | -0.335 %/°C | -0.335 %/°C | ±0.000 %/°C |
605 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 54 V | 54.3 V | 0.6% |
| Vmpp | 44.88 V | 45.18 V | 0.7% |
| Isc | 14.12 A | 14.26 A | 1.0% |
| Impp | 13.27 A | 13.39 A | 0.9% |
| TcVoc | -0.269 %/°C | -0.269 %/°C | ±0.000 %/°C |
| TcPmax | -0.335 %/°C | -0.335 %/°C | ±0.000 %/°C |
595 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 54 V | 54.03 V | 0.1% |
| Vmpp | 44.88 V | 45.41 V | 1.2% |
| Isc | 14.12 A | 13.99 A | 0.9% |
| Impp | 13.27 A | 13.11 A | 1.2% |
| TcVoc | -0.269 %/°C | -0.26 %/°C | ±0.009 %/°C |
| TcPmax | -0.335 %/°C | -0.34 %/°C | ±0.005 %/°C |
595 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 54 V | 54.03 V | 0.1% |
| Vmpp | 44.88 V | 45.41 V | 1.2% |
| Isc | 14.12 A | 13.99 A | 0.9% |
| Impp | 13.27 A | 13.11 A | 1.2% |
| TcVoc | -0.269 %/°C | -0.26 %/°C | ±0.009 %/°C |
| TcPmax | -0.335 %/°C | -0.34 %/°C | ±0.005 %/°C |
590 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 54 V | 53.83 V | 0.3% |
| Vmpp | 44.88 V | 45.21 V | 0.7% |
| Isc | 14.12 A | 13.93 A | 1.3% |
| Impp | 13.27 A | 13.06 A | 1.6% |
| TcVoc | -0.269 %/°C | -0.26 %/°C | ±0.009 %/°C |
| TcPmax | -0.335 %/°C | -0.34 %/°C | ±0.005 %/°C |
590 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 54 V | 53.83 V | 0.3% |
| Vmpp | 44.88 V | 45.21 V | 0.7% |
| Isc | 14.12 A | 13.93 A | 1.3% |
| Impp | 13.27 A | 13.06 A | 1.6% |
| TcVoc | -0.269 %/°C | -0.26 %/°C | ±0.009 %/°C |
| TcPmax | -0.335 %/°C | -0.34 %/°C | ±0.005 %/°C |
600 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 54 V | 54.23 V | 0.4% |
| Vmpp | 44.88 V | 45.61 V | 1.6% |
| Isc | 14.12 A | 14.05 A | 0.5% |
| Impp | 13.27 A | 13.16 A | 0.8% |
| TcVoc | -0.269 %/°C | -0.26 %/°C | ±0.009 %/°C |
| TcPmax | -0.335 %/°C | -0.34 %/°C | ±0.005 %/°C |
585 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 54 V | 53.63 V | 0.7% |
| Vmpp | 44.88 V | 45.01 V | 0.3% |
| Isc | 14.12 A | 13.87 A | 1.8% |
| Impp | 13.27 A | 13.01 A | 2.0% |
| TcVoc | -0.269 %/°C | -0.26 %/°C | ±0.009 %/°C |
| TcPmax | -0.335 %/°C | -0.34 %/°C | ±0.005 %/°C |
585 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 54 V | 53.63 V | 0.7% |
| Vmpp | 44.88 V | 45.01 V | 0.3% |
| Isc | 14.12 A | 13.87 A | 1.8% |
| Impp | 13.27 A | 13.01 A | 2.0% |
| TcVoc | -0.269 %/°C | -0.26 %/°C | ±0.009 %/°C |
| TcPmax | -0.335 %/°C | -0.34 %/°C | ±0.005 %/°C |
600 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 54 V | 54.23 V | 0.4% |
| Vmpp | 44.88 V | 45.61 V | 1.6% |
| Isc | 14.12 A | 14.05 A | 0.5% |
| Impp | 13.27 A | 13.16 A | 0.8% |
| TcVoc | -0.269 %/°C | -0.26 %/°C | ±0.009 %/°C |
| TcPmax | -0.335 %/°C | -0.34 %/°C | ±0.005 %/°C |
590 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 54 V | 53.87 V | 0.2% |
| Vmpp | 44.88 V | 45.34 V | 1.0% |
| Isc | 14.12 A | 13.9 A | 1.6% |
| Impp | 13.27 A | 13.02 A | 1.9% |
| TcVoc | -0.269 %/°C | -0.25 %/°C | ±0.019 %/°C |
| TcPmax | -0.335 %/°C | -0.34 %/°C | ±0.005 %/°C |
String Compatibility Calculator
Verify the replacement panel works with your inverter
Panel Matcher
Find all compatible panels for a specific inverter
Already have panels?
Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.
How the Algorithm Works
Learn how panels are scored and matched
Voc
54 V
Vmpp
44.88 V
Isc
14.12 A
Impp
13.27 A
TcVoc
-0.269 %/°C
TcPmax
-0.335 %/°C
Pmax
595 W
Cells
156
Bifaciality
70%
Length
2465 mm
Width
1134 mm
Thickness
30 mm
Weight
33.5 kg
The DMEGC DM595M10-B78HSW is a 595 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.
Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.
| Model | Power | Voc | Isc |
|---|---|---|---|
| DM590M10-B78HSW | 590 W | 53.85 V | 14.05 A |
| DM600M10-B78HSW | 600 W | 54.15 V | 14.19 A |
| DM605M10-B78HSW | 605 W | 54.3 V | 14.26 A |
The most critical specs to match are: cell count (must be exactly 156), Voc close to 54 V (within ±5%), and temperature coefficient TcVoc close to -0.269%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.
A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.
If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original DMEGC DM595M10-B78HSW.