635 W TOPCon solar panel with 132 cells. Voc 48.88 V · Isc 16.13 A · TcVoc -0.25%/°C.
Select the panel you want to replace
188 panels found · 4151 panels excluded
625 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.88 V | 48.83 V | 0.1% |
| Vmpp | 41.5 V | 41.51 V | 0.0% |
| Isc | 16.13 A | 16 A | 0.8% |
| Impp | 15.3 A | 15.06 A | 1.6% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
615 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.88 V | 48.89 V | 0.0% |
| Vmpp | 41.5 V | 41.43 V | 0.2% |
| Isc | 16.13 A | 16.02 A | 0.7% |
| Impp | 15.3 A | 14.84 A | 3.0% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
630 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.88 V | 48.8 V | 0.2% |
| Vmpp | 41.5 V | 41.6 V | 0.2% |
| Isc | 16.13 A | 16.2 A | 0.4% |
| Impp | 15.3 A | 15.16 A | 0.9% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
620 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.88 V | 49.04 V | 0.3% |
| Vmpp | 41.5 V | 41.56 V | 0.1% |
| Isc | 16.13 A | 16.11 A | 0.1% |
| Impp | 15.3 A | 14.92 A | 2.5% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
620 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.88 V | 48.78 V | 0.2% |
| Vmpp | 41.5 V | 41.46 V | 0.1% |
| Isc | 16.13 A | 15.89 A | 1.5% |
| Impp | 15.3 A | 14.96 A | 2.2% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
625 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.88 V | 48.6 V | 0.6% |
| Vmpp | 41.5 V | 41.4 V | 0.2% |
| Isc | 16.13 A | 16.14 A | 0.1% |
| Impp | 15.3 A | 15.11 A | 1.2% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
645 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.88 V | 48.7 V | 0.4% |
| Vmpp | 41.5 V | 41.6 V | 0.2% |
| Isc | 16.13 A | 16.38 A | 1.5% |
| Impp | 15.3 A | 15.5 A | 1.3% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
650 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.88 V | 48.8 V | 0.2% |
| Vmpp | 41.5 V | 41.7 V | 0.5% |
| Isc | 16.13 A | 16.42 A | 1.8% |
| Impp | 15.3 A | 15.59 A | 1.9% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
655 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.88 V | 48.9 V | 0.0% |
| Vmpp | 41.5 V | 41.8 V | 0.7% |
| Isc | 16.13 A | 16.46 A | 2.0% |
| Impp | 15.3 A | 15.67 A | 2.4% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
630 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.88 V | 48.9 V | 0.0% |
| Vmpp | 41.5 V | 40.7 V | 1.9% |
| Isc | 16.13 A | 16.18 A | 0.3% |
| Impp | 15.3 A | 15.48 A | 1.2% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
640 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.88 V | 49.15 V | 0.6% |
| Vmpp | 41.5 V | 41.72 V | 0.5% |
| Isc | 16.13 A | 16.17 A | 0.2% |
| Impp | 15.3 A | 15.34 A | 0.3% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
635 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.88 V | 48.88 V | 0.0% |
| Vmpp | 41.5 V | 41 V | 1.2% |
| Isc | 16.13 A | 16.29 A | 1.0% |
| Impp | 15.3 A | 15.49 A | 1.2% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.28 %/°C | ±0.010 %/°C |
String Compatibility Calculator
Verify the replacement panel works with your inverter
Panel Matcher
Find all compatible panels for a specific inverter
Already have panels?
Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.
How the Algorithm Works
Learn how panels are scored and matched
Voc
48.88 V
Vmpp
41.5 V
Isc
16.13 A
Impp
15.3 A
TcVoc
-0.25 %/°C
TcPmax
-0.29 %/°C
Pmax
635 W
Cells
132
Bifaciality
80%
Length
2382 mm
Width
1134 mm
Thickness
30 mm
Weight
32.5 kg
The GCL-NT12R/66GDF 635 is a 635 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.
Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.
| Model | Power | Voc | Isc |
|---|---|---|---|
| GCL-NT12R/66GDF 640 | 640 W | 49.15 V | 16.17 A |
| GCL-NT12R/66GDF 645 | 645 W | 49.4 V | 16.21 A |
The most critical specs to match are: cell count (must be exactly 132), Voc close to 48.88 V (within ±5%), and temperature coefficient TcVoc close to -0.25%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.
A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.
If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original GCL-NT12R/66GDF 635.