570 W TOPCon solar panel with 120 cells. Voc 45.05 V · Isc 16.08 A · TcVoc -0.23%/°C.
Select the panel you want to replace
27 panels found · 4312 panels excluded
575 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 45.05 V | 45.27 V | 0.5% |
| Vmpp | 37.44 V | 37.62 V | 0.5% |
| Isc | 16.08 A | 16.14 A | 0.4% |
| Impp | 15.22 A | 15.28 A | 0.4% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0.000 %/°C |
| TcPmax | -0.28 %/°C | -0.28 %/°C | ±0.000 %/°C |
565 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 45.05 V | 44.83 V | 0.5% |
| Vmpp | 37.44 V | 37.26 V | 0.5% |
| Isc | 16.08 A | 16.01 A | 0.4% |
| Impp | 15.22 A | 15.16 A | 0.4% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0.000 %/°C |
| TcPmax | -0.28 %/°C | -0.28 %/°C | ±0.000 %/°C |
570 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 45.05 V | 45.07 V | 0.0% |
| Vmpp | 37.44 V | 37.61 V | 0.5% |
| Isc | 16.08 A | 16.01 A | 0.4% |
| Impp | 15.22 A | 15.16 A | 0.4% |
| TcVoc | -0.23 %/°C | -0.25 %/°C | ±0.020 %/°C |
| TcPmax | -0.28 %/°C | -0.29 %/°C | ±0.010 %/°C |
580 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 45.05 V | 45.48 V | 1.0% |
| Vmpp | 37.44 V | 37.8 V | 1.0% |
| Isc | 16.08 A | 16.2 A | 0.7% |
| Impp | 15.22 A | 15.34 A | 0.8% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0.000 %/°C |
| TcPmax | -0.28 %/°C | -0.28 %/°C | ±0.000 %/°C |
560 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 45.05 V | 44.62 V | 1.0% |
| Vmpp | 37.44 V | 37.08 V | 1.0% |
| Isc | 16.08 A | 15.95 A | 0.8% |
| Impp | 15.22 A | 15.1 A | 0.8% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0.000 %/°C |
| TcPmax | -0.28 %/°C | -0.28 %/°C | ±0.000 %/°C |
565 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 45.05 V | 44.87 V | 0.4% |
| Vmpp | 37.44 V | 37.41 V | 0.1% |
| Isc | 16.08 A | 15.96 A | 0.7% |
| Impp | 15.22 A | 15.11 A | 0.7% |
| TcVoc | -0.23 %/°C | -0.25 %/°C | ±0.020 %/°C |
| TcPmax | -0.28 %/°C | -0.29 %/°C | ±0.010 %/°C |
575 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 45.05 V | 45.27 V | 0.5% |
| Vmpp | 37.44 V | 37.81 V | 1.0% |
| Isc | 16.08 A | 16.06 A | 0.1% |
| Impp | 15.22 A | 15.21 A | 0.1% |
| TcVoc | -0.23 %/°C | -0.25 %/°C | ±0.020 %/°C |
| TcPmax | -0.28 %/°C | -0.29 %/°C | ±0.010 %/°C |
560 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 45.05 V | 45.01 V | 0.1% |
| Vmpp | 37.44 V | 37.94 V | 1.3% |
| Isc | 16.08 A | 15.7 A | 2.4% |
| Impp | 15.22 A | 14.76 A | 3.0% |
| TcVoc | -0.23 %/°C | -0.25 %/°C | ±0.020 %/°C |
| TcPmax | -0.28 %/°C | -0.29 %/°C | ±0.010 %/°C |
560 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 45.05 V | 45.01 V | 0.1% |
| Vmpp | 37.44 V | 37.94 V | 1.3% |
| Isc | 16.08 A | 15.7 A | 2.4% |
| Impp | 15.22 A | 14.76 A | 3.0% |
| TcVoc | -0.23 %/°C | -0.25 %/°C | ±0.020 %/°C |
| TcPmax | -0.28 %/°C | -0.29 %/°C | ±0.010 %/°C |
560 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 45.05 V | 45.01 V | 0.1% |
| Vmpp | 37.44 V | 37.94 V | 1.3% |
| Isc | 16.08 A | 15.7 A | 2.4% |
| Impp | 15.22 A | 14.76 A | 3.0% |
| TcVoc | -0.23 %/°C | -0.25 %/°C | ±0.020 %/°C |
| TcPmax | -0.28 %/°C | -0.29 %/°C | ±0.010 %/°C |
560 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 45.05 V | 44.67 V | 0.8% |
| Vmpp | 37.44 V | 37.21 V | 0.6% |
| Isc | 16.08 A | 15.91 A | 1.1% |
| Impp | 15.22 A | 15.05 A | 1.1% |
| TcVoc | -0.23 %/°C | -0.25 %/°C | ±0.020 %/°C |
| TcPmax | -0.28 %/°C | -0.29 %/°C | ±0.010 %/°C |
565 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 45.05 V | 45.15 V | 0.2% |
| Vmpp | 37.44 V | 38.18 V | 2.0% |
| Isc | 16.08 A | 15.75 A | 2.1% |
| Impp | 15.22 A | 14.8 A | 2.8% |
| TcVoc | -0.23 %/°C | -0.25 %/°C | ±0.020 %/°C |
| TcPmax | -0.28 %/°C | -0.29 %/°C | ±0.010 %/°C |
String Compatibility Calculator
Verify the replacement panel works with your inverter
Panel Matcher
Find all compatible panels for a specific inverter
Already have panels?
Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.
How the Algorithm Works
Learn how panels are scored and matched
Voc
45.05 V
Vmpp
37.44 V
Isc
16.08 A
Impp
15.22 A
TcVoc
-0.23 %/°C
TcPmax
-0.28 %/°C
Pmax
570 W
Cells
120
Bifaciality
80%
Length
2178 mm
Width
1134 mm
Thickness
30 mm
Weight
30.5 kg
The Horay Solar HS570TC-MHC-D is a 570 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.
Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.
| Model | Power | Voc | Isc |
|---|---|---|---|
| HS560TC-MHC-D | 560 W | 44.62 V | 15.95 A |
| HS565TC-MHC-D | 565 W | 44.83 V | 16.01 A |
| HS575TC-MHC-D | 575 W | 45.27 V | 16.14 A |
| HS580TC-MHC-D | 580 W | 45.48 V | 16.2 A |
The most critical specs to match are: cell count (must be exactly 120), Voc close to 45.05 V (within ±5%), and temperature coefficient TcVoc close to -0.23%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.
A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.
If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original Horay Solar HS570TC-MHC-D.