575 W TOPCon solar panel with 132 cells. Voc 47.76 V · Isc 15.11 A · TcVoc -0.23%/°C.
Select the panel you want to replace
21 panels found · 4318 panels excluded
580 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 47.76 V | 47.98 V | 0.5% |
| Vmpp | 40.52 V | 40.7 V | 0.4% |
| Isc | 15.11 A | 15.18 A | 0.5% |
| Impp | 14.19 A | 14.25 A | 0.4% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0.000 %/°C |
| TcPmax | -0.28 %/°C | -0.28 %/°C | ±0.000 %/°C |
570 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 47.76 V | 47.55 V | 0.4% |
| Vmpp | 40.52 V | 40.33 V | 0.5% |
| Isc | 15.11 A | 15.05 A | 0.4% |
| Impp | 14.19 A | 14.13 A | 0.4% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0.000 %/°C |
| TcPmax | -0.28 %/°C | -0.28 %/°C | ±0.000 %/°C |
555 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 47.76 V | 47.76 V | 0.0% |
| Vmpp | 40.52 V | 40.52 V | 0.0% |
| Isc | 15.11 A | 14.59 A | 3.4% |
| Impp | 14.19 A | 13.7 A | 3.5% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0.000 %/°C |
| TcPmax | -0.28 %/°C | -0.28 %/°C | ±0.000 %/°C |
585 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 47.76 V | 48.05 V | 0.6% |
| Vmpp | 40.52 V | 40.76 V | 0.6% |
| Isc | 15.11 A | 15.29 A | 1.2% |
| Impp | 14.19 A | 14.35 A | 1.1% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0.000 %/°C |
| TcPmax | -0.28 %/°C | -0.28 %/°C | ±0.000 %/°C |
590 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 47.76 V | 48.08 V | 0.7% |
| Vmpp | 40.52 V | 40.79 V | 0.7% |
| Isc | 15.11 A | 15.41 A | 2.0% |
| Impp | 14.19 A | 14.47 A | 2.0% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0.000 %/°C |
| TcPmax | -0.28 %/°C | -0.28 %/°C | ±0.000 %/°C |
560 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 47.76 V | 47.98 V | 0.5% |
| Vmpp | 40.52 V | 40.7 V | 0.4% |
| Isc | 15.11 A | 14.65 A | 3.0% |
| Impp | 14.19 A | 13.76 A | 3.0% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0.000 %/°C |
| TcPmax | -0.28 %/°C | -0.28 %/°C | ±0.000 %/°C |
565 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 47.76 V | 48.05 V | 0.6% |
| Vmpp | 40.52 V | 40.76 V | 0.6% |
| Isc | 15.11 A | 14.76 A | 2.3% |
| Impp | 14.19 A | 13.86 A | 2.3% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0.000 %/°C |
| TcPmax | -0.28 %/°C | -0.28 %/°C | ±0.000 %/°C |
595 W
HPBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 47.76 V | 47.78 V | 0.0% |
| Vmpp | 40.52 V | 39.91 V | 1.5% |
| Isc | 15.11 A | 15.8 A | 4.6% |
| Impp | 14.19 A | 14.91 A | 5.1% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0.000 %/°C |
| TcPmax | -0.28 %/°C | -0.28 %/°C | ±0.000 %/°C |
555 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 47.76 V | 48.27 V | 1.1% |
| Vmpp | 40.52 V | 40.28 V | 0.6% |
| Isc | 15.11 A | 14.56 A | 3.6% |
| Impp | 14.19 A | 13.78 A | 2.9% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0.000 %/°C |
| TcPmax | -0.28 %/°C | -0.28 %/°C | ±0.000 %/°C |
580 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 47.76 V | 48.18 V | 0.9% |
| Vmpp | 40.52 V | 40.42 V | 0.2% |
| Isc | 15.11 A | 15.21 A | 0.7% |
| Impp | 14.19 A | 14.35 A | 1.1% |
| TcVoc | -0.23 %/°C | -0.25 %/°C | ±0.020 %/°C |
| TcPmax | -0.28 %/°C | -0.29 %/°C | ±0.010 %/°C |
560 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 47.76 V | 48.51 V | 1.6% |
| Vmpp | 40.52 V | 40.48 V | 0.1% |
| Isc | 15.11 A | 14.61 A | 3.3% |
| Impp | 14.19 A | 13.83 A | 2.5% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0.000 %/°C |
| TcPmax | -0.28 %/°C | -0.28 %/°C | ±0.000 %/°C |
570 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 47.76 V | 48.41 V | 1.4% |
| Vmpp | 40.52 V | 41.07 V | 1.4% |
| Isc | 15.11 A | 14.78 A | 2.2% |
| Impp | 14.19 A | 13.88 A | 2.2% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0.000 %/°C |
| TcPmax | -0.28 %/°C | -0.28 %/°C | ±0.000 %/°C |
String Compatibility Calculator
Verify the replacement panel works with your inverter
Panel Matcher
Find all compatible panels for a specific inverter
Already have panels?
Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.
How the Algorithm Works
Learn how panels are scored and matched
Voc
47.76 V
Vmpp
40.52 V
Isc
15.11 A
Impp
14.19 A
TcVoc
-0.23 %/°C
TcPmax
-0.28 %/°C
Pmax
575 W
Cells
132
Bifaciality
80%
Length
2279 mm
Width
1134 mm
Thickness
30 mm
Weight
31.5 kg
The Horay Solar HS575TC-MHD-D is a 575 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.
Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.
| Model | Power | Voc | Isc |
|---|---|---|---|
| HS570TC-MHD-D | 570 W | 47.55 V | 15.05 A |
| HS580TC-MHD-D | 580 W | 47.98 V | 15.18 A |
| HS585TC-MHD-D | 585 W | 48.05 V | 15.29 A |
| HS590TC-MHD-D | 590 W | 48.08 V | 15.41 A |
The most critical specs to match are: cell count (must be exactly 132), Voc close to 47.76 V (within ±5%), and temperature coefficient TcVoc close to -0.23%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.
A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.
If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original Horay Solar HS575TC-MHD-D.