605 W TOPCon solar panel with 144 cells. Voc 51.66 V · Isc 14.68 A · TcVoc -0.26%/°C.
Select the panel you want to replace
120 panels found · 4219 panels excluded
600 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.66 V | 51.46 V | 0.4% |
| Vmpp | 42.74 V | 42.54 V | 0.5% |
| Isc | 14.68 A | 14.61 A | 0.5% |
| Impp | 14.16 A | 14.1 A | 0.4% |
| TcVoc | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
| TcPmax | -0.31 %/°C | -0.31 %/°C | ±0.000 %/°C |
610 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.66 V | 51.86 V | 0.4% |
| Vmpp | 42.74 V | 42.94 V | 0.5% |
| Isc | 14.68 A | 14.75 A | 0.5% |
| Impp | 14.16 A | 14.21 A | 0.4% |
| TcVoc | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
| TcPmax | -0.31 %/°C | -0.31 %/°C | ±0.000 %/°C |
585 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.66 V | 51.69 V | 0.1% |
| Vmpp | 42.74 V | 42.77 V | 0.1% |
| Isc | 14.68 A | 14.41 A | 1.8% |
| Impp | 14.16 A | 13.68 A | 3.4% |
| TcVoc | -0.26 %/°C | -0.27 %/°C | ±0.010 %/°C |
| TcPmax | -0.31 %/°C | -0.32 %/°C | ±0.010 %/°C |
590 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.66 V | 51.68 V | 0.0% |
| Vmpp | 42.74 V | 42.91 V | 0.4% |
| Isc | 14.68 A | 14.48 A | 1.4% |
| Impp | 14.16 A | 13.75 A | 2.9% |
| TcVoc | -0.26 %/°C | -0.25 %/°C | ±0.010 %/°C |
| TcPmax | -0.31 %/°C | -0.3 %/°C | ±0.010 %/°C |
615 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.66 V | 52.06 V | 0.8% |
| Vmpp | 42.74 V | 43.14 V | 0.9% |
| Isc | 14.68 A | 14.82 A | 1.0% |
| Impp | 14.16 A | 14.26 A | 0.7% |
| TcVoc | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
| TcPmax | -0.31 %/°C | -0.31 %/°C | ±0.000 %/°C |
585 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.66 V | 51.55 V | 0.2% |
| Vmpp | 42.74 V | 42.79 V | 0.1% |
| Isc | 14.68 A | 14.4 A | 1.9% |
| Impp | 14.16 A | 13.67 A | 3.5% |
| TcVoc | -0.26 %/°C | -0.25 %/°C | ±0.010 %/°C |
| TcPmax | -0.31 %/°C | -0.3 %/°C | ±0.010 %/°C |
595 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.66 V | 51.81 V | 0.3% |
| Vmpp | 42.74 V | 43.02 V | 0.7% |
| Isc | 14.68 A | 14.56 A | 0.8% |
| Impp | 14.16 A | 13.83 A | 2.3% |
| TcVoc | -0.26 %/°C | -0.25 %/°C | ±0.010 %/°C |
| TcPmax | -0.31 %/°C | -0.3 %/°C | ±0.010 %/°C |
590 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.66 V | 51.3 V | 0.7% |
| Vmpp | 42.74 V | 42.67 V | 0.2% |
| Isc | 14.68 A | 14.63 A | 0.3% |
| Impp | 14.16 A | 13.83 A | 2.3% |
| TcVoc | -0.26 %/°C | -0.25 %/°C | ±0.010 %/°C |
| TcPmax | -0.31 %/°C | -0.3 %/°C | ±0.010 %/°C |
590 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.66 V | 51.89 V | 0.4% |
| Vmpp | 42.74 V | 42.92 V | 0.4% |
| Isc | 14.68 A | 14.47 A | 1.4% |
| Impp | 14.16 A | 13.75 A | 2.9% |
| TcVoc | -0.26 %/°C | -0.27 %/°C | ±0.010 %/°C |
| TcPmax | -0.31 %/°C | -0.32 %/°C | ±0.010 %/°C |
600 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.66 V | 51.94 V | 0.5% |
| Vmpp | 42.74 V | 43.13 V | 0.9% |
| Isc | 14.68 A | 14.64 A | 0.3% |
| Impp | 14.16 A | 13.91 A | 1.8% |
| TcVoc | -0.26 %/°C | -0.25 %/°C | ±0.010 %/°C |
| TcPmax | -0.31 %/°C | -0.3 %/°C | ±0.010 %/°C |
590 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.66 V | 51.6 V | 0.1% |
| Vmpp | 42.74 V | 43.4 V | 1.5% |
| Isc | 14.68 A | 14.34 A | 2.3% |
| Impp | 14.16 A | 13.59 A | 4.0% |
| TcVoc | -0.26 %/°C | -0.25 %/°C | ±0.010 %/°C |
| TcPmax | -0.31 %/°C | -0.3 %/°C | ±0.010 %/°C |
620 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.66 V | 52.26 V | 1.2% |
| Vmpp | 42.74 V | 43.34 V | 1.4% |
| Isc | 14.68 A | 14.88 A | 1.4% |
| Impp | 14.16 A | 14.31 A | 1.1% |
| TcVoc | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
| TcPmax | -0.31 %/°C | -0.31 %/°C | ±0.000 %/°C |
String Compatibility Calculator
Verify the replacement panel works with your inverter
Panel Matcher
Find all compatible panels for a specific inverter
Already have panels?
Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.
How the Algorithm Works
Learn how panels are scored and matched
Voc
51.66 V
Vmpp
42.74 V
Isc
14.68 A
Impp
14.16 A
TcVoc
-0.26 %/°C
TcPmax
-0.31 %/°C
Pmax
605 W
Cells
144
Length
2279 mm
Width
1134 mm
Thickness
30 mm
Weight
28 kg
The Inter Energy IE182x182/M/72/605MH is a 605 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.
Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.
| Model | Power | Voc | Isc |
|---|---|---|---|
| IE182x182/M/72/600MH | 600 W | 51.46 V | 14.61 A |
| IE182x182/M/72/610MH | 610 W | 51.86 V | 14.75 A |
| IE182x182/M/72/615MH | 615 W | 52.06 V | 14.82 A |
| IE182x182/M/72/620MH | 620 W | 52.26 V | 14.88 A |
The most critical specs to match are: cell count (must be exactly 144), Voc close to 51.66 V (within ±5%), and temperature coefficient TcVoc close to -0.26%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.
A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.
If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original Inter Energy IE182x182/M/72/605MH.