580 W TOPCon solar panel with 132 cells. Voc 48.18 V · Isc 15.21 A · TcVoc -0.25%/°C.
Select the panel you want to replace
41 panels found · 4298 panels excluded
580 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.18 V | 48.22 V | 0.1% |
| Vmpp | 40.42 V | 40.31 V | 0.3% |
| Isc | 15.21 A | 15.22 A | 0.1% |
| Impp | 14.35 A | 14.39 A | 0.3% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.3 %/°C | ±0.010 %/°C |
585 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.18 V | 48.38 V | 0.4% |
| Vmpp | 40.42 V | 40.63 V | 0.5% |
| Isc | 15.21 A | 15.26 A | 0.3% |
| Impp | 14.35 A | 14.4 A | 0.3% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
585 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.18 V | 48.42 V | 0.5% |
| Vmpp | 40.42 V | 40.51 V | 0.2% |
| Isc | 15.21 A | 15.27 A | 0.4% |
| Impp | 14.35 A | 14.44 A | 0.6% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.3 %/°C | ±0.010 %/°C |
600 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.18 V | 48.28 V | 0.2% |
| Vmpp | 40.42 V | 40.16 V | 0.6% |
| Isc | 15.21 A | 15.84 A | 4.1% |
| Impp | 14.35 A | 14.94 A | 4.1% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
590 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.18 V | 48.58 V | 0.8% |
| Vmpp | 40.42 V | 40.84 V | 1.0% |
| Isc | 15.21 A | 15.31 A | 0.7% |
| Impp | 14.35 A | 14.45 A | 0.7% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
590 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.18 V | 48.62 V | 0.9% |
| Vmpp | 40.42 V | 40.72 V | 0.7% |
| Isc | 15.21 A | 15.32 A | 0.7% |
| Impp | 14.35 A | 14.49 A | 1.0% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.3 %/°C | ±0.010 %/°C |
600 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.18 V | 47.8 V | 0.8% |
| Vmpp | 40.42 V | 40.5 V | 0.2% |
| Isc | 15.21 A | 15.76 A | 3.6% |
| Impp | 14.35 A | 14.81 A | 3.2% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
585 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.18 V | 48.05 V | 0.3% |
| Vmpp | 40.42 V | 40.76 V | 0.8% |
| Isc | 15.21 A | 15.29 A | 0.5% |
| Impp | 14.35 A | 14.35 A | 0.0% |
| TcVoc | -0.25 %/°C | -0.23 %/°C | ±0.020 %/°C |
| TcPmax | -0.29 %/°C | -0.28 %/°C | ±0.010 %/°C |
600 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.18 V | 47.8 V | 0.8% |
| Vmpp | 40.42 V | 40.5 V | 0.2% |
| Isc | 15.21 A | 15.76 A | 3.6% |
| Impp | 14.35 A | 14.81 A | 3.2% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
600 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.18 V | 47.8 V | 0.8% |
| Vmpp | 40.42 V | 40.5 V | 0.2% |
| Isc | 15.21 A | 15.76 A | 3.6% |
| Impp | 14.35 A | 14.81 A | 3.2% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
600 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.18 V | 47.8 V | 0.8% |
| Vmpp | 40.42 V | 40.5 V | 0.2% |
| Isc | 15.21 A | 15.76 A | 3.6% |
| Impp | 14.35 A | 14.81 A | 3.2% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
600 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.18 V | 47.8 V | 0.8% |
| Vmpp | 40.42 V | 40.5 V | 0.2% |
| Isc | 15.21 A | 15.76 A | 3.6% |
| Impp | 14.35 A | 14.81 A | 3.2% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
String Compatibility Calculator
Verify the replacement panel works with your inverter
Panel Matcher
Find all compatible panels for a specific inverter
Already have panels?
Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.
How the Algorithm Works
Learn how panels are scored and matched
Voc
48.18 V
Vmpp
40.42 V
Isc
15.21 A
Impp
14.35 A
TcVoc
-0.25 %/°C
TcPmax
-0.29 %/°C
Pmax
580 W
Cells
132
Bifaciality
80%
Length
2278 mm
Width
1134 mm
Thickness
30 mm
Weight
31.8 kg
The JA Solar JAM66D42-580/MB is a 580 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.
Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.
| Model | Power | Voc | Isc |
|---|---|---|---|
| JAM66D42-585/MB | 585 W | 48.38 V | 15.26 A |
| JAM66D42-590/MB | 590 W | 48.58 V | 15.31 A |
| JAM66D42-595/MB | 595 W | 48.78 V | 15.36 A |
| JAM66D42-600/MB | 600 W | 48.98 V | 15.41 A |
| JAM66D42-605/MB | 605 W | 49.19 V | 15.46 A |
The most critical specs to match are: cell count (must be exactly 132), Voc close to 48.18 V (within ±5%), and temperature coefficient TcVoc close to -0.25%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.
A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.
If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original JA Solar JAM66D42-580/MB.