585 W PERC solar panel with 144 cells. Voc 51.22 V · Isc 14.56 A · TcVoc -0.275%/°C.
Select the panel you want to replace
88 panels found · 4251 panels excluded
580 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.22 V | 51.04 V | 0.4% |
| Vmpp | 42.42 V | 42.24 V | 0.4% |
| Isc | 14.56 A | 14.5 A | 0.4% |
| Impp | 13.79 A | 13.73 A | 0.4% |
| TcVoc | -0.275 %/°C | -0.275 %/°C | ±0.000 %/°C |
| TcPmax | -0.35 %/°C | -0.35 %/°C | ±0.000 %/°C |
575 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.22 V | 50.86 V | 0.7% |
| Vmpp | 42.42 V | 42.05 V | 0.9% |
| Isc | 14.56 A | 14.44 A | 0.8% |
| Impp | 13.79 A | 13.67 A | 0.9% |
| TcVoc | -0.275 %/°C | -0.275 %/°C | ±0.000 %/°C |
| TcPmax | -0.35 %/°C | -0.35 %/°C | ±0.000 %/°C |
580 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.22 V | 51.49 V | 0.5% |
| Vmpp | 42.42 V | 42.62 V | 0.5% |
| Isc | 14.56 A | 14.35 A | 1.4% |
| Impp | 13.79 A | 13.61 A | 1.3% |
| TcVoc | -0.275 %/°C | -0.27 %/°C | ±0.005 %/°C |
| TcPmax | -0.35 %/°C | -0.32 %/°C | ±0.030 %/°C |
570 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.22 V | 50.68 V | 1.1% |
| Vmpp | 42.42 V | 41.87 V | 1.3% |
| Isc | 14.56 A | 14.37 A | 1.3% |
| Impp | 13.79 A | 13.62 A | 1.2% |
| TcVoc | -0.275 %/°C | -0.275 %/°C | ±0.000 %/°C |
| TcPmax | -0.35 %/°C | -0.35 %/°C | ±0.000 %/°C |
600 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.22 V | 51.46 V | 0.5% |
| Vmpp | 42.42 V | 42.54 V | 0.3% |
| Isc | 14.56 A | 14.61 A | 0.3% |
| Impp | 13.79 A | 14.1 A | 2.2% |
| TcVoc | -0.275 %/°C | -0.26 %/°C | ±0.015 %/°C |
| TcPmax | -0.35 %/°C | -0.31 %/°C | ±0.040 %/°C |
585 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.22 V | 51.69 V | 0.9% |
| Vmpp | 42.42 V | 42.77 V | 0.8% |
| Isc | 14.56 A | 14.41 A | 1.0% |
| Impp | 13.79 A | 13.68 A | 0.8% |
| TcVoc | -0.275 %/°C | -0.27 %/°C | ±0.005 %/°C |
| TcPmax | -0.35 %/°C | -0.32 %/°C | ±0.030 %/°C |
585 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.22 V | 51.16 V | 0.1% |
| Vmpp | 42.42 V | 42.52 V | 0.2% |
| Isc | 14.56 A | 14.55 A | 0.1% |
| Impp | 13.79 A | 13.76 A | 0.2% |
| TcVoc | -0.275 %/°C | -0.25 %/°C | ±0.025 %/°C |
| TcPmax | -0.35 %/°C | -0.3 %/°C | ±0.050 %/°C |
565 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.22 V | 50.28 V | 1.8% |
| Vmpp | 42.42 V | 42.42 V | 0.0% |
| Isc | 14.56 A | 14.21 A | 2.4% |
| Impp | 13.79 A | 13.32 A | 3.4% |
| TcVoc | -0.275 %/°C | -0.275 %/°C | ±0.000 %/°C |
| TcPmax | -0.35 %/°C | -0.35 %/°C | ±0.000 %/°C |
590 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.22 V | 51.3 V | 0.2% |
| Vmpp | 42.42 V | 42.67 V | 0.6% |
| Isc | 14.56 A | 14.63 A | 0.5% |
| Impp | 13.79 A | 13.83 A | 0.3% |
| TcVoc | -0.275 %/°C | -0.25 %/°C | ±0.025 %/°C |
| TcPmax | -0.35 %/°C | -0.3 %/°C | ±0.050 %/°C |
565 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.22 V | 50.5 V | 1.4% |
| Vmpp | 42.42 V | 41.68 V | 1.7% |
| Isc | 14.56 A | 14.31 A | 1.7% |
| Impp | 13.79 A | 13.56 A | 1.7% |
| TcVoc | -0.275 %/°C | -0.275 %/°C | ±0.000 %/°C |
| TcPmax | -0.35 %/°C | -0.35 %/°C | ±0.000 %/°C |
580 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.22 V | 51.02 V | 0.4% |
| Vmpp | 42.42 V | 42.37 V | 0.1% |
| Isc | 14.56 A | 14.47 A | 0.6% |
| Impp | 13.79 A | 13.69 A | 0.7% |
| TcVoc | -0.275 %/°C | -0.25 %/°C | ±0.025 %/°C |
| TcPmax | -0.35 %/°C | -0.3 %/°C | ±0.050 %/°C |
590 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.22 V | 51.89 V | 1.3% |
| Vmpp | 42.42 V | 42.92 V | 1.2% |
| Isc | 14.56 A | 14.47 A | 0.6% |
| Impp | 13.79 A | 13.75 A | 0.3% |
| TcVoc | -0.275 %/°C | -0.27 %/°C | ±0.005 %/°C |
| TcPmax | -0.35 %/°C | -0.32 %/°C | ±0.030 %/°C |
String Compatibility Calculator
Verify the replacement panel works with your inverter
Panel Matcher
Find all compatible panels for a specific inverter
Already have panels?
Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.
How the Algorithm Works
Learn how panels are scored and matched
Voc
51.22 V
Vmpp
42.42 V
Isc
14.56 A
Impp
13.79 A
TcVoc
-0.275 %/°C
TcPmax
-0.35 %/°C
Pmax
585 W
Cells
144
Length
2333 mm
Width
1134 mm
Thickness
30 mm
Weight
28 kg
The JA Solar JAM72S30-585/LR is a 585 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.
Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.
| Model | Power | Voc | Isc |
|---|---|---|---|
| JAM72S30-560/LR | 560 W | 50.32 V | 14.25 A |
| JAM72S30-565/LR | 565 W | 50.5 V | 14.31 A |
| JAM72S30-570/LR | 570 W | 50.68 V | 14.37 A |
| JAM72S30-575/LR | 575 W | 50.86 V | 14.44 A |
| JAM72S30-580/LR | 580 W | 51.04 V | 14.5 A |
The most critical specs to match are: cell count (must be exactly 144), Voc close to 51.22 V (within ±5%), and temperature coefficient TcVoc close to -0.275%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.
A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.
If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original JA Solar JAM72S30-585/LR.