445 W TOPCon solar panel with 96 cells. Voc 35.88 V · Isc 15.61 A · TcVoc -0.25%/°C.
Select the panel you want to replace
71 panels found · 4268 panels excluded
450 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 35.88 V | 35.91 V | 0.1% |
| Vmpp | 30.01 V | 30.04 V | 0.1% |
| Isc | 15.61 A | 15.73 A | 0.8% |
| Impp | 14.83 A | 14.98 A | 1.0% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
440 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 35.88 V | 35.81 V | 0.2% |
| Vmpp | 30.01 V | 30.01 V | 0.0% |
| Isc | 15.61 A | 15.62 A | 0.1% |
| Impp | 14.83 A | 14.66 A | 1.1% |
| TcVoc | -0.25 %/°C | -0.24 %/°C | ±0.010 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
440 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 35.88 V | 35.7 V | 0.5% |
| Vmpp | 30.01 V | 29.77 V | 0.8% |
| Isc | 15.61 A | 15.56 A | 0.3% |
| Impp | 14.83 A | 14.78 A | 0.3% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
450 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 35.88 V | 36.06 V | 0.5% |
| Vmpp | 30.01 V | 30.25 V | 0.8% |
| Isc | 15.61 A | 15.66 A | 0.3% |
| Impp | 14.83 A | 14.88 A | 0.3% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
450 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 35.88 V | 35.93 V | 0.1% |
| Vmpp | 30.01 V | 29.68 V | 1.1% |
| Isc | 15.61 A | 16.04 A | 2.8% |
| Impp | 14.83 A | 15.17 A | 2.3% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
445 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 35.88 V | 35.98 V | 0.3% |
| Vmpp | 30.01 V | 30.25 V | 0.8% |
| Isc | 15.61 A | 15.67 A | 0.4% |
| Impp | 14.83 A | 14.71 A | 0.8% |
| TcVoc | -0.25 %/°C | -0.24 %/°C | ±0.010 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
455 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 35.88 V | 35.8 V | 0.2% |
| Vmpp | 30.01 V | 29.9 V | 0.4% |
| Isc | 15.61 A | 16.23 A | 4.0% |
| Impp | 14.83 A | 15.22 A | 2.6% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
455 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 35.88 V | 36.08 V | 0.6% |
| Vmpp | 30.01 V | 30.28 V | 0.9% |
| Isc | 15.61 A | 15.78 A | 1.1% |
| Impp | 14.83 A | 15.03 A | 1.3% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
450 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 35.88 V | 35.75 V | 0.4% |
| Vmpp | 30.01 V | 30.19 V | 0.6% |
| Isc | 15.61 A | 15.95 A | 2.2% |
| Impp | 14.83 A | 14.91 A | 0.5% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.3 %/°C | ±0.010 %/°C |
460 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 35.88 V | 36 V | 0.3% |
| Vmpp | 30.01 V | 30.1 V | 0.3% |
| Isc | 15.61 A | 16.32 A | 4.5% |
| Impp | 14.83 A | 15.28 A | 3.0% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
455 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 35.88 V | 35.95 V | 0.2% |
| Vmpp | 30.01 V | 30.44 V | 1.4% |
| Isc | 15.61 A | 15.98 A | 2.4% |
| Impp | 14.83 A | 14.95 A | 0.8% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.3 %/°C | ±0.010 %/°C |
445 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 35.88 V | 35.76 V | 0.3% |
| Vmpp | 30.01 V | 29.54 V | 1.6% |
| Isc | 15.61 A | 15.94 A | 2.1% |
| Impp | 14.83 A | 15.08 A | 1.7% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
String Compatibility Calculator
Verify the replacement panel works with your inverter
Panel Matcher
Find all compatible panels for a specific inverter
Already have panels?
Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.
How the Algorithm Works
Learn how panels are scored and matched
Voc
35.88 V
Vmpp
30.01 V
Isc
15.61 A
Impp
14.83 A
TcVoc
-0.25 %/°C
TcPmax
-0.29 %/°C
Pmax
445 W
Cells
96
Length
1762 mm
Width
1134 mm
Thickness
30 mm
Weight
21.5 kg
The JinkoSolar JKM445N-48HL4M-DB is a 445 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.
Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.
| Model | Power | Voc | Isc |
|---|---|---|---|
| JKM440N-48HL4M-DB | 440 W | 35.7 V | 15.56 A |
| JKM450N-48HL4M-DB | 450 W | 36.06 V | 15.66 A |
| JKM455N-48HL4M-DB | 455 W | 36.23 V | 15.71 A |
| JKM460N-48HL4M-DB | 460 W | 36.4 V | 15.76 A |
| JKM465N-48HL4M-DB | 465 W | 36.57 V | 15.81 A |
| JKM470N-48HL4M-DB | 470 W | 36.74 V | 15.86 A |
| JKM475N-48HL4M-DB | 475 W | 36.91 V | 15.91 A |
| JKM480N-48HL4M-DB | 480 W | 37.08 V | 15.96 A |
The most critical specs to match are: cell count (must be exactly 96), Voc close to 35.88 V (within ±5%), and temperature coefficient TcVoc close to -0.25%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.
A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.
If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original JinkoSolar JKM445N-48HL4M-DB.