635 W TOPCon solar panel with 132 cells. Voc 49.68 V · Isc 16.26 A · TcVoc -0.25%/°C.
Select the panel you want to replace
193 panels found · 4146 panels excluded
635 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.68 V | 49.68 V | 0.0% |
| Vmpp | 41.16 V | 41.16 V | 0.0% |
| Isc | 16.26 A | 16.26 A | 0.0% |
| Impp | 15.43 A | 15.43 A | 0.0% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
635 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.68 V | 49.68 V | 0.0% |
| Vmpp | 41.16 V | 41.16 V | 0.0% |
| Isc | 16.26 A | 16.26 A | 0.0% |
| Impp | 15.43 A | 15.43 A | 0.0% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
635 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.68 V | 49.7 V | 0.0% |
| Vmpp | 41.16 V | 41.31 V | 0.4% |
| Isc | 16.26 A | 16.25 A | 0.1% |
| Impp | 15.43 A | 15.37 A | 0.4% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
635 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.68 V | 49.69 V | 0.0% |
| Vmpp | 41.16 V | 41.45 V | 0.7% |
| Isc | 16.26 A | 16.29 A | 0.2% |
| Impp | 15.43 A | 15.35 A | 0.5% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
635 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.68 V | 49.65 V | 0.1% |
| Vmpp | 41.16 V | 41.35 V | 0.5% |
| Isc | 16.26 A | 16.22 A | 0.2% |
| Impp | 15.43 A | 15.37 A | 0.4% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
635 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.68 V | 49.69 V | 0.0% |
| Vmpp | 41.16 V | 41.45 V | 0.7% |
| Isc | 16.26 A | 16.29 A | 0.2% |
| Impp | 15.43 A | 15.35 A | 0.5% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
640 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.68 V | 49.65 V | 0.1% |
| Vmpp | 41.16 V | 41.01 V | 0.4% |
| Isc | 16.26 A | 16.5 A | 1.5% |
| Impp | 15.43 A | 15.61 A | 1.2% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
630 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.68 V | 49.5 V | 0.4% |
| Vmpp | 41.16 V | 41.15 V | 0.0% |
| Isc | 16.26 A | 16.19 A | 0.4% |
| Impp | 15.43 A | 15.31 A | 0.8% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
640 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.68 V | 49.62 V | 0.1% |
| Vmpp | 41.16 V | 40.99 V | 0.4% |
| Isc | 16.26 A | 16.51 A | 1.5% |
| Impp | 15.43 A | 15.62 A | 1.2% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
630 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.68 V | 49.46 V | 0.4% |
| Vmpp | 41.16 V | 41.17 V | 0.0% |
| Isc | 16.26 A | 16.16 A | 0.6% |
| Impp | 15.43 A | 15.31 A | 0.8% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
630 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.68 V | 49.49 V | 0.4% |
| Vmpp | 41.16 V | 41.25 V | 0.2% |
| Isc | 16.26 A | 16.23 A | 0.2% |
| Impp | 15.43 A | 15.3 A | 0.8% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
630 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.68 V | 49.49 V | 0.4% |
| Vmpp | 41.16 V | 41.25 V | 0.2% |
| Isc | 16.26 A | 16.23 A | 0.2% |
| Impp | 15.43 A | 15.3 A | 0.8% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
String Compatibility Calculator
Verify the replacement panel works with your inverter
Panel Matcher
Find all compatible panels for a specific inverter
Already have panels?
Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.
How the Algorithm Works
Learn how panels are scored and matched
Voc
49.68 V
Vmpp
41.16 V
Isc
16.26 A
Impp
15.43 A
TcVoc
-0.25 %/°C
TcPmax
-0.29 %/°C
Pmax
635 W
Cells
132
Bifaciality
80%
Length
2382 mm
Width
1134 mm
Thickness
30 mm
Weight
32.4 kg
The JinkoSolar JKM635N-66HL4M-BDV is a 635 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.
Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.
| Model | Power | Voc | Isc |
|---|---|---|---|
| JKM630N-66HL4M-BDV | 630 W | 49.48 V | 16.2 A |
| JKM640N-66HL4M-BDV | 640 W | 49.88 V | 16.32 A |
| JKM645N-66HL4M-BDV | 645 W | 50.08 V | 16.38 A |
| JKM650N-66HL4M-BDV | 650 W | 50.28 V | 16.44 A |
| JKM655N-66HL4M-BDV | 655 W | 50.47 V | 16.5 A |
The most critical specs to match are: cell count (must be exactly 132), Voc close to 49.68 V (within ±5%), and temperature coefficient TcVoc close to -0.25%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.
A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.
If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original JinkoSolar JKM635N-66HL4M-BDV.