595 W TOPCon solar panel with 132 cells. Voc 48.82 V · Isc 15.34 A · TcVoc -0.25%/°C.
Select the panel you want to replace
99 panels found · 4240 panels excluded
595 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.82 V | 48.78 V | 0.1% |
| Vmpp | 40.92 V | 41.03 V | 0.3% |
| Isc | 15.34 A | 15.36 A | 0.1% |
| Impp | 14.54 A | 14.5 A | 0.3% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.3 %/°C | -0.29 %/°C | ±0.010 %/°C |
590 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.82 V | 48.62 V | 0.4% |
| Vmpp | 40.92 V | 40.72 V | 0.5% |
| Isc | 15.34 A | 15.32 A | 0.1% |
| Impp | 14.54 A | 14.49 A | 0.3% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.3 %/°C | -0.3 %/°C | ±0.000 %/°C |
600 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.82 V | 49.02 V | 0.4% |
| Vmpp | 40.92 V | 41.12 V | 0.5% |
| Isc | 15.34 A | 15.4 A | 0.4% |
| Impp | 14.54 A | 14.59 A | 0.3% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.3 %/°C | -0.3 %/°C | ±0.000 %/°C |
590 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.82 V | 48.58 V | 0.5% |
| Vmpp | 40.92 V | 40.84 V | 0.2% |
| Isc | 15.34 A | 15.31 A | 0.2% |
| Impp | 14.54 A | 14.45 A | 0.6% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.3 %/°C | -0.29 %/°C | ±0.010 %/°C |
600 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.82 V | 48.98 V | 0.3% |
| Vmpp | 40.92 V | 41.24 V | 0.8% |
| Isc | 15.34 A | 15.41 A | 0.5% |
| Impp | 14.54 A | 14.55 A | 0.1% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.3 %/°C | -0.29 %/°C | ±0.010 %/°C |
610 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.82 V | 48.95 V | 0.3% |
| Vmpp | 40.92 V | 41.11 V | 0.5% |
| Isc | 15.34 A | 15.48 A | 0.9% |
| Impp | 14.54 A | 14.84 A | 2.1% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.3 %/°C | -0.29 %/°C | ±0.010 %/°C |
585 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.82 V | 48.42 V | 0.8% |
| Vmpp | 40.92 V | 40.51 V | 1.0% |
| Isc | 15.34 A | 15.27 A | 0.5% |
| Impp | 14.54 A | 14.44 A | 0.7% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.3 %/°C | -0.3 %/°C | ±0.000 %/°C |
610 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.82 V | 48.68 V | 0.3% |
| Vmpp | 40.92 V | 41.38 V | 1.1% |
| Isc | 15.34 A | 15.66 A | 2.1% |
| Impp | 14.54 A | 14.74 A | 1.4% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.3 %/°C | -0.29 %/°C | ±0.010 %/°C |
610 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.82 V | 48.92 V | 0.2% |
| Vmpp | 40.92 V | 40.71 V | 0.5% |
| Isc | 15.34 A | 15.87 A | 3.5% |
| Impp | 14.54 A | 14.99 A | 3.1% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.3 %/°C | -0.29 %/°C | ±0.010 %/°C |
615 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.82 V | 48.73 V | 0.2% |
| Vmpp | 40.92 V | 41.42 V | 1.2% |
| Isc | 15.34 A | 15.78 A | 2.9% |
| Impp | 14.54 A | 14.85 A | 2.1% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.3 %/°C | -0.29 %/°C | ±0.010 %/°C |
610 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.82 V | 48.74 V | 0.2% |
| Vmpp | 40.92 V | 41.31 V | 1.0% |
| Isc | 15.34 A | 15.94 A | 3.9% |
| Impp | 14.54 A | 14.77 A | 1.6% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.3 %/°C | -0.29 %/°C | ±0.010 %/°C |
610 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.82 V | 49.05 V | 0.5% |
| Vmpp | 40.92 V | 40.66 V | 0.6% |
| Isc | 15.34 A | 15.84 A | 3.3% |
| Impp | 14.54 A | 15 A | 3.2% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.3 %/°C | -0.3 %/°C | ±0.000 %/°C |
String Compatibility Calculator
Verify the replacement panel works with your inverter
Panel Matcher
Find all compatible panels for a specific inverter
Already have panels?
Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.
How the Algorithm Works
Learn how panels are scored and matched
Voc
48.82 V
Vmpp
40.92 V
Isc
15.34 A
Impp
14.54 A
TcVoc
-0.25 %/°C
TcPmax
-0.3 %/°C
Pmax
595 W
Cells
132
Bifaciality
80%
Length
2279 mm
Width
1134 mm
Thickness
30 mm
Weight
32 kg
The Leapton Energy LP182*199-M-66-NB-595W is a 595 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.
Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.
| Model | Power | Voc | Isc |
|---|---|---|---|
| LP182*199-M-66-NB-580W | 580 W | 48.22 V | 15.22 A |
| LP182*199-M-66-NB-585W | 585 W | 48.42 V | 15.27 A |
| LP182*199-M-66-NB-590W | 590 W | 48.62 V | 15.32 A |
| LP182*199-M-66-NB-600W | 600 W | 49.02 V | 15.4 A |
The most critical specs to match are: cell count (must be exactly 132), Voc close to 48.82 V (within ±5%), and temperature coefficient TcVoc close to -0.25%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.
A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.
If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original Leapton Energy LP182*199-M-66-NB-595W.