405 W PERC solar panel with 108 cells. Voc 37 V · Isc 13.83 A · TcVoc -0.265%/°C.
Select the panel you want to replace
59 panels found · 3452 panels excluded
405 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 37 V | 37 V | 0.0% |
| Vmpp | 31 V | 31 V | 0.0% |
| Isc | 13.83 A | 13.83 A | 0.0% |
| Impp | 13.07 A | 13.07 A | 0.0% |
| TcVoc | -0.265 %/°C | -0.265 %/°C | ±0.000 %/°C |
| TcPmax | -0.34 %/°C | -0.34 %/°C | ±0.000 %/°C |
405 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 37 V | 37.11 V | 0.3% |
| Vmpp | 31 V | 31.15 V | 0.5% |
| Isc | 13.83 A | 13.7 A | 0.9% |
| Impp | 13.07 A | 13.01 A | 0.5% |
| TcVoc | -0.265 %/°C | -0.27 %/°C | ±0.005 %/°C |
| TcPmax | -0.34 %/°C | -0.34 %/°C | ±0.000 %/°C |
410 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 37 V | 37.25 V | 0.7% |
| Vmpp | 31 V | 31.25 V | 0.8% |
| Isc | 13.83 A | 13.88 A | 0.4% |
| Impp | 13.07 A | 13.12 A | 0.4% |
| TcVoc | -0.265 %/°C | -0.265 %/°C | ±0.000 %/°C |
| TcPmax | -0.34 %/°C | -0.34 %/°C | ±0.000 %/°C |
400 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 37 V | 36.75 V | 0.7% |
| Vmpp | 31 V | 30.75 V | 0.8% |
| Isc | 13.83 A | 13.76 A | 0.5% |
| Impp | 13.07 A | 13.01 A | 0.5% |
| TcVoc | -0.265 %/°C | -0.265 %/°C | ±0.000 %/°C |
| TcPmax | -0.34 %/°C | -0.34 %/°C | ±0.000 %/°C |
410 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 37 V | 37.25 V | 0.7% |
| Vmpp | 31 V | 31.25 V | 0.8% |
| Isc | 13.83 A | 13.88 A | 0.4% |
| Impp | 13.07 A | 13.12 A | 0.4% |
| TcVoc | -0.265 %/°C | -0.265 %/°C | ±0.000 %/°C |
| TcPmax | -0.34 %/°C | -0.34 %/°C | ±0.000 %/°C |
400 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 37 V | 37.06 V | 0.2% |
| Vmpp | 31 V | 30.65 V | 1.1% |
| Isc | 13.83 A | 13.78 A | 0.4% |
| Impp | 13.07 A | 13.06 A | 0.1% |
| TcVoc | -0.265 %/°C | -0.27 %/°C | ±0.005 %/°C |
| TcPmax | -0.34 %/°C | -0.35 %/°C | ±0.010 %/°C |
405 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 37 V | 37.17 V | 0.5% |
| Vmpp | 31 V | 30.8 V | 0.6% |
| Isc | 13.83 A | 13.86 A | 0.2% |
| Impp | 13.07 A | 13.15 A | 0.6% |
| TcVoc | -0.265 %/°C | -0.27 %/°C | ±0.005 %/°C |
| TcPmax | -0.34 %/°C | -0.35 %/°C | ±0.010 %/°C |
395 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 37 V | 36.95 V | 0.1% |
| Vmpp | 31 V | 30.5 V | 1.6% |
| Isc | 13.83 A | 13.7 A | 0.9% |
| Impp | 13.07 A | 12.96 A | 0.8% |
| TcVoc | -0.265 %/°C | -0.27 %/°C | ±0.005 %/°C |
| TcPmax | -0.34 %/°C | -0.35 %/°C | ±0.010 %/°C |
410 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 37 V | 37.26 V | 0.7% |
| Vmpp | 31 V | 31.3 V | 1.0% |
| Isc | 13.83 A | 13.79 A | 0.3% |
| Impp | 13.07 A | 13.1 A | 0.2% |
| TcVoc | -0.265 %/°C | -0.27 %/°C | ±0.005 %/°C |
| TcPmax | -0.34 %/°C | -0.34 %/°C | ±0.000 %/°C |
410 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 37 V | 37.28 V | 0.8% |
| Vmpp | 31 V | 30.95 V | 0.2% |
| Isc | 13.83 A | 13.94 A | 0.8% |
| Impp | 13.07 A | 13.25 A | 1.4% |
| TcVoc | -0.265 %/°C | -0.27 %/°C | ±0.005 %/°C |
| TcPmax | -0.34 %/°C | -0.35 %/°C | ±0.010 %/°C |
405 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 37 V | 36.93 V | 0.2% |
| Vmpp | 31 V | 31.16 V | 0.5% |
| Isc | 13.83 A | 13.61 A | 1.6% |
| Impp | 13.07 A | 13 A | 0.5% |
| TcVoc | -0.265 %/°C | -0.28 %/°C | ±0.015 %/°C |
| TcPmax | -0.34 %/°C | -0.35 %/°C | ±0.010 %/°C |
410 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 37 V | 37.08 V | 0.2% |
| Vmpp | 31 V | 31.31 V | 1.0% |
| Isc | 13.83 A | 13.7 A | 0.9% |
| Impp | 13.07 A | 13.09 A | 0.2% |
| TcVoc | -0.265 %/°C | -0.28 %/°C | ±0.015 %/°C |
| TcPmax | -0.34 %/°C | -0.35 %/°C | ±0.010 %/°C |
String Compatibility Calculator
Verify the replacement panel works with your inverter
Panel Matcher
Find all compatible panels for a specific inverter
Already have panels?
Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.
How the Algorithm Works
Learn how panels are scored and matched
Voc
37 V
Vmpp
31 V
Isc
13.83 A
Impp
13.07 A
TcVoc
-0.265 %/°C
TcPmax
-0.34 %/°C
Pmax
405 W
Cells
108
Length
1722 mm
Width
1134 mm
Thickness
30 mm
Weight
20.8 kg
The LONGi LR5-54HIH-405M is a 405 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.
Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.
| Model | Power | Voc | Isc |
|---|---|---|---|
| 400 W | 36.75 V | 13.76 A | |
| 410 W | 37.25 V | 13.88 A | |
| 415 W | 37.5 V | 13.94 A | |
| 420 W | 37.75 V | 14.01 A |
The most critical specs to match are: cell count (must be exactly 108), Voc close to 37 V (within ±5%), and temperature coefficient TcVoc close to -0.265%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.
A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.
If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original LONGi LR5-54HIH-405M.