415 W PERC solar panel with 108 cells. Voc 37.5 V · Isc 13.94 A · TcVoc -0.265%/°C.
Select the panel you want to replace
76 panels found · 3435 panels excluded
415 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 37.5 V | 37.5 V | 0.0% |
| Vmpp | 31.49 V | 31.49 V | 0.0% |
| Isc | 13.94 A | 13.94 A | 0.0% |
| Impp | 13.18 A | 13.18 A | 0.0% |
| TcVoc | -0.265 %/°C | -0.265 %/°C | ±0.000 %/°C |
| TcPmax | -0.34 %/°C | -0.34 %/°C | ±0.000 %/°C |
415 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 37.5 V | 37.41 V | 0.2% |
| Vmpp | 31.49 V | 31.45 V | 0.1% |
| Isc | 13.94 A | 13.89 A | 0.4% |
| Impp | 13.18 A | 13.2 A | 0.2% |
| TcVoc | -0.265 %/°C | -0.27 %/°C | ±0.005 %/°C |
| TcPmax | -0.34 %/°C | -0.34 %/°C | ±0.000 %/°C |
420 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 37.5 V | 37.56 V | 0.2% |
| Vmpp | 31.49 V | 31.6 V | 0.3% |
| Isc | 13.94 A | 13.98 A | 0.3% |
| Impp | 13.18 A | 13.3 A | 0.9% |
| TcVoc | -0.265 %/°C | -0.27 %/°C | ±0.005 %/°C |
| TcPmax | -0.34 %/°C | -0.34 %/°C | ±0.000 %/°C |
410 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 37.5 V | 37.25 V | 0.7% |
| Vmpp | 31.49 V | 31.25 V | 0.8% |
| Isc | 13.94 A | 13.88 A | 0.4% |
| Impp | 13.18 A | 13.12 A | 0.5% |
| TcVoc | -0.265 %/°C | -0.265 %/°C | ±0.000 %/°C |
| TcPmax | -0.34 %/°C | -0.34 %/°C | ±0.000 %/°C |
420 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 37.5 V | 37.75 V | 0.7% |
| Vmpp | 31.49 V | 31.73 V | 0.8% |
| Isc | 13.94 A | 14.01 A | 0.5% |
| Impp | 13.18 A | 13.24 A | 0.5% |
| TcVoc | -0.265 %/°C | -0.265 %/°C | ±0.000 %/°C |
| TcPmax | -0.34 %/°C | -0.34 %/°C | ±0.000 %/°C |
410 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 37.5 V | 37.25 V | 0.7% |
| Vmpp | 31.49 V | 31.25 V | 0.8% |
| Isc | 13.94 A | 13.88 A | 0.4% |
| Impp | 13.18 A | 13.12 A | 0.5% |
| TcVoc | -0.265 %/°C | -0.265 %/°C | ±0.000 %/°C |
| TcPmax | -0.34 %/°C | -0.34 %/°C | ±0.000 %/°C |
420 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 37.5 V | 37.75 V | 0.7% |
| Vmpp | 31.49 V | 31.73 V | 0.8% |
| Isc | 13.94 A | 14.01 A | 0.5% |
| Impp | 13.18 A | 13.24 A | 0.5% |
| TcVoc | -0.265 %/°C | -0.265 %/°C | ±0.000 %/°C |
| TcPmax | -0.34 %/°C | -0.34 %/°C | ±0.000 %/°C |
410 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 37.5 V | 37.26 V | 0.6% |
| Vmpp | 31.49 V | 31.3 V | 0.6% |
| Isc | 13.94 A | 13.79 A | 1.1% |
| Impp | 13.18 A | 13.1 A | 0.6% |
| TcVoc | -0.265 %/°C | -0.27 %/°C | ±0.005 %/°C |
| TcPmax | -0.34 %/°C | -0.34 %/°C | ±0.000 %/°C |
415 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 37.5 V | 37.39 V | 0.3% |
| Vmpp | 31.49 V | 31.1 V | 1.2% |
| Isc | 13.94 A | 14.02 A | 0.6% |
| Impp | 13.18 A | 13.35 A | 1.3% |
| TcVoc | -0.265 %/°C | -0.27 %/°C | ±0.005 %/°C |
| TcPmax | -0.34 %/°C | -0.35 %/°C | ±0.010 %/°C |
420 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 37.5 V | 37.38 V | 0.3% |
| Vmpp | 31.49 V | 31.61 V | 0.4% |
| Isc | 13.94 A | 13.89 A | 0.4% |
| Impp | 13.18 A | 13.29 A | 0.8% |
| TcVoc | -0.265 %/°C | -0.28 %/°C | ±0.015 %/°C |
| TcPmax | -0.34 %/°C | -0.35 %/°C | ±0.010 %/°C |
410 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 37.5 V | 37.51 V | 0.0% |
| Vmpp | 31.49 V | 31.51 V | 0.1% |
| Isc | 13.94 A | 13.75 A | 1.4% |
| Impp | 13.18 A | 13.02 A | 1.2% |
| TcVoc | -0.265 %/°C | -0.285 %/°C | ±0.020 %/°C |
| TcPmax | -0.34 %/°C | -0.36 %/°C | ±0.020 %/°C |
410 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 37.5 V | 37.45 V | 0.1% |
| Vmpp | 31.49 V | 31.59 V | 0.3% |
| Isc | 13.94 A | 13.88 A | 0.4% |
| Impp | 13.18 A | 12.98 A | 1.5% |
| TcVoc | -0.265 %/°C | -0.304 %/°C | ±0.039 %/°C |
| TcPmax | -0.34 %/°C | -0.34 %/°C | ±0.000 %/°C |
String Compatibility Calculator
Verify the replacement panel works with your inverter
Panel Matcher
Find all compatible panels for a specific inverter
Already have panels?
Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.
How the Algorithm Works
Learn how panels are scored and matched
Voc
37.5 V
Vmpp
31.49 V
Isc
13.94 A
Impp
13.18 A
TcVoc
-0.265 %/°C
TcPmax
-0.34 %/°C
Pmax
415 W
Cells
108
Length
1722 mm
Width
1134 mm
Thickness
30 mm
Weight
20.8 kg
The LONGi LR5-54HIH-415M is a 415 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.
Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.
| Model | Power | Voc | Isc |
|---|---|---|---|
| 400 W | 36.75 V | 13.76 A | |
| 405 W | 37 V | 13.83 A | |
| 410 W | 37.25 V | 13.88 A | |
| 420 W | 37.75 V | 14.01 A |
The most critical specs to match are: cell count (must be exactly 108), Voc close to 37.5 V (within ±5%), and temperature coefficient TcVoc close to -0.265%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.
A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.
If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original LONGi LR5-54HIH-415M.