Find replacement for LONGi LR5-54HPH-425M

425 W PERC solar panel with 108 cells. Voc 37.9 V · Isc 14.08 A · TcVoc -0.265%/°C.

Select the panel you want to replace

Show only panels with matching cell technology

Compatible Replacements

128 panels found · 4211 panels excluded

Sunway SW425M-108

425 W

PERC
95Exact match
ParameterOriginalReplacementDeviation
Voc37.9 V37.96 V0.2%
Vmpp31.94 V31.9 V0.1%
Isc14.08 A14.08 A0.0%
Impp13.31 A13.33 A0.2%
TcVoc-0.265 %/°C-0.27 %/°C±0.005 %/°C
TcPmax-0.34 %/°C-0.34 %/°C±0.000 %/°C
Perlight Solar PLM-425H8MB-108

425 W

PERC
94Good match
ParameterOriginalReplacementDeviation
Voc37.9 V37.83 V0.2%
Vmpp31.94 V32 V0.2%
Isc14.08 A14.11 A0.2%
Impp13.31 A13.28 A0.2%
TcVoc-0.265 %/°C-0.27 %/°C±0.005 %/°C
TcPmax-0.34 %/°C-0.34 %/°C±0.000 %/°C
LONGi LR5-54HPH-420M

420 W

PERC
91Good match
ParameterOriginalReplacementDeviation
Voc37.9 V37.75 V0.4%
Vmpp31.94 V31.73 V0.7%
Isc14.08 A14.01 A0.5%
Impp13.31 A13.24 A0.5%
TcVoc-0.265 %/°C-0.265 %/°C±0.000 %/°C
TcPmax-0.34 %/°C-0.34 %/°C±0.000 %/°C
LONGi LR5-54HIH-420M

420 W

PERC
91Good match
ParameterOriginalReplacementDeviation
Voc37.9 V37.75 V0.4%
Vmpp31.94 V31.73 V0.7%
Isc14.08 A14.01 A0.5%
Impp13.31 A13.24 A0.5%
TcVoc-0.265 %/°C-0.265 %/°C±0.000 %/°C
TcPmax-0.34 %/°C-0.34 %/°C±0.000 %/°C
Perlight Solar PLM-430H8MB-108

430 W

PERC
90Good match
ParameterOriginalReplacementDeviation
Voc37.9 V37.98 V0.2%
Vmpp31.94 V32.2 V0.8%
Isc14.08 A14.17 A0.6%
Impp13.31 A13.36 A0.4%
TcVoc-0.265 %/°C-0.27 %/°C±0.005 %/°C
TcPmax-0.34 %/°C-0.34 %/°C±0.000 %/°C
TommaTech TT420-108TNFB10 Dark Series

420 W

TOPCon
85Good match
ParameterOriginalReplacementDeviation
Voc37.9 V37.91 V0.0%
Vmpp31.94 V31.94 V0.0%
Isc14.08 A13.95 A0.9%
Impp13.31 A13.15 A1.2%
TcVoc-0.265 %/°C-0.26 %/°C±0.005 %/°C
TcPmax-0.34 %/°C-0.3 %/°C±0.040 %/°C
Perlight Solar PLM-420H8NB-108

420 W

TOPCon
82Good match
ParameterOriginalReplacementDeviation
Voc37.9 V38.02 V0.3%
Vmpp31.94 V31.63 V1.0%
Isc14.08 A14.05 A0.2%
Impp13.31 A13.28 A0.2%
TcVoc-0.265 %/°C-0.26 %/°C±0.005 %/°C
TcPmax-0.34 %/°C-0.31 %/°C±0.030 %/°C
Jolywood JW-HT108N-420

420 W

TOPCon
80Good match
ParameterOriginalReplacementDeviation
Voc37.9 V37.9 V0.0%
Vmpp31.94 V31.9 V0.1%
Isc14.08 A13.98 A0.7%
Impp13.31 A13.17 A1.1%
TcVoc-0.265 %/°C-0.25 %/°C±0.015 %/°C
TcPmax-0.34 %/°C-0.3 %/°C±0.040 %/°C
Sunway SW420M-108

420 W

PERC
80Good match
ParameterOriginalReplacementDeviation
Voc37.9 V37.56 V0.9%
Vmpp31.94 V31.6 V1.1%
Isc14.08 A13.98 A0.7%
Impp13.31 A13.3 A0.1%
TcVoc-0.265 %/°C-0.27 %/°C±0.005 %/°C
TcPmax-0.34 %/°C-0.34 %/°C±0.000 %/°C
Perlight Solar PLM-415H8NB-108

415 W

TOPCon
79Acceptable
ParameterOriginalReplacementDeviation
Voc37.9 V37.83 V0.2%
Vmpp31.94 V31.44 V1.6%
Isc14.08 A13.97 A0.8%
Impp13.31 A13.2 A0.8%
TcVoc-0.265 %/°C-0.26 %/°C±0.005 %/°C
TcPmax-0.34 %/°C-0.31 %/°C±0.030 %/°C
LONGi LR5-54HPH-415M

415 W

PERC
78Acceptable
ParameterOriginalReplacementDeviation
Voc37.9 V37.5 V1.1%
Vmpp31.94 V31.49 V1.4%
Isc14.08 A13.94 A1.0%
Impp13.31 A13.18 A1.0%
TcVoc-0.265 %/°C-0.265 %/°C±0.000 %/°C
TcPmax-0.34 %/°C-0.34 %/°C±0.000 %/°C
LONGi LR5-54HIH-415M

415 W

PERC
78Acceptable
ParameterOriginalReplacementDeviation
Voc37.9 V37.5 V1.1%
Vmpp31.94 V31.49 V1.4%
Isc14.08 A13.94 A1.0%
Impp13.31 A13.18 A1.0%
TcVoc-0.265 %/°C-0.265 %/°C±0.000 %/°C
TcPmax-0.34 %/°C-0.34 %/°C±0.000 %/°C

String Compatibility Calculator

Verify the replacement panel works with your inverter

Panel Matcher

Find all compatible panels for a specific inverter

Already have panels?

Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.

How the Algorithm Works

Learn how panels are scored and matched

Original Panel Specs

Voc

37.9 V

Vmpp

31.94 V

Isc

14.08 A

Impp

13.31 A

TcVoc

-0.265 %/°C

TcPmax

-0.34 %/°C

Pmax

425 W

Cells

108

Length

1722 mm

Width

1134 mm

Thickness

30 mm

Weight

20.8 kg

The LONGi LR5-54HPH-425M is a 425 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.

Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.

Other models in this series

ModelPowerVocIsc
LR5-54HPH-405M405 W37 V13.83 A
LR5-54HPH-410M410 W37.25 V13.88 A
LR5-54HPH-415M415 W37.5 V13.94 A
LR5-54HPH-420M420 W37.75 V14.01 A

Frequently Asked Questions

What specs must match when replacing the LONGi LR5-54HPH-425M?

The most critical specs to match are: cell count (must be exactly 108), Voc close to 37.9 V (within ±5%), and temperature coefficient TcVoc close to -0.265%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.

Can I use a higher wattage replacement for the LONGi LR5-54HPH-425M?

A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.

What happens if the replacement panel has different voltage specs?

If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original LONGi LR5-54HPH-425M.