Find replacement for LONGi LR5-54HTH-430M

430 W HPBC solar panel with 108 cells. Voc 39.13 V · Isc 14.15 A · TcVoc -0.23%/°C.

Select the panel you want to replace

Show only panels with matching cell technology

Compatible Replacements

162 panels found · 4177 panels excluded

Maysun Solar MS430BC-54H

430 W

IBC
100Exact match
ParameterOriginalReplacementDeviation
Voc39.13 V39.13 V0.0%
Vmpp32.84 V32.84 V0.0%
Isc14.15 A14.15 A0.0%
Impp13.1 A13.1 A0.0%
TcVoc-0.23 %/°C-0.23 %/°C±0.000 %/°C
TcPmax-0.29 %/°C-0.29 %/°C±0.000 %/°C
Horay Solar HS430TC-MHO

430 W

TOPCon
92Good match
ParameterOriginalReplacementDeviation
Voc39.13 V39.3 V0.4%
Vmpp32.84 V32.84 V0.0%
Isc14.15 A14.15 A0.0%
Impp13.1 A13.1 A0.0%
TcVoc-0.23 %/°C-0.23 %/°C±0.000 %/°C
TcPmax-0.29 %/°C-0.28 %/°C±0.010 %/°C
Maysun Solar MS425BC-54HB

425 W

IBC
91Good match
ParameterOriginalReplacementDeviation
Voc39.13 V39.23 V0.3%
Vmpp32.84 V32.96 V0.4%
Isc14.15 A13.94 A1.5%
Impp13.1 A12.91 A1.5%
TcVoc-0.23 %/°C-0.23 %/°C±0.000 %/°C
TcPmax-0.29 %/°C-0.29 %/°C±0.000 %/°C
LONGi LR5-54HTB-425M

425 W

HPBC
91Good match
ParameterOriginalReplacementDeviation
Voc39.13 V39.23 V0.3%
Vmpp32.84 V32.96 V0.4%
Isc14.15 A13.93 A1.6%
Impp13.1 A12.9 A1.5%
TcVoc-0.23 %/°C-0.23 %/°C±0.000 %/°C
TcPmax-0.29 %/°C-0.29 %/°C±0.000 %/°C
Perlight Solar PLM-435H8NB-108 BW BC

435 W

HPBC
90Good match
ParameterOriginalReplacementDeviation
Voc39.13 V39.33 V0.5%
Vmpp32.84 V33.04 V0.6%
Isc14.15 A14.22 A0.5%
Impp13.1 A13.17 A0.5%
TcVoc-0.23 %/°C-0.23 %/°C±0.000 %/°C
TcPmax-0.29 %/°C-0.29 %/°C±0.000 %/°C
LONGi LR5-54HTB-420M

420 W

HPBC
90Good match
ParameterOriginalReplacementDeviation
Voc39.13 V39.03 V0.3%
Vmpp32.84 V32.76 V0.2%
Isc14.15 A13.85 A2.1%
Impp13.1 A12.83 A2.1%
TcVoc-0.23 %/°C-0.23 %/°C±0.000 %/°C
TcPmax-0.29 %/°C-0.29 %/°C±0.000 %/°C
LONGi LR5-54HTH-435M

435 W

HPBC
90Good match
ParameterOriginalReplacementDeviation
Voc39.13 V39.33 V0.5%
Vmpp32.84 V33.04 V0.6%
Isc14.15 A14.22 A0.5%
Impp13.1 A13.17 A0.5%
TcVoc-0.23 %/°C-0.23 %/°C±0.000 %/°C
TcPmax-0.29 %/°C-0.29 %/°C±0.000 %/°C
Maysun Solar MS435BC-54H

435 W

IBC
90Good match
ParameterOriginalReplacementDeviation
Voc39.13 V39.33 V0.5%
Vmpp32.84 V33.04 V0.6%
Isc14.15 A14.22 A0.5%
Impp13.1 A13.17 A0.5%
TcVoc-0.23 %/°C-0.23 %/°C±0.000 %/°C
TcPmax-0.29 %/°C-0.29 %/°C±0.000 %/°C
LONGi LR7-54HGBB-440M

440 W

HPBC
89Good match
ParameterOriginalReplacementDeviation
Voc39.13 V39.3 V0.4%
Vmpp32.84 V32.82 V0.1%
Isc14.15 A14.23 A0.6%
Impp13.1 A13.41 A2.4%
TcVoc-0.23 %/°C-0.23 %/°C±0.000 %/°C
TcPmax-0.29 %/°C-0.28 %/°C±0.010 %/°C
LONGi LR5-54HTH-425M

425 W

HPBC
89Good match
ParameterOriginalReplacementDeviation
Voc39.13 V38.93 V0.5%
Vmpp32.84 V32.64 V0.6%
Isc14.15 A14.07 A0.6%
Impp13.1 A13.03 A0.5%
TcVoc-0.23 %/°C-0.23 %/°C±0.000 %/°C
TcPmax-0.29 %/°C-0.29 %/°C±0.000 %/°C
Maysun Solar MS425BC-54H

425 W

IBC
89Good match
ParameterOriginalReplacementDeviation
Voc39.13 V38.93 V0.5%
Vmpp32.84 V32.64 V0.6%
Isc14.15 A14.07 A0.6%
Impp13.1 A13.03 A0.5%
TcVoc-0.23 %/°C-0.23 %/°C±0.000 %/°C
TcPmax-0.29 %/°C-0.29 %/°C±0.000 %/°C
Hanersun HN18N-54H445W

445 W

TOPCon
85Good match
ParameterOriginalReplacementDeviation
Voc39.13 V38.9 V0.6%
Vmpp32.84 V32.9 V0.2%
Isc14.15 A14.33 A1.3%
Impp13.1 A13.53 A3.3%
TcVoc-0.23 %/°C-0.23 %/°C±0.000 %/°C
TcPmax-0.29 %/°C-0.28 %/°C±0.010 %/°C

String Compatibility Calculator

Verify the replacement panel works with your inverter

Panel Matcher

Find all compatible panels for a specific inverter

Already have panels?

Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.

How the Algorithm Works

Learn how panels are scored and matched

Original Panel Specs

Voc

39.13 V

Vmpp

32.84 V

Isc

14.15 A

Impp

13.1 A

TcVoc

-0.23 %/°C

TcPmax

-0.29 %/°C

Pmax

430 W

Cells

108

Length

1722 mm

Width

1134 mm

Thickness

30 mm

Weight

20.8 kg

The LONGi LR5-54HTH-430M is a 430 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.

Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.

Other models in this series

ModelPowerVocIsc
LR5-54HTH-420M420 W38.73 V14 A
LR5-54HTH-425M425 W38.93 V14.07 A
LR5-54HTH-435M435 W39.33 V14.22 A
LR5-54HTH-440M440 W39.53 V14.3 A
LR5-54HTH-445M445 W39.73 V14.37 A
LR5-54HTH-450M450 W39.93 V14.45 A
LR5-54HTH-455M455 W40.13 V14.52 A

Frequently Asked Questions

What specs must match when replacing the LONGi LR5-54HTH-430M?

The most critical specs to match are: cell count (must be exactly 108), Voc close to 39.13 V (within ±5%), and temperature coefficient TcVoc close to -0.23%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.

Can I use a higher wattage replacement for the LONGi LR5-54HTH-430M?

A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.

What happens if the replacement panel has different voltage specs?

If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original LONGi LR5-54HTH-430M.