590 W HPBC solar panel with 144 cells. Voc 52.6 V · Isc 14.26 A · TcVoc -0.23%/°C.
Select the panel you want to replace
221 panels found · 4118 panels excluded
585 W
HPBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52.6 V | 52.45 V | 0.3% |
| Vmpp | 44.15 V | 44 V | 0.3% |
| Isc | 14.26 A | 14.19 A | 0.5% |
| Impp | 13.37 A | 13.3 A | 0.5% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0.000 %/°C |
| TcPmax | -0.28 %/°C | -0.28 %/°C | ±0.000 %/°C |
585 W
HPBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52.6 V | 52.45 V | 0.3% |
| Vmpp | 44.15 V | 44 V | 0.3% |
| Isc | 14.26 A | 14.19 A | 0.5% |
| Impp | 13.37 A | 13.3 A | 0.5% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0.000 %/°C |
| TcPmax | -0.28 %/°C | -0.28 %/°C | ±0.000 %/°C |
600 W
HPBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52.6 V | 52.51 V | 0.2% |
| Vmpp | 44.15 V | 44.19 V | 0.1% |
| Isc | 14.26 A | 14.55 A | 2.0% |
| Impp | 13.37 A | 13.58 A | 1.6% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0.000 %/°C |
| TcPmax | -0.28 %/°C | -0.28 %/°C | ±0.000 %/°C |
605 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52.6 V | 52.65 V | 0.1% |
| Vmpp | 44.15 V | 43.94 V | 0.5% |
| Isc | 14.26 A | 14.55 A | 2.0% |
| Impp | 13.37 A | 13.77 A | 3.0% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0.000 %/°C |
| TcPmax | -0.28 %/°C | -0.28 %/°C | ±0.000 %/°C |
605 W
HPBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52.6 V | 52.66 V | 0.1% |
| Vmpp | 44.15 V | 44.33 V | 0.4% |
| Isc | 14.26 A | 14.62 A | 2.5% |
| Impp | 13.37 A | 13.65 A | 2.1% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0.000 %/°C |
| TcPmax | -0.28 %/°C | -0.28 %/°C | ±0.000 %/°C |
605 W
HPBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52.6 V | 52.33 V | 0.5% |
| Vmpp | 44.15 V | 44.23 V | 0.2% |
| Isc | 14.26 A | 14.57 A | 2.2% |
| Impp | 13.37 A | 13.68 A | 2.3% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0.000 %/°C |
| TcPmax | -0.28 %/°C | -0.28 %/°C | ±0.000 %/°C |
610 W
HPBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52.6 V | 52.44 V | 0.3% |
| Vmpp | 44.15 V | 44.34 V | 0.4% |
| Isc | 14.26 A | 14.65 A | 2.7% |
| Impp | 13.37 A | 13.76 A | 2.9% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0.000 %/°C |
| TcPmax | -0.28 %/°C | -0.28 %/°C | ±0.000 %/°C |
585 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52.6 V | 52.5 V | 0.2% |
| Vmpp | 44.15 V | 44.1 V | 0.1% |
| Isc | 14.26 A | 13.9 A | 2.5% |
| Impp | 13.37 A | 13.27 A | 0.7% |
| TcVoc | -0.23 %/°C | -0.24 %/°C | ±0.010 %/°C |
| TcPmax | -0.28 %/°C | -0.28 %/°C | ±0.000 %/°C |
590 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52.6 V | 52.7 V | 0.2% |
| Vmpp | 44.15 V | 44.27 V | 0.3% |
| Isc | 14.26 A | 13.95 A | 2.2% |
| Impp | 13.37 A | 13.33 A | 0.3% |
| TcVoc | -0.23 %/°C | -0.24 %/°C | ±0.010 %/°C |
| TcPmax | -0.28 %/°C | -0.28 %/°C | ±0.000 %/°C |
600 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52.6 V | 52.44 V | 0.3% |
| Vmpp | 44.15 V | 43.76 V | 0.9% |
| Isc | 14.26 A | 14.48 A | 1.5% |
| Impp | 13.37 A | 13.71 A | 2.5% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0.000 %/°C |
| TcPmax | -0.28 %/°C | -0.28 %/°C | ±0.000 %/°C |
580 W
HPBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52.6 V | 52.3 V | 0.6% |
| Vmpp | 44.15 V | 43.85 V | 0.7% |
| Isc | 14.26 A | 14.13 A | 0.9% |
| Impp | 13.37 A | 13.23 A | 1.0% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0.000 %/°C |
| TcPmax | -0.28 %/°C | -0.28 %/°C | ±0.000 %/°C |
580 W
HPBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52.6 V | 52.3 V | 0.6% |
| Vmpp | 44.15 V | 43.85 V | 0.7% |
| Isc | 14.26 A | 14.13 A | 0.9% |
| Impp | 13.37 A | 13.23 A | 1.0% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0.000 %/°C |
| TcPmax | -0.28 %/°C | -0.28 %/°C | ±0.000 %/°C |
String Compatibility Calculator
Verify the replacement panel works with your inverter
Panel Matcher
Find all compatible panels for a specific inverter
Already have panels?
Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.
How the Algorithm Works
Learn how panels are scored and matched
Voc
52.6 V
Vmpp
44.15 V
Isc
14.26 A
Impp
13.37 A
TcVoc
-0.23 %/°C
TcPmax
-0.28 %/°C
Pmax
590 W
Cells
144
Bifaciality
60%
Length
2278 mm
Width
1134 mm
Thickness
30 mm
Weight
31.8 kg
The LONGi LR5-72HTDR-590M is a 590 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.
Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.
| Model | Power | Voc | Isc |
|---|---|---|---|
| LR5-72HTDR-565M | 565 W | 51.85 V | 13.93 A |
| LR5-72HTDR-570M | 570 W | 52 V | 14 A |
| LR5-72HTDR-575M | 575 W | 52.15 V | 14.06 A |
| LR5-72HTDR-580M | 580 W | 52.3 V | 14.13 A |
| LR5-72HTDR-585M | 585 W | 52.45 V | 14.19 A |
The most critical specs to match are: cell count (must be exactly 144), Voc close to 52.6 V (within ±5%), and temperature coefficient TcVoc close to -0.23%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.
A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.
If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original LONGi LR5-72HTDR-590M.