555 W HPBC solar panel with 120 cells. Voc 45.45 V · Isc 15.4 A · TcVoc -0.2%/°C.
Select the panel you want to replace
12 panels found · 4327 panels excluded
550 W
HPBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 45.45 V | 45.35 V | 0.2% |
| Vmpp | 37.67 V | 37.57 V | 0.3% |
| Isc | 15.4 A | 15.3 A | 0.6% |
| Impp | 14.73 A | 14.64 A | 0.6% |
| TcVoc | -0.2 %/°C | -0.2 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
545 W
HPBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 45.45 V | 45.25 V | 0.4% |
| Vmpp | 37.67 V | 37.47 V | 0.5% |
| Isc | 15.4 A | 15.2 A | 1.3% |
| Impp | 14.73 A | 14.55 A | 1.2% |
| TcVoc | -0.2 %/°C | -0.2 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
540 W
HPBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 45.45 V | 45.15 V | 0.7% |
| Vmpp | 37.67 V | 37.37 V | 0.8% |
| Isc | 15.4 A | 15.1 A | 1.9% |
| Impp | 14.73 A | 14.45 A | 1.9% |
| TcVoc | -0.2 %/°C | -0.2 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
535 W
HPBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 45.45 V | 45.05 V | 0.9% |
| Vmpp | 37.67 V | 37.27 V | 1.1% |
| Isc | 15.4 A | 15 A | 2.6% |
| Impp | 14.73 A | 14.36 A | 2.5% |
| TcVoc | -0.2 %/°C | -0.2 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
550 W
ABC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 45.45 V | 45.28 V | 0.4% |
| Vmpp | 37.67 V | 38.19 V | 1.4% |
| Isc | 15.4 A | 15.25 A | 1.0% |
| Impp | 14.73 A | 14.41 A | 2.2% |
| TcVoc | -0.2 %/°C | -0.22 %/°C | ±0.020 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
545 W
ABC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 45.45 V | 45.18 V | 0.6% |
| Vmpp | 37.67 V | 38.09 V | 1.1% |
| Isc | 15.4 A | 15.19 A | 1.4% |
| Impp | 14.73 A | 14.31 A | 2.9% |
| TcVoc | -0.2 %/°C | -0.22 %/°C | ±0.020 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
540 W
ABC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 45.45 V | 45.08 V | 0.8% |
| Vmpp | 37.67 V | 37.99 V | 0.8% |
| Isc | 15.4 A | 15.13 A | 1.8% |
| Impp | 14.73 A | 14.22 A | 3.5% |
| TcVoc | -0.2 %/°C | -0.22 %/°C | ±0.020 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
535 W
ABC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 45.45 V | 44.98 V | 1.0% |
| Vmpp | 37.67 V | 37.89 V | 0.6% |
| Isc | 15.4 A | 15.07 A | 2.1% |
| Impp | 14.73 A | 14.13 A | 4.1% |
| TcVoc | -0.2 %/°C | -0.22 %/°C | ±0.020 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
575 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 45.45 V | 45.27 V | 0.4% |
| Vmpp | 37.67 V | 37.62 V | 0.1% |
| Isc | 15.4 A | 16.14 A | 4.8% |
| Impp | 14.73 A | 15.28 A | 3.7% |
| TcVoc | -0.2 %/°C | -0.23 %/°C | ±0.030 %/°C |
| TcPmax | -0.26 %/°C | -0.28 %/°C | ±0.020 %/°C |
570 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 45.45 V | 45.05 V | 0.9% |
| Vmpp | 37.67 V | 37.44 V | 0.6% |
| Isc | 15.4 A | 16.08 A | 4.4% |
| Impp | 14.73 A | 15.22 A | 3.3% |
| TcVoc | -0.2 %/°C | -0.23 %/°C | ±0.030 %/°C |
| TcPmax | -0.26 %/°C | -0.28 %/°C | ±0.020 %/°C |
565 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 45.45 V | 44.83 V | 1.4% |
| Vmpp | 37.67 V | 37.26 V | 1.1% |
| Isc | 15.4 A | 16.01 A | 4.0% |
| Impp | 14.73 A | 15.16 A | 2.9% |
| TcVoc | -0.2 %/°C | -0.23 %/°C | ±0.030 %/°C |
| TcPmax | -0.26 %/°C | -0.28 %/°C | ±0.020 %/°C |
560 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 45.45 V | 44.62 V | 1.8% |
| Vmpp | 37.67 V | 37.08 V | 1.6% |
| Isc | 15.4 A | 15.95 A | 3.6% |
| Impp | 14.73 A | 15.1 A | 2.5% |
| TcVoc | -0.2 %/°C | -0.23 %/°C | ±0.030 %/°C |
| TcPmax | -0.26 %/°C | -0.28 %/°C | ±0.020 %/°C |
String Compatibility Calculator
Verify the replacement panel works with your inverter
Panel Matcher
Find all compatible panels for a specific inverter
Already have panels?
Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.
How the Algorithm Works
Learn how panels are scored and matched
Voc
45.45 V
Vmpp
37.67 V
Isc
15.4 A
Impp
14.73 A
TcVoc
-0.2 %/°C
TcPmax
-0.26 %/°C
Pmax
555 W
Cells
120
Bifaciality
70%
Length
1990 mm
Width
1134 mm
Thickness
30 mm
Weight
28 kg
The LONGi LR7-60HVD-555M is a 555 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.
Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.
| Model | Power | Voc | Isc |
|---|---|---|---|
| LR7-60HVD-530M | 530 W | 44.95 V | 14.9 A |
| LR7-60HVD-535M | 535 W | 45.05 V | 15 A |
| LR7-60HVD-540M | 540 W | 45.15 V | 15.1 A |
| LR7-60HVD-545M | 545 W | 45.25 V | 15.2 A |
| LR7-60HVD-550M | 550 W | 45.35 V | 15.3 A |
The most critical specs to match are: cell count (must be exactly 120), Voc close to 45.45 V (within ±5%), and temperature coefficient TcVoc close to -0.2%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.
A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.
If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original LONGi LR7-60HVD-555M.