Solar Stack
Solar Stack
How it worksGuidesAdd Equipment
Sign in
Solar Stack

Free solar panel & inverter compatibility checker. Verify your PV string configuration is safe before installation.

Tools

  • Calculator
  • Panel Matcher
  • Inverter Finder
  • Inverter Compare
  • Panel Replacement
  • Cable sizing

Resources

  • Guides
  • How it works
  • Standards & Compliance
  • Data API
  • Replacement methodology
  • Add Equipment
  • Feedback

Legal

  • About
  • Privacy Policy
  • Terms of Service
  • Cookie Policy

© 2026 Solar Stack

All replacements

Find replacement for LONGi LR7-60HVH-535M

535 W HPBC solar panel with 120 cells. Voc 44.68 V · Isc 15.05 A · TcVoc -0.2%/°C.

Select the panel you want to replace

Show only panels with matching cell technology

Compatible Replacements

36 panels found · 4303 panels excluded

LONGi LR7-60HVHL-535M

535 W

HPBC
94Good match
ParameterOriginalReplacementDeviation
Voc44.68 V44.78 V0.2%
Vmpp36.91 V37.01 V0.3%
Isc15.05 A15.15 A0.7%
Impp14.36 A14.46 A0.7%
TcVoc-0.2 %/°C-0.2 %/°C±0.000 %/°C
TcPmax-0.26 %/°C-0.26 %/°C±0.000 %/°C
LONGi LR7-60HVH-540M

540 W

HPBC
94Good match
ParameterOriginalReplacementDeviation
Voc44.68 V44.78 V0.2%
Vmpp36.91 V37.01 V0.3%
Isc15.05 A15.15 A0.7%
Impp14.36 A14.46 A0.7%
TcVoc-0.2 %/°C-0.2 %/°C±0.000 %/°C
TcPmax-0.26 %/°C-0.26 %/°C±0.000 %/°C
LONGi LR7-60HVHL-540M

540 W

HPBC
89Good match
ParameterOriginalReplacementDeviation
Voc44.68 V44.88 V0.4%
Vmpp36.91 V37.11 V0.5%
Isc15.05 A15.25 A1.3%
Impp14.36 A14.55 A1.3%
TcVoc-0.2 %/°C-0.2 %/°C±0.000 %/°C
TcPmax-0.26 %/°C-0.26 %/°C±0.000 %/°C
LONGi LR7-60HVHL-545M

545 W

HPBC
83Good match
ParameterOriginalReplacementDeviation
Voc44.68 V44.98 V0.7%
Vmpp36.91 V37.21 V0.8%
Isc15.05 A15.35 A2.0%
Impp14.36 A14.65 A2.0%
TcVoc-0.2 %/°C-0.2 %/°C±0.000 %/°C
TcPmax-0.26 %/°C-0.26 %/°C±0.000 %/°C
LONGi LR7-60HVH-545M

545 W

HPBC
83Good match
ParameterOriginalReplacementDeviation
Voc44.68 V44.98 V0.7%
Vmpp36.91 V37.21 V0.8%
Isc15.05 A15.35 A2.0%
Impp14.36 A14.65 A2.0%
TcVoc-0.2 %/°C-0.2 %/°C±0.000 %/°C
TcPmax-0.26 %/°C-0.26 %/°C±0.000 %/°C
LONGi LR7-60HVH-550M

550 W

HPBC
77Acceptable
ParameterOriginalReplacementDeviation
Voc44.68 V45.08 V0.9%
Vmpp36.91 V37.31 V1.1%
Isc15.05 A15.45 A2.7%
Impp14.36 A14.74 A2.6%
TcVoc-0.2 %/°C-0.2 %/°C±0.000 %/°C
TcPmax-0.26 %/°C-0.26 %/°C±0.000 %/°C
LONGi LR7-60HVHL-550M

550 W

HPBC
77Acceptable
ParameterOriginalReplacementDeviation
Voc44.68 V45.08 V0.9%
Vmpp36.91 V37.31 V1.1%
Isc15.05 A15.45 A2.7%
Impp14.36 A14.74 A2.6%
TcVoc-0.2 %/°C-0.2 %/°C±0.000 %/°C
TcPmax-0.26 %/°C-0.26 %/°C±0.000 %/°C
LONGi LR7-60HVH-555M

555 W

HPBC
71Acceptable
ParameterOriginalReplacementDeviation
Voc44.68 V45.18 V1.1%
Vmpp36.91 V37.41 V1.4%
Isc15.05 A15.55 A3.3%
Impp14.36 A14.84 A3.3%
TcVoc-0.2 %/°C-0.2 %/°C±0.000 %/°C
TcPmax-0.26 %/°C-0.26 %/°C±0.000 %/°C
LONGi LR7-60HVHL-555M

555 W

HPBC
71Acceptable
ParameterOriginalReplacementDeviation
Voc44.68 V45.18 V1.1%
Vmpp36.91 V37.41 V1.4%
Isc15.05 A15.55 A3.3%
Impp14.36 A14.84 A3.3%
TcVoc-0.2 %/°C-0.2 %/°C±0.000 %/°C
TcPmax-0.26 %/°C-0.26 %/°C±0.000 %/°C
Aiko Solar AIKO-A540-MCE60Dw

540 W

ABC
64Acceptable
ParameterOriginalReplacementDeviation
Voc44.68 V45.08 V0.9%
Vmpp36.91 V37.99 V2.9%
Isc15.05 A15.13 A0.5%
Impp14.36 A14.22 A1.0%
TcVoc-0.2 %/°C-0.22 %/°C±0.020 %/°C
TcPmax-0.26 %/°C-0.26 %/°C±0.000 %/°C
Aiko Solar AIKO-A545-MCE60Dw

545 W

ABC
60Acceptable
ParameterOriginalReplacementDeviation
Voc44.68 V45.18 V1.1%
Vmpp36.91 V38.09 V3.2%
Isc15.05 A15.19 A0.9%
Impp14.36 A14.31 A0.3%
TcVoc-0.2 %/°C-0.22 %/°C±0.020 %/°C
TcPmax-0.26 %/°C-0.26 %/°C±0.000 %/°C
Aiko Solar AIKO-A550-MCE60Dw

550 W

ABC
55Marginal
ParameterOriginalReplacementDeviation
Voc44.68 V45.28 V1.3%
Vmpp36.91 V38.19 V3.5%
Isc15.05 A15.25 A1.3%
Impp14.36 A14.41 A0.3%
TcVoc-0.2 %/°C-0.22 %/°C±0.020 %/°C
TcPmax-0.26 %/°C-0.26 %/°C±0.000 %/°C

String Compatibility Calculator

Verify the replacement panel works with your inverter

Panel Matcher

Find all compatible panels for a specific inverter

Already have panels?

Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.

How the Algorithm Works

Learn how panels are scored and matched

Original Panel Specs

Voc

44.68 V

Vmpp

36.91 V

Isc

15.05 A

Impp

14.36 A

TcVoc

-0.2 %/°C

TcPmax

-0.26 %/°C

Pmax

535 W

Cells

120

Length

1990 mm

Width

1134 mm

Thickness

30 mm

Weight

25.3 kg

The LONGi LR7-60HVH-535M is a 535 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.

Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.

Other models in this series

ModelPowerVocIsc
LR7-60HVH-540M540 W44.78 V15.15 A
LR7-60HVH-545M545 W44.98 V15.35 A
LR7-60HVH-550M550 W45.08 V15.45 A
LR7-60HVH-555M555 W45.18 V15.55 A
LR7-60HVH-560M560 W45.28 V15.65 A

Frequently Asked Questions

What specs must match when replacing the LONGi LR7-60HVH-535M?

The most critical specs to match are: cell count (must be exactly 120), Voc close to 44.68 V (within ±5%), and temperature coefficient TcVoc close to -0.2%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.

Can I use a higher wattage replacement for the LONGi LR7-60HVH-535M?

A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.

What happens if the replacement panel has different voltage specs?

If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original LONGi LR7-60HVH-535M.