620 W HPBC solar panel with 144 cells. Voc 53.11 V · Isc 14.82 A · TcVoc -0.23%/°C.
Select the panel you want to replace
79 panels found · 4260 panels excluded
615 W
HPBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 53.11 V | 52.96 V | 0.3% |
| Vmpp | 44.78 V | 44.63 V | 0.3% |
| Isc | 14.82 A | 14.75 A | 0.5% |
| Impp | 13.85 A | 13.78 A | 0.5% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0.000 %/°C |
| TcPmax | -0.28 %/°C | -0.28 %/°C | ±0.000 %/°C |
625 W
HPBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 53.11 V | 53.26 V | 0.3% |
| Vmpp | 44.78 V | 44.93 V | 0.3% |
| Isc | 14.82 A | 14.9 A | 0.5% |
| Impp | 13.85 A | 13.92 A | 0.5% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0.000 %/°C |
| TcPmax | -0.28 %/°C | -0.28 %/°C | ±0.000 %/°C |
625 W
HPBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 53.11 V | 52.88 V | 0.4% |
| Vmpp | 44.78 V | 44.44 V | 0.8% |
| Isc | 14.82 A | 14.93 A | 0.7% |
| Impp | 13.85 A | 14.07 A | 1.6% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0.000 %/°C |
| TcPmax | -0.28 %/°C | -0.28 %/°C | ±0.000 %/°C |
610 W
HPBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 53.11 V | 52.81 V | 0.6% |
| Vmpp | 44.78 V | 44.48 V | 0.7% |
| Isc | 14.82 A | 14.69 A | 0.9% |
| Impp | 13.85 A | 13.72 A | 0.9% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0.000 %/°C |
| TcPmax | -0.28 %/°C | -0.28 %/°C | ±0.000 %/°C |
620 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 53.11 V | 52.6 V | 1.0% |
| Vmpp | 44.78 V | 44.8 V | 0.0% |
| Isc | 14.82 A | 14.78 A | 0.3% |
| Impp | 13.85 A | 13.84 A | 0.1% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0.000 %/°C |
| TcPmax | -0.28 %/°C | -0.28 %/°C | ±0.000 %/°C |
620 W
HPBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 53.11 V | 52.77 V | 0.6% |
| Vmpp | 44.78 V | 44.33 V | 1.0% |
| Isc | 14.82 A | 14.85 A | 0.2% |
| Impp | 13.85 A | 13.99 A | 1.0% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0.000 %/°C |
| TcPmax | -0.28 %/°C | -0.28 %/°C | ±0.000 %/°C |
610 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 53.11 V | 52.92 V | 0.4% |
| Vmpp | 44.78 V | 44.16 V | 1.4% |
| Isc | 14.82 A | 14.59 A | 1.6% |
| Impp | 13.85 A | 13.81 A | 0.3% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0.000 %/°C |
| TcPmax | -0.28 %/°C | -0.28 %/°C | ±0.000 %/°C |
615 W
HPBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 53.11 V | 52.55 V | 1.1% |
| Vmpp | 44.78 V | 44.44 V | 0.8% |
| Isc | 14.82 A | 14.73 A | 0.6% |
| Impp | 13.85 A | 13.84 A | 0.1% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0.000 %/°C |
| TcPmax | -0.28 %/°C | -0.28 %/°C | ±0.000 %/°C |
605 W
HPBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 53.11 V | 52.66 V | 0.8% |
| Vmpp | 44.78 V | 44.33 V | 1.0% |
| Isc | 14.82 A | 14.62 A | 1.3% |
| Impp | 13.85 A | 13.65 A | 1.4% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0.000 %/°C |
| TcPmax | -0.28 %/°C | -0.28 %/°C | ±0.000 %/°C |
615 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 53.11 V | 52.4 V | 1.3% |
| Vmpp | 44.78 V | 44.6 V | 0.4% |
| Isc | 14.82 A | 14.72 A | 0.7% |
| Impp | 13.85 A | 13.79 A | 0.4% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0.000 %/°C |
| TcPmax | -0.28 %/°C | -0.28 %/°C | ±0.000 %/°C |
600 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 53.11 V | 53.28 V | 0.3% |
| Vmpp | 44.78 V | 44.75 V | 0.1% |
| Isc | 14.82 A | 14.2 A | 4.2% |
| Impp | 13.85 A | 13.41 A | 3.2% |
| TcVoc | -0.23 %/°C | -0.24 %/°C | ±0.010 %/°C |
| TcPmax | -0.28 %/°C | -0.29 %/°C | ±0.010 %/°C |
610 W
HPBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 53.11 V | 52.44 V | 1.3% |
| Vmpp | 44.78 V | 44.34 V | 1.0% |
| Isc | 14.82 A | 14.65 A | 1.1% |
| Impp | 13.85 A | 13.76 A | 0.6% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0.000 %/°C |
| TcPmax | -0.28 %/°C | -0.28 %/°C | ±0.000 %/°C |
String Compatibility Calculator
Verify the replacement panel works with your inverter
Panel Matcher
Find all compatible panels for a specific inverter
Already have panels?
Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.
How the Algorithm Works
Learn how panels are scored and matched
Voc
53.11 V
Vmpp
44.78 V
Isc
14.82 A
Impp
13.85 A
TcVoc
-0.23 %/°C
TcPmax
-0.28 %/°C
Pmax
620 W
Cells
144
Bifaciality
60%
Length
2382 mm
Width
1134 mm
Thickness
30 mm
Weight
33.5 kg
The LONGi LR7-72HTDR-620M is a 620 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.
Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.
| Model | Power | Voc | Isc |
|---|---|---|---|
| LR7-72HTDR-600M | 600 W | 52.51 V | 14.55 A |
| LR7-72HTDR-605M | 605 W | 52.66 V | 14.62 A |
| LR7-72HTDR-610M | 610 W | 52.81 V | 14.69 A |
| LR7-72HTDR-615M | 615 W | 52.96 V | 14.75 A |
| LR7-72HTDR-625M | 625 W | 53.26 V | 14.9 A |
The most critical specs to match are: cell count (must be exactly 144), Voc close to 53.11 V (within ±5%), and temperature coefficient TcVoc close to -0.23%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.
A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.
If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original LONGi LR7-72HTDR-620M.