670 W HPBC solar panel with 144 cells. Voc 54.3 V · Isc 15.6 A · TcVoc -0.2%/°C.
Select the panel you want to replace
Voc
54.3 V
Vmpp
44.96 V
Isc
15.6 A
Impp
14.91 A
TcVoc
-0.2 %/°C
TcPmax
-0.26 %/°C
Pmax
670 W
Cells
144
The LONGi LR7-72HVHF-670M is a 670 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.
Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.
| Model | Power | Voc | Isc |
|---|---|---|---|
| 640 W | 53.7 V | 15.13 A | |
| 645 W | 53.8 V | 15.21 A | |
| 655 W | 54 V | 15.37 A | |
| 660 W | 54.1 V | 15.45 A | |
| 665 W | 54.2 V | 15.52 A |
The most critical specs to match are: cell count (must be exactly 144), Voc close to 54.3 V (within ±5%), and temperature coefficient TcVoc close to -0.2%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.
A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.
If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original LONGi LR7-72HVHF-670M.