645 W HPBC solar panel with 132 cells. Voc 49.62 V · Isc 16.46 A · TcVoc -0.2%/°C.
Select the panel you want to replace
87 panels found · 4252 panels excluded
645 W
HPBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.62 V | 49.62 V | 0.0% |
| Vmpp | 40.88 V | 40.88 V | 0.0% |
| Isc | 16.46 A | 16.46 A | 0.0% |
| Impp | 15.78 A | 15.78 A | 0.0% |
| TcVoc | -0.2 %/°C | -0.2 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
645 W
HPBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.62 V | 49.62 V | 0.0% |
| Vmpp | 40.88 V | 40.88 V | 0.0% |
| Isc | 16.46 A | 16.46 A | 0.0% |
| Impp | 15.78 A | 15.78 A | 0.0% |
| TcVoc | -0.2 %/°C | -0.2 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
640 W
HPBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.62 V | 49.52 V | 0.2% |
| Vmpp | 40.88 V | 40.78 V | 0.2% |
| Isc | 16.46 A | 16.38 A | 0.5% |
| Impp | 15.78 A | 15.69 A | 0.6% |
| TcVoc | -0.2 %/°C | -0.2 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
645 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.62 V | 49.52 V | 0.2% |
| Vmpp | 40.88 V | 40.9 V | 0.0% |
| Isc | 16.46 A | 16.44 A | 0.1% |
| Impp | 15.78 A | 15.78 A | 0.0% |
| TcVoc | -0.2 %/°C | -0.2 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.27 %/°C | ±0.010 %/°C |
650 W
HPBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.62 V | 49.72 V | 0.2% |
| Vmpp | 40.88 V | 40.98 V | 0.2% |
| Isc | 16.46 A | 16.54 A | 0.5% |
| Impp | 15.78 A | 15.86 A | 0.5% |
| TcVoc | -0.2 %/°C | -0.2 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
640 W
HPBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.62 V | 49.52 V | 0.2% |
| Vmpp | 40.88 V | 40.78 V | 0.2% |
| Isc | 16.46 A | 16.38 A | 0.5% |
| Impp | 15.78 A | 15.69 A | 0.6% |
| TcVoc | -0.2 %/°C | -0.2 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
640 W
HPBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.62 V | 49.52 V | 0.2% |
| Vmpp | 40.88 V | 40.78 V | 0.2% |
| Isc | 16.46 A | 16.38 A | 0.5% |
| Impp | 15.78 A | 15.69 A | 0.6% |
| TcVoc | -0.2 %/°C | -0.2 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
650 W
HPBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.62 V | 49.72 V | 0.2% |
| Vmpp | 40.88 V | 40.98 V | 0.2% |
| Isc | 16.46 A | 16.54 A | 0.5% |
| Impp | 15.78 A | 15.86 A | 0.5% |
| TcVoc | -0.2 %/°C | -0.2 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
650 W
HPBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.62 V | 49.72 V | 0.2% |
| Vmpp | 40.88 V | 40.98 V | 0.2% |
| Isc | 16.46 A | 16.54 A | 0.5% |
| Impp | 15.78 A | 15.86 A | 0.5% |
| TcVoc | -0.2 %/°C | -0.2 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
650 W
IBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.62 V | 49.54 V | 0.2% |
| Vmpp | 40.88 V | 40.83 V | 0.1% |
| Isc | 16.46 A | 16.7 A | 1.5% |
| Impp | 15.78 A | 15.92 A | 0.9% |
| TcVoc | -0.2 %/°C | -0.2 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
655 W
IBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.62 V | 49.64 V | 0.0% |
| Vmpp | 40.88 V | 40.93 V | 0.1% |
| Isc | 16.46 A | 16.78 A | 1.9% |
| Impp | 15.78 A | 16 A | 1.4% |
| TcVoc | -0.2 %/°C | -0.2 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
650 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.62 V | 49.66 V | 0.1% |
| Vmpp | 40.88 V | 41.02 V | 0.3% |
| Isc | 16.46 A | 16.51 A | 0.3% |
| Impp | 15.78 A | 15.85 A | 0.4% |
| TcVoc | -0.2 %/°C | -0.2 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.27 %/°C | ±0.010 %/°C |
String Compatibility Calculator
Verify the replacement panel works with your inverter
Panel Matcher
Find all compatible panels for a specific inverter
Already have panels?
Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.
How the Algorithm Works
Learn how panels are scored and matched
Voc
49.62 V
Vmpp
40.88 V
Isc
16.46 A
Impp
15.78 A
TcVoc
-0.2 %/°C
TcPmax
-0.26 %/°C
Pmax
645 W
Cells
132
Bifaciality
75%
Length
2382 mm
Width
1134 mm
Thickness
30 mm
Weight
35 kg
The LONGi LR8-66HYD-645M is a 645 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.
Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.
| Model | Power | Voc | Isc |
|---|---|---|---|
| LR8-66HYD-630M | 630 W | 49.32 V | 16.22 A |
| LR8-66HYD-635M | 635 W | 49.42 V | 16.3 A |
| LR8-66HYD-640M | 640 W | 49.52 V | 16.38 A |
| LR8-66HYD-650M | 650 W | 49.72 V | 16.54 A |
| LR8-66HYD-655M | 655 W | 49.82 V | 16.62 A |
| LR8-66HYD-660M | 660 W | 49.92 V | 16.7 A |
| LR8-66HYD-665M | 665 W | 50.02 V | 16.78 A |
| LR8-66HYD-670M | 670 W | 50.12 V | 16.86 A |
The most critical specs to match are: cell count (must be exactly 132), Voc close to 49.62 V (within ±5%), and temperature coefficient TcVoc close to -0.2%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.
A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.
If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original LONGi LR8-66HYD-645M.