465 W PERC solar panel with 120 cells. Voc 41.72 V · Isc 13.99 A · TcVoc -0.27%/°C.
Select the panel you want to replace
36 panels found · 4303 panels excluded
465 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 41.72 V | 41.72 V | 0.0% |
| Vmpp | 34.31 V | 34.31 V | 0.0% |
| Isc | 13.99 A | 13.99 A | 0.0% |
| Impp | 13.55 A | 13.55 A | 0.0% |
| TcVoc | -0.27 %/°C | -0.27 %/°C | ±0.000 %/°C |
| TcPmax | -0.33 %/°C | -0.33 %/°C | ±0.000 %/°C |
460 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 41.72 V | 41.55 V | 0.4% |
| Vmpp | 34.31 V | 34.15 V | 0.5% |
| Isc | 13.99 A | 13.94 A | 0.4% |
| Impp | 13.55 A | 13.47 A | 0.6% |
| TcVoc | -0.27 %/°C | -0.27 %/°C | ±0.000 %/°C |
| TcPmax | -0.33 %/°C | -0.33 %/°C | ±0.000 %/°C |
460 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 41.72 V | 41.55 V | 0.4% |
| Vmpp | 34.31 V | 34.15 V | 0.5% |
| Isc | 13.99 A | 13.94 A | 0.4% |
| Impp | 13.55 A | 13.47 A | 0.6% |
| TcVoc | -0.27 %/°C | -0.27 %/°C | ±0.000 %/°C |
| TcPmax | -0.33 %/°C | -0.33 %/°C | ±0.000 %/°C |
455 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 41.72 V | 41.38 V | 0.8% |
| Vmpp | 34.31 V | 33.99 V | 0.9% |
| Isc | 13.99 A | 13.89 A | 0.7% |
| Impp | 13.55 A | 13.39 A | 1.2% |
| TcVoc | -0.27 %/°C | -0.27 %/°C | ±0.000 %/°C |
| TcPmax | -0.33 %/°C | -0.33 %/°C | ±0.000 %/°C |
455 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 41.72 V | 41.38 V | 0.8% |
| Vmpp | 34.31 V | 33.99 V | 0.9% |
| Isc | 13.99 A | 13.89 A | 0.7% |
| Impp | 13.55 A | 13.39 A | 1.2% |
| TcVoc | -0.27 %/°C | -0.27 %/°C | ±0.000 %/°C |
| TcPmax | -0.33 %/°C | -0.33 %/°C | ±0.000 %/°C |
455 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 41.72 V | 41.7 V | 0.0% |
| Vmpp | 34.31 V | 35.06 V | 2.2% |
| Isc | 13.99 A | 13.75 A | 1.7% |
| Impp | 13.55 A | 12.98 A | 4.2% |
| TcVoc | -0.27 %/°C | -0.27 %/°C | ±0.000 %/°C |
| TcPmax | -0.33 %/°C | -0.34 %/°C | ±0.010 %/°C |
450 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 41.72 V | 41.5 V | 0.5% |
| Vmpp | 34.31 V | 34.81 V | 1.5% |
| Isc | 13.99 A | 13.7 A | 2.1% |
| Impp | 13.55 A | 12.93 A | 4.6% |
| TcVoc | -0.27 %/°C | -0.27 %/°C | ±0.000 %/°C |
| TcPmax | -0.33 %/°C | -0.34 %/°C | ±0.010 %/°C |
450 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 41.72 V | 41.21 V | 1.2% |
| Vmpp | 34.31 V | 33.83 V | 1.4% |
| Isc | 13.99 A | 13.84 A | 1.1% |
| Impp | 13.55 A | 13.3 A | 1.8% |
| TcVoc | -0.27 %/°C | -0.27 %/°C | ±0.000 %/°C |
| TcPmax | -0.33 %/°C | -0.33 %/°C | ±0.000 %/°C |
450 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 41.72 V | 41.21 V | 1.2% |
| Vmpp | 34.31 V | 33.83 V | 1.4% |
| Isc | 13.99 A | 13.84 A | 1.1% |
| Impp | 13.55 A | 13.3 A | 1.8% |
| TcVoc | -0.27 %/°C | -0.27 %/°C | ±0.000 %/°C |
| TcPmax | -0.33 %/°C | -0.33 %/°C | ±0.000 %/°C |
455 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 41.72 V | 41.7 V | 0.0% |
| Vmpp | 34.31 V | 34.78 V | 1.4% |
| Isc | 13.99 A | 13.9 A | 0.6% |
| Impp | 13.55 A | 13.09 A | 3.4% |
| TcVoc | -0.27 %/°C | -0.285 %/°C | ±0.015 %/°C |
| TcPmax | -0.33 %/°C | -0.36 %/°C | ±0.030 %/°C |
460 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 41.72 V | 41.9 V | 0.4% |
| Vmpp | 34.31 V | 35.31 V | 2.9% |
| Isc | 13.99 A | 13.8 A | 1.4% |
| Impp | 13.55 A | 13.03 A | 3.8% |
| TcVoc | -0.27 %/°C | -0.27 %/°C | ±0.000 %/°C |
| TcPmax | -0.33 %/°C | -0.34 %/°C | ±0.010 %/°C |
460 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 41.72 V | 41.19 V | 1.3% |
| Vmpp | 34.31 V | 34.51 V | 0.6% |
| Isc | 13.99 A | 13.92 A | 0.5% |
| Impp | 13.55 A | 13.33 A | 1.6% |
| TcVoc | -0.27 %/°C | -0.26 %/°C | ±0.010 %/°C |
| TcPmax | -0.33 %/°C | -0.33 %/°C | ±0.000 %/°C |
String Compatibility Calculator
Verify the replacement panel works with your inverter
Panel Matcher
Find all compatible panels for a specific inverter
Already have panels?
Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.
How the Algorithm Works
Learn how panels are scored and matched
Voc
41.72 V
Vmpp
34.31 V
Isc
13.99 A
Impp
13.55 A
TcVoc
-0.27 %/°C
TcPmax
-0.33 %/°C
Pmax
465 W
Cells
120
Length
1908 mm
Width
1134 mm
Thickness
30 mm
Weight
24.2 kg
The Perlight Solar PLM-465H8M-120 is a 465 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.
Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.
| Model | Power | Voc | Isc |
|---|---|---|---|
| PLM-450H8M-120 | 450 W | 41.21 V | 13.84 A |
| PLM-450H8MB-120 | 450 W | 41.21 V | 13.84 A |
| PLM-455H8MB-120 | 455 W | 41.38 V | 13.89 A |
| PLM-455H8M-120 | 455 W | 41.38 V | 13.89 A |
| PLM-460H8M-120 | 460 W | 41.55 V | 13.94 A |
| PLM-460H8MB-120 | 460 W | 41.55 V | 13.94 A |
| PLM-465H8MB-120 | 465 W | 41.72 V | 13.99 A |
The most critical specs to match are: cell count (must be exactly 120), Voc close to 41.72 V (within ±5%), and temperature coefficient TcVoc close to -0.27%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.
A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.
If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original Perlight Solar PLM-465H8M-120.