555 W PERC solar panel with 144 cells. Voc 50.3 V · Isc 13.93 A · TcVoc -0.27%/°C.
Select the panel you want to replace
128 panels found · 4211 panels excluded
550 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.3 V | 50.1 V | 0.4% |
| Vmpp | 42.16 V | 41.96 V | 0.5% |
| Isc | 13.93 A | 13.88 A | 0.4% |
| Impp | 13.17 A | 13.11 A | 0.5% |
| TcVoc | -0.27 %/°C | -0.27 %/°C | ±0.000 %/°C |
| TcPmax | -0.33 %/°C | -0.33 %/°C | ±0.000 %/°C |
560 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.3 V | 50.5 V | 0.4% |
| Vmpp | 42.16 V | 42.36 V | 0.5% |
| Isc | 13.93 A | 13.98 A | 0.4% |
| Impp | 13.17 A | 13.23 A | 0.5% |
| TcVoc | -0.27 %/°C | -0.27 %/°C | ±0.000 %/°C |
| TcPmax | -0.33 %/°C | -0.33 %/°C | ±0.000 %/°C |
560 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.3 V | 50.15 V | 0.3% |
| Vmpp | 42.16 V | 42.27 V | 0.3% |
| Isc | 13.93 A | 14.14 A | 1.5% |
| Impp | 13.17 A | 13.25 A | 0.6% |
| TcVoc | -0.27 %/°C | -0.275 %/°C | ±0.005 %/°C |
| TcPmax | -0.33 %/°C | -0.35 %/°C | ±0.020 %/°C |
555 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.3 V | 49.95 V | 0.7% |
| Vmpp | 42.16 V | 42.1 V | 0.1% |
| Isc | 13.93 A | 14.05 A | 0.9% |
| Impp | 13.17 A | 13.19 A | 0.2% |
| TcVoc | -0.27 %/°C | -0.265 %/°C | ±0.005 %/°C |
| TcPmax | -0.33 %/°C | -0.34 %/°C | ±0.010 %/°C |
555 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.3 V | 50.03 V | 0.5% |
| Vmpp | 42.16 V | 42.15 V | 0.0% |
| Isc | 13.93 A | 14.07 A | 1.0% |
| Impp | 13.17 A | 13.17 A | 0.0% |
| TcVoc | -0.27 %/°C | -0.275 %/°C | ±0.005 %/°C |
| TcPmax | -0.33 %/°C | -0.35 %/°C | ±0.020 %/°C |
555 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.3 V | 50.08 V | 0.4% |
| Vmpp | 42.16 V | 42.18 V | 0.0% |
| Isc | 13.93 A | 13.93 A | 0.0% |
| Impp | 13.17 A | 13.16 A | 0.1% |
| TcVoc | -0.27 %/°C | -0.28 %/°C | ±0.010 %/°C |
| TcPmax | -0.33 %/°C | -0.35 %/°C | ±0.020 %/°C |
545 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.3 V | 49.9 V | 0.8% |
| Vmpp | 42.16 V | 41.76 V | 0.9% |
| Isc | 13.93 A | 13.83 A | 0.7% |
| Impp | 13.17 A | 13.05 A | 0.9% |
| TcVoc | -0.27 %/°C | -0.27 %/°C | ±0.000 %/°C |
| TcPmax | -0.33 %/°C | -0.33 %/°C | ±0.000 %/°C |
560 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.3 V | 50.1 V | 0.4% |
| Vmpp | 42.16 V | 42.5 V | 0.8% |
| Isc | 13.93 A | 14.1 A | 1.2% |
| Impp | 13.17 A | 13.26 A | 0.7% |
| TcVoc | -0.27 %/°C | -0.265 %/°C | ±0.005 %/°C |
| TcPmax | -0.33 %/°C | -0.34 %/°C | ±0.010 %/°C |
555 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.3 V | 50.02 V | 0.6% |
| Vmpp | 42.16 V | 42.11 V | 0.1% |
| Isc | 13.93 A | 14.07 A | 1.0% |
| Impp | 13.17 A | 13.18 A | 0.1% |
| TcVoc | -0.27 %/°C | -0.275 %/°C | ±0.005 %/°C |
| TcPmax | -0.33 %/°C | -0.35 %/°C | ±0.020 %/°C |
565 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.3 V | 50.39 V | 0.2% |
| Vmpp | 42.16 V | 42.55 V | 0.9% |
| Isc | 13.93 A | 14.2 A | 1.9% |
| Impp | 13.17 A | 13.29 A | 0.9% |
| TcVoc | -0.27 %/°C | -0.275 %/°C | ±0.005 %/°C |
| TcPmax | -0.33 %/°C | -0.3 %/°C | ±0.030 %/°C |
550 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.3 V | 49.9 V | 0.8% |
| Vmpp | 42.16 V | 41.96 V | 0.5% |
| Isc | 13.93 A | 14 A | 0.5% |
| Impp | 13.17 A | 13.11 A | 0.5% |
| TcVoc | -0.27 %/°C | -0.275 %/°C | ±0.005 %/°C |
| TcPmax | -0.33 %/°C | -0.35 %/°C | ±0.020 %/°C |
550 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.3 V | 50.2 V | 0.2% |
| Vmpp | 42.16 V | 41.9 V | 0.6% |
| Isc | 13.93 A | 13.89 A | 0.3% |
| Impp | 13.17 A | 13.13 A | 0.3% |
| TcVoc | -0.27 %/°C | -0.29 %/°C | ±0.020 %/°C |
| TcPmax | -0.33 %/°C | -0.35 %/°C | ±0.020 %/°C |
String Compatibility Calculator
Verify the replacement panel works with your inverter
Panel Matcher
Find all compatible panels for a specific inverter
Already have panels?
Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.
How the Algorithm Works
Learn how panels are scored and matched
Voc
50.3 V
Vmpp
42.16 V
Isc
13.93 A
Impp
13.17 A
TcVoc
-0.27 %/°C
TcPmax
-0.33 %/°C
Pmax
555 W
Cells
144
Bifaciality
70%
Length
2278 mm
Width
1134 mm
Thickness
30 mm
Weight
31.5 kg
The Perlight Solar PLM-555DH8M-144 is a 555 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.
Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.
| Model | Power | Voc | Isc |
|---|---|---|---|
| PLM-540DH8M-144 | 540 W | 49.7 V | 13.78 A |
| PLM-545DH8M-144 | 545 W | 49.9 V | 13.83 A |
| PLM-550DH8M-144 | 550 W | 50.1 V | 13.88 A |
| PLM-560DH8M-144 | 560 W | 50.5 V | 13.98 A |
The most critical specs to match are: cell count (must be exactly 144), Voc close to 50.3 V (within ±5%), and temperature coefficient TcVoc close to -0.27%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.
A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.
If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original Perlight Solar PLM-555DH8M-144.