585 W TOPCon solar panel with 144 cells. Voc 53 V · Isc 13.54 A · TcVoc -0.25%/°C.
Select the panel you want to replace
113 panels found · 4226 panels excluded
580 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 53 V | 52.8 V | 0.4% |
| Vmpp | 45.23 V | 45.03 V | 0.4% |
| Isc | 13.54 A | 13.5 A | 0.3% |
| Impp | 12.94 A | 12.9 A | 0.3% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.3 %/°C | -0.3 %/°C | ±0.000 %/°C |
590 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 53 V | 53.2 V | 0.4% |
| Vmpp | 45.23 V | 45.43 V | 0.4% |
| Isc | 13.54 A | 13.58 A | 0.3% |
| Impp | 12.94 A | 13 A | 0.5% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.3 %/°C | -0.3 %/°C | ±0.000 %/°C |
575 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 53 V | 52.6 V | 0.8% |
| Vmpp | 45.23 V | 44.83 V | 0.9% |
| Isc | 13.54 A | 13.46 A | 0.6% |
| Impp | 12.94 A | 12.83 A | 0.9% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.3 %/°C | -0.3 %/°C | ±0.000 %/°C |
570 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 53 V | 52.4 V | 1.1% |
| Vmpp | 45.23 V | 44.63 V | 1.3% |
| Isc | 13.54 A | 13.42 A | 0.9% |
| Impp | 12.94 A | 12.78 A | 1.2% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.3 %/°C | -0.3 %/°C | ±0.000 %/°C |
595 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 53 V | 52.8 V | 0.4% |
| Vmpp | 45.23 V | 44.1 V | 2.5% |
| Isc | 13.54 A | 14.36 A | 6.1% |
| Impp | 12.94 A | 13.5 A | 4.3% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.3 %/°C | -0.29 %/°C | ±0.010 %/°C |
595 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 53 V | 53.05 V | 0.1% |
| Vmpp | 45.23 V | 43.82 V | 3.1% |
| Isc | 13.54 A | 14.45 A | 6.7% |
| Impp | 12.94 A | 13.58 A | 4.9% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.3 %/°C | -0.29 %/°C | ±0.010 %/°C |
585 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 53 V | 52.48 V | 1.0% |
| Vmpp | 45.23 V | 43.61 V | 3.6% |
| Isc | 13.54 A | 13.67 A | 1.0% |
| Impp | 12.94 A | 13.42 A | 3.7% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.3 %/°C | -0.29 %/°C | ±0.010 %/°C |
590 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 53 V | 52.63 V | 0.7% |
| Vmpp | 45.23 V | 43.71 V | 3.4% |
| Isc | 13.54 A | 14.13 A | 4.4% |
| Impp | 12.94 A | 13.5 A | 4.3% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.3 %/°C | -0.29 %/°C | ±0.010 %/°C |
590 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 53 V | 52.63 V | 0.7% |
| Vmpp | 45.23 V | 43.71 V | 3.4% |
| Isc | 13.54 A | 14.13 A | 4.4% |
| Impp | 12.94 A | 13.5 A | 4.3% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.3 %/°C | -0.29 %/°C | ±0.010 %/°C |
600 W
HPBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 53 V | 52.81 V | 0.4% |
| Vmpp | 45.23 V | 44.66 V | 1.3% |
| Isc | 13.54 A | 14.46 A | 6.8% |
| Impp | 12.94 A | 13.44 A | 3.9% |
| TcVoc | -0.25 %/°C | -0.23 %/°C | ±0.020 %/°C |
| TcPmax | -0.3 %/°C | -0.29 %/°C | ±0.010 %/°C |
590 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 53 V | 52.6 V | 0.8% |
| Vmpp | 45.23 V | 43.9 V | 2.9% |
| Isc | 13.54 A | 14.29 A | 5.5% |
| Impp | 12.94 A | 13.44 A | 3.9% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.3 %/°C | -0.29 %/°C | ±0.010 %/°C |
600 W
IBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 53 V | 52.81 V | 0.4% |
| Vmpp | 45.23 V | 44.66 V | 1.3% |
| Isc | 13.54 A | 14.46 A | 6.8% |
| Impp | 12.94 A | 13.44 A | 3.9% |
| TcVoc | -0.25 %/°C | -0.23 %/°C | ±0.020 %/°C |
| TcPmax | -0.3 %/°C | -0.29 %/°C | ±0.010 %/°C |
String Compatibility Calculator
Verify the replacement panel works with your inverter
Panel Matcher
Find all compatible panels for a specific inverter
Already have panels?
Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.
How the Algorithm Works
Learn how panels are scored and matched
Voc
53 V
Vmpp
45.23 V
Isc
13.54 A
Impp
12.94 A
TcVoc
-0.25 %/°C
TcPmax
-0.3 %/°C
Pmax
585 W
Cells
144
Length
2278 mm
Width
1134 mm
Thickness
35 mm
Weight
27.8 kg
The Perlight Solar PLM-585H8N-144 is a 585 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.
Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.
| Model | Power | Voc | Isc |
|---|---|---|---|
| PLM-570H8N-144 | 570 W | 52.4 V | 13.42 A |
| PLM-575H8N-144 | 575 W | 52.6 V | 13.46 A |
| PLM-580H8N-144 | 580 W | 52.8 V | 13.5 A |
| PLM-590H8N-144 | 590 W | 53.2 V | 13.58 A |
The most critical specs to match are: cell count (must be exactly 144), Voc close to 53 V (within ±5%), and temperature coefficient TcVoc close to -0.25%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.
A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.
If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original Perlight Solar PLM-585H8N-144.