445 W TOPCon solar panel with 108 cells. Voc 39.9 V · Isc 14.18 A · TcVoc -0.25%/°C.
Select the panel you want to replace
193 panels found · 4146 panels excluded
450 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 39.9 V | 39.78 V | 0.3% |
| Vmpp | 33.02 V | 33.22 V | 0.6% |
| Isc | 14.18 A | 14.38 A | 1.4% |
| Impp | 13.48 A | 13.55 A | 0.5% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
450 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 39.9 V | 39.7 V | 0.5% |
| Vmpp | 33.02 V | 33.1 V | 0.2% |
| Isc | 14.18 A | 14.31 A | 0.9% |
| Impp | 13.48 A | 13.61 A | 1.0% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
445 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 39.9 V | 39.75 V | 0.4% |
| Vmpp | 33.02 V | 33.21 V | 0.6% |
| Isc | 14.18 A | 13.9 A | 2.0% |
| Impp | 13.48 A | 13.4 A | 0.6% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
445 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 39.9 V | 39.58 V | 0.8% |
| Vmpp | 33.02 V | 33.02 V | 0.0% |
| Isc | 14.18 A | 14.3 A | 0.8% |
| Impp | 13.48 A | 13.48 A | 0.0% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
455 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 39.9 V | 39.98 V | 0.2% |
| Vmpp | 33.02 V | 33.42 V | 1.2% |
| Isc | 14.18 A | 14.45 A | 1.9% |
| Impp | 13.48 A | 13.61 A | 1.0% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
445 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 39.9 V | 39.7 V | 0.5% |
| Vmpp | 33.02 V | 32.99 V | 0.1% |
| Isc | 14.18 A | 14.19 A | 0.1% |
| Impp | 13.48 A | 13.49 A | 0.1% |
| TcVoc | -0.25 %/°C | -0.24 %/°C | ±0.010 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
450 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 39.9 V | 39.98 V | 0.2% |
| Vmpp | 33.02 V | 33.23 V | 0.6% |
| Isc | 14.18 A | 14.25 A | 0.5% |
| Impp | 13.48 A | 13.54 A | 0.4% |
| TcVoc | -0.25 %/°C | -0.24 %/°C | ±0.010 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
450 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 39.9 V | 39.78 V | 0.3% |
| Vmpp | 33.02 V | 33.48 V | 1.4% |
| Isc | 14.18 A | 14.36 A | 1.3% |
| Impp | 13.48 A | 13.44 A | 0.3% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
450 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 39.9 V | 40 V | 0.3% |
| Vmpp | 33.02 V | 33.46 V | 1.3% |
| Isc | 14.18 A | 13.95 A | 1.6% |
| Impp | 13.48 A | 13.45 A | 0.2% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
455 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 39.9 V | 39.94 V | 0.1% |
| Vmpp | 33.02 V | 33.64 V | 1.9% |
| Isc | 14.18 A | 14.43 A | 1.8% |
| Impp | 13.48 A | 13.53 A | 0.4% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
460 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 39.9 V | 40.01 V | 0.3% |
| Vmpp | 33.02 V | 33.05 V | 0.1% |
| Isc | 14.18 A | 14.69 A | 3.6% |
| Impp | 13.48 A | 13.93 A | 3.3% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
440 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 39.9 V | 39.61 V | 0.7% |
| Vmpp | 33.02 V | 32.79 V | 0.7% |
| Isc | 14.18 A | 14.11 A | 0.5% |
| Impp | 13.48 A | 13.42 A | 0.4% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
String Compatibility Calculator
Verify the replacement panel works with your inverter
Panel Matcher
Find all compatible panels for a specific inverter
Already have panels?
Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.
How the Algorithm Works
Learn how panels are scored and matched
Voc
39.9 V
Vmpp
33.02 V
Isc
14.18 A
Impp
13.48 A
TcVoc
-0.25 %/°C
TcPmax
-0.29 %/°C
Pmax
445 W
Cells
108
Bifaciality
80%
Length
1724 mm
Width
1134 mm
Thickness
35 mm
Weight
24.7 kg
The Phono Solar PS445M8GF-18/VNH is a 445 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.
Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.
| Model | Power | Voc | Isc |
|---|---|---|---|
| PS420M8GF-18/VNH | 420 W | 38.44 V | 13.83 A |
| PS425M8GF-18/VNH | 425 W | 38.73 V | 13.89 A |
| PS430M8GF-18/VNH | 430 W | 39.03 V | 13.95 A |
| PS435M8GF-18/VNH | 435 W | 39.32 V | 14.04 A |
| PS440M8GF-18/VNH | 440 W | 39.61 V | 14.11 A |
The most critical specs to match are: cell count (must be exactly 108), Voc close to 39.9 V (within ±5%), and temperature coefficient TcVoc close to -0.25%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.
A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.
If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original Phono Solar PS445M8GF-18/VNH.