715 W HJT solar panel with 132 cells. Voc 50.11 V · Isc 18.06 A · TcVoc -0.22%/°C.
Select the panel you want to replace
159 panels found · 4180 panels excluded
715 W
HJT| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.11 V | 50.09 V | 0.0% |
| Vmpp | 42.06 V | 42 V | 0.1% |
| Isc | 18.06 A | 18.1 A | 0.2% |
| Impp | 17 A | 17.05 A | 0.3% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
710 W
HJT| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.11 V | 50.09 V | 0.0% |
| Vmpp | 42.06 V | 42.04 V | 0.0% |
| Isc | 18.06 A | 17.94 A | 0.7% |
| Impp | 17 A | 16.89 A | 0.6% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
720 W
HJT| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.11 V | 50.18 V | 0.1% |
| Vmpp | 42.06 V | 42.08 V | 0.0% |
| Isc | 18.06 A | 18.19 A | 0.7% |
| Impp | 17 A | 17.13 A | 0.8% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
705 W
HJT| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.11 V | 50.01 V | 0.2% |
| Vmpp | 42.06 V | 41.93 V | 0.3% |
| Isc | 18.06 A | 18 A | 0.3% |
| Impp | 17 A | 16.95 A | 0.3% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
710 W
HJT| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.11 V | 50.01 V | 0.2% |
| Vmpp | 42.06 V | 41.99 V | 0.2% |
| Isc | 18.06 A | 17.97 A | 0.5% |
| Impp | 17 A | 16.91 A | 0.5% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
720 W
HJT| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.11 V | 50.22 V | 0.2% |
| Vmpp | 42.06 V | 42.16 V | 0.2% |
| Isc | 18.06 A | 18.15 A | 0.5% |
| Impp | 17 A | 17.08 A | 0.5% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
715 W
HJT| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.11 V | 50.23 V | 0.2% |
| Vmpp | 42.06 V | 42.16 V | 0.2% |
| Isc | 18.06 A | 18.01 A | 0.3% |
| Impp | 17 A | 16.96 A | 0.2% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
725 W
HJT| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.11 V | 50.26 V | 0.3% |
| Vmpp | 42.06 V | 42.14 V | 0.2% |
| Isc | 18.06 A | 18.29 A | 1.3% |
| Impp | 17 A | 17.23 A | 1.4% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
705 W
HJT| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.11 V | 49.96 V | 0.3% |
| Vmpp | 42.06 V | 41.91 V | 0.4% |
| Isc | 18.06 A | 17.87 A | 1.1% |
| Impp | 17 A | 16.82 A | 1.1% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
710 W
HJT| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.11 V | 49.92 V | 0.4% |
| Vmpp | 42.06 V | 41.86 V | 0.5% |
| Isc | 18.06 A | 17.91 A | 0.8% |
| Impp | 17 A | 16.86 A | 0.8% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
720 W
HJT| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.11 V | 50.36 V | 0.5% |
| Vmpp | 42.06 V | 42.28 V | 0.5% |
| Isc | 18.06 A | 18.08 A | 0.1% |
| Impp | 17 A | 17.03 A | 0.2% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
725 W
HJT| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.11 V | 50.31 V | 0.4% |
| Vmpp | 42.06 V | 42.25 V | 0.5% |
| Isc | 18.06 A | 18.24 A | 1.0% |
| Impp | 17 A | 17.16 A | 0.9% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
String Compatibility Calculator
Verify the replacement panel works with your inverter
Panel Matcher
Find all compatible panels for a specific inverter
Already have panels?
Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.
How the Algorithm Works
Learn how panels are scored and matched
Voc
50.11 V
Vmpp
42.06 V
Isc
18.06 A
Impp
17 A
TcVoc
-0.22 %/°C
TcPmax
-0.24 %/°C
Pmax
715 W
Cells
132
Bifaciality
90%
Length
2384 mm
Width
1303 mm
Thickness
33 mm
Weight
37.9 kg
The Phono Solar PS715M13GFH-22/WSHW is a 715 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.
Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.
| Model | Power | Voc | Isc |
|---|---|---|---|
| PS710M13GFH-22/WSHW | 710 W | 50.01 V | 17.97 A |
| PS720M13GFH-22/WSHW | 720 W | 50.22 V | 18.15 A |
| PS725M13GFH-22/WSHW | 725 W | 50.31 V | 18.24 A |
| PS730M13GFH-22/WSHW | 730 W | 50.42 V | 18.33 A |
The most critical specs to match are: cell count (must be exactly 132), Voc close to 50.11 V (within ±5%), and temperature coefficient TcVoc close to -0.22%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.
A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.
If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original Phono Solar PS715M13GFH-22/WSHW.