405 W PERC solar panel with 132 cells. Voc 45.34 V · Isc 11.17 A · TcVoc -0.27%/°C.
Select the panel you want to replace
11 panels found · 4328 panels excluded
400 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 45.34 V | 45.3 V | 0.1% |
| Vmpp | 37.39 V | 37.13 V | 0.7% |
| Isc | 11.17 A | 11.14 A | 0.3% |
| Impp | 10.83 A | 10.77 A | 0.6% |
| TcVoc | -0.27 %/°C | -0.27 %/°C | ±0.000 %/°C |
| TcPmax | -0.34 %/°C | -0.34 %/°C | ±0.000 %/°C |
410 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 45.34 V | 45.37 V | 0.1% |
| Vmpp | 37.39 V | 37.64 V | 0.7% |
| Isc | 11.17 A | 11.2 A | 0.3% |
| Impp | 10.83 A | 10.89 A | 0.6% |
| TcVoc | -0.27 %/°C | -0.27 %/°C | ±0.000 %/°C |
| TcPmax | -0.34 %/°C | -0.34 %/°C | ±0.000 %/°C |
395 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 45.34 V | 45.27 V | 0.2% |
| Vmpp | 37.39 V | 36.88 V | 1.4% |
| Isc | 11.17 A | 11.1 A | 0.6% |
| Impp | 10.83 A | 10.71 A | 1.1% |
| TcVoc | -0.27 %/°C | -0.27 %/°C | ±0.000 %/°C |
| TcPmax | -0.34 %/°C | -0.34 %/°C | ±0.000 %/°C |
415 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 45.34 V | 45.41 V | 0.2% |
| Vmpp | 37.39 V | 37.89 V | 1.3% |
| Isc | 11.17 A | 11.23 A | 0.5% |
| Impp | 10.83 A | 10.95 A | 1.1% |
| TcVoc | -0.27 %/°C | -0.27 %/°C | ±0.000 %/°C |
| TcPmax | -0.34 %/°C | -0.34 %/°C | ±0.000 %/°C |
390 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 45.34 V | 45.23 V | 0.2% |
| Vmpp | 37.39 V | 36.62 V | 2.1% |
| Isc | 11.17 A | 11.07 A | 0.9% |
| Impp | 10.83 A | 10.65 A | 1.7% |
| TcVoc | -0.27 %/°C | -0.27 %/°C | ±0.000 %/°C |
| TcPmax | -0.34 %/°C | -0.34 %/°C | ±0.000 %/°C |
385 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 45.34 V | 45.19 V | 0.3% |
| Vmpp | 37.39 V | 36.36 V | 2.8% |
| Isc | 11.17 A | 11.04 A | 1.2% |
| Impp | 10.83 A | 10.59 A | 2.2% |
| TcVoc | -0.27 %/°C | -0.27 %/°C | ±0.000 %/°C |
| TcPmax | -0.34 %/°C | -0.34 %/°C | ±0.000 %/°C |
405 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 45.34 V | 45.1 V | 0.5% |
| Vmpp | 37.39 V | 37.3 V | 0.2% |
| Isc | 11.17 A | 11.35 A | 1.6% |
| Impp | 10.83 A | 10.86 A | 0.3% |
| TcVoc | -0.27 %/°C | -0.28 %/°C | ±0.010 %/°C |
| TcPmax | -0.34 %/°C | -0.36 %/°C | ±0.020 %/°C |
400 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 45.34 V | 44.9 V | 1.0% |
| Vmpp | 37.39 V | 37.1 V | 0.8% |
| Isc | 11.17 A | 11.28 A | 1.0% |
| Impp | 10.83 A | 10.79 A | 0.4% |
| TcVoc | -0.27 %/°C | -0.28 %/°C | ±0.010 %/°C |
| TcPmax | -0.34 %/°C | -0.36 %/°C | ±0.020 %/°C |
410 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 45.34 V | 45.8 V | 1.0% |
| Vmpp | 37.39 V | 37.6 V | 0.6% |
| Isc | 11.17 A | 11.41 A | 2.1% |
| Impp | 10.83 A | 10.9 A | 0.6% |
| TcVoc | -0.27 %/°C | -0.28 %/°C | ±0.010 %/°C |
| TcPmax | -0.34 %/°C | -0.36 %/°C | ±0.020 %/°C |
395 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 45.34 V | 44.7 V | 1.4% |
| Vmpp | 37.39 V | 36.9 V | 1.3% |
| Isc | 11.17 A | 11.21 A | 0.4% |
| Impp | 10.83 A | 10.73 A | 0.9% |
| TcVoc | -0.27 %/°C | -0.28 %/°C | ±0.010 %/°C |
| TcPmax | -0.34 %/°C | -0.36 %/°C | ±0.020 %/°C |
390 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 45.34 V | 44.5 V | 1.9% |
| Vmpp | 37.39 V | 36.7 V | 1.8% |
| Isc | 11.17 A | 11.14 A | 0.3% |
| Impp | 10.83 A | 10.63 A | 1.8% |
| TcVoc | -0.27 %/°C | -0.28 %/°C | ±0.010 %/°C |
| TcPmax | -0.34 %/°C | -0.36 %/°C | ±0.020 %/°C |
String Compatibility Calculator
Verify the replacement panel works with your inverter
Panel Matcher
Find all compatible panels for a specific inverter
Already have panels?
Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.
How the Algorithm Works
Learn how panels are scored and matched
Voc
45.34 V
Vmpp
37.39 V
Isc
11.17 A
Impp
10.83 A
TcVoc
-0.27 %/°C
TcPmax
-0.34 %/°C
Pmax
405 W
Cells
132
Length
1879 mm
Width
1045 mm
Thickness
32 mm
Weight
22 kg
The Qcells Q.PEAK DUO BLK ML-G10+ 405 is a 405 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.
Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.
| Model | Power | Voc | Isc |
|---|---|---|---|
| Q.PEAK DUO BLK ML-G10+ 385 | 385 W | 45.19 V | 11.04 A |
| Q.PEAK DUO BLK ML-G10+ 390 | 390 W | 45.23 V | 11.07 A |
| Q.PEAK DUO BLK ML-G10+ 395 | 395 W | 45.27 V | 11.1 A |
| Q.PEAK DUO BLK ML-G10+ 400 | 400 W | 45.3 V | 11.14 A |
| Q.PEAK DUO BLK ML-G10+ 410 | 410 W | 45.37 V | 11.2 A |
| Q.PEAK DUO BLK ML-G10+ 415 | 415 W | 45.41 V | 11.23 A |
The most critical specs to match are: cell count (must be exactly 132), Voc close to 45.34 V (within ±5%), and temperature coefficient TcVoc close to -0.27%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.
A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.
If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original Qcells Q.PEAK DUO BLK ML-G10+ 405.