Free solar panel & inverter compatibility checker. Verify your PV string configuration is safe before installation.

Tools

  • Calculator
  • Panel Matcher
  • Inverter Finder
  • Inverter Compare
  • Panel Replacement
  • Cable sizing

Resources

  • Guides
  • How it works
  • Standards & Compliance
  • Data API
  • Replacement methodology
  • Add Equipment
  • Feedback

Legal

  • About
  • Privacy Policy
  • Terms of Service
  • Cookie Policy

© 2026 Solar Stack

All replacements

Find replacement for Qcells Q.PEAK DUO-G6 340

340 W PERC solar panel with 120 cells. Voc 40.24 V · Isc 10.68 A · TcVoc -0.27%/°C.

Select the panel you want to replace

Show only panels with matching cell technology

Compatible Replacements

15 panels found · 4324 panels excluded

Qcells Q.PEAK DUO-G6 345

345 W

PERC
87Good match
ParameterOriginalReplacementDeviation
Voc40.24 V40.49 V0.6%
Vmpp33.45 V33.76 V0.9%
Isc10.68 A10.73 A0.5%
Impp10.16 A10.22 A0.6%
TcVoc-0.27 %/°C-0.27 %/°C±0.000 %/°C
TcPmax-0.36 %/°C-0.36 %/°C±0.000 %/°C
Qcells Q.PEAK DUO-G6 350

350 W

PERC
74Acceptable
ParameterOriginalReplacementDeviation
Voc40.24 V40.73 V1.2%
Vmpp33.45 V34.07 V1.9%
Isc10.68 A10.79 A1.0%
Impp10.16 A10.27 A1.1%
TcVoc-0.27 %/°C-0.27 %/°C±0.000 %/°C
TcPmax-0.36 %/°C-0.36 %/°C±0.000 %/°C
AXITEC AC-325MH/120V

325 W

PERC
67Acceptable
ParameterOriginalReplacementDeviation
Voc40.24 V40.37 V0.3%
Vmpp33.45 V33.45 V0.0%
Isc10.68 A10.18 A4.7%
Impp10.16 A9.73 A4.2%
TcVoc-0.27 %/°C-0.29 %/°C±0.020 %/°C
TcPmax-0.36 %/°C-0.39 %/°C±0.030 %/°C
Bauer Solar BS-325-6MHB5-EL

325 W

PERC
67Acceptable
ParameterOriginalReplacementDeviation
Voc40.24 V40.4 V0.4%
Vmpp33.45 V33.5 V0.1%
Isc10.68 A10.28 A3.7%
Impp10.16 A9.71 A4.4%
TcVoc-0.27 %/°C-0.29 %/°C±0.020 %/°C
TcPmax-0.36 %/°C-0.39 %/°C±0.030 %/°C
AXITEC AC-320MH/120V

320 W

PERC
66Acceptable
ParameterOriginalReplacementDeviation
Voc40.24 V40.25 V0.0%
Vmpp33.45 V33.21 V0.7%
Isc10.68 A10.11 A5.3%
Impp10.16 A9.64 A5.1%
TcVoc-0.27 %/°C-0.29 %/°C±0.020 %/°C
TcPmax-0.36 %/°C-0.39 %/°C±0.030 %/°C
S-Energy SL45-60MBI-360Z

360 W

PERC
61Acceptable
ParameterOriginalReplacementDeviation
Voc40.24 V40.6 V0.9%
Vmpp33.45 V33.8 V1.0%
Isc10.68 A11.24 A5.2%
Impp10.16 A10.66 A4.9%
TcVoc-0.27 %/°C-0.29 %/°C±0.020 %/°C
TcPmax-0.36 %/°C-0.36 %/°C±0.000 %/°C
AXITEC AC-330MH/120V

330 W

PERC
61Acceptable
ParameterOriginalReplacementDeviation
Voc40.24 V40.49 V0.6%
Vmpp33.45 V33.74 V0.9%
Isc10.68 A10.25 A4.0%
Impp10.16 A9.79 A3.6%
TcVoc-0.27 %/°C-0.29 %/°C±0.020 %/°C
TcPmax-0.36 %/°C-0.39 %/°C±0.030 %/°C
Qcells Q.PEAK DUO-G6 355

355 W

PERC
61Acceptable
ParameterOriginalReplacementDeviation
Voc40.24 V40.98 V1.8%
Vmpp33.45 V34.38 V2.8%
Isc10.68 A10.84 A1.5%
Impp10.16 A10.33 A1.7%
TcVoc-0.27 %/°C-0.27 %/°C±0.000 %/°C
TcPmax-0.36 %/°C-0.36 %/°C±0.000 %/°C
S-Energy SL45-60MAI-360Z

360 W

PERC
61Acceptable
ParameterOriginalReplacementDeviation
Voc40.24 V40.6 V0.9%
Vmpp33.45 V33.8 V1.0%
Isc10.68 A11.24 A5.2%
Impp10.16 A10.66 A4.9%
TcVoc-0.27 %/°C-0.29 %/°C±0.020 %/°C
TcPmax-0.36 %/°C-0.36 %/°C±0.000 %/°C
S-Energy SL45-60MCI-360Z

360 W

PERC
61Acceptable
ParameterOriginalReplacementDeviation
Voc40.24 V40.6 V0.9%
Vmpp33.45 V33.8 V1.0%
Isc10.68 A11.24 A5.2%
Impp10.16 A10.66 A4.9%
TcVoc-0.27 %/°C-0.29 %/°C±0.020 %/°C
TcPmax-0.36 %/°C-0.36 %/°C±0.000 %/°C
Bauer Solar BS-330-6MHB5-EL

330 W

PERC
60Acceptable
ParameterOriginalReplacementDeviation
Voc40.24 V40.6 V0.9%
Vmpp33.45 V33.7 V0.7%
Isc10.68 A10.35 A3.1%
Impp10.16 A9.8 A3.5%
TcVoc-0.27 %/°C-0.29 %/°C±0.020 %/°C
TcPmax-0.36 %/°C-0.39 %/°C±0.030 %/°C
AXITEC AC-335MH/120V

335 W

PERC
55Marginal
ParameterOriginalReplacementDeviation
Voc40.24 V40.65 V1.0%
Vmpp33.45 V33.98 V1.6%
Isc10.68 A10.31 A3.5%
Impp10.16 A9.87 A2.9%
TcVoc-0.27 %/°C-0.29 %/°C±0.020 %/°C
TcPmax-0.36 %/°C-0.39 %/°C±0.030 %/°C

String Compatibility Calculator

Verify the replacement panel works with your inverter

Panel Matcher

Find all compatible panels for a specific inverter

Already have panels?

Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.

How the Algorithm Works

Learn how panels are scored and matched

Original Panel Specs

Voc

40.24 V

Vmpp

33.45 V

Isc

10.68 A

Impp

10.16 A

TcVoc

-0.27 %/°C

TcPmax

-0.36 %/°C

Pmax

340 W

Cells

120

Length

1740 mm

Width

1030 mm

Thickness

32 mm

Weight

19.9 kg

The Qcells Q.PEAK DUO-G6 340 is a 340 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.

Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.

Other models in this series

ModelPowerVocIsc
Q.PEAK DUO-G6 345345 W40.49 V10.73 A
Q.PEAK DUO-G6 350350 W40.73 V10.79 A
Q.PEAK DUO-G6 355355 W40.98 V10.84 A

Frequently Asked Questions

What specs must match when replacing the Qcells Q.PEAK DUO-G6 340?

The most critical specs to match are: cell count (must be exactly 120), Voc close to 40.24 V (within ±5%), and temperature coefficient TcVoc close to -0.27%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.

Can I use a higher wattage replacement for the Qcells Q.PEAK DUO-G6 340?

A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.

What happens if the replacement panel has different voltage specs?

If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original Qcells Q.PEAK DUO-G6 340.