580 W PERC solar panel with 156 cells. Voc 53.43 V · Isc 13.81 A · TcVoc -0.26%/°C.
Select the panel you want to replace
20 panels found · 4319 panels excluded
580 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 53.43 V | 53.43 V | 0.0% |
| Vmpp | 44.81 V | 44.81 V | 0.0% |
| Isc | 13.81 A | 13.81 A | 0.0% |
| Impp | 12.95 A | 12.95 A | 0.0% |
| TcVoc | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
| TcPmax | -0.34 %/°C | -0.34 %/°C | ±0.000 %/°C |
585 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 53.43 V | 53.63 V | 0.4% |
| Vmpp | 44.81 V | 45.01 V | 0.4% |
| Isc | 13.81 A | 13.87 A | 0.4% |
| Impp | 12.95 A | 13.01 A | 0.5% |
| TcVoc | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
| TcPmax | -0.34 %/°C | -0.34 %/°C | ±0.000 %/°C |
585 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 53.43 V | 53.63 V | 0.4% |
| Vmpp | 44.81 V | 45.01 V | 0.4% |
| Isc | 13.81 A | 13.87 A | 0.4% |
| Impp | 12.95 A | 13.01 A | 0.5% |
| TcVoc | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
| TcPmax | -0.34 %/°C | -0.34 %/°C | ±0.000 %/°C |
575 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 53.43 V | 53.45 V | 0.0% |
| Vmpp | 44.81 V | 44.93 V | 0.3% |
| Isc | 13.81 A | 13.69 A | 0.9% |
| Impp | 12.95 A | 12.8 A | 1.2% |
| TcVoc | -0.26 %/°C | -0.25 %/°C | ±0.010 %/°C |
| TcPmax | -0.34 %/°C | -0.34 %/°C | ±0.000 %/°C |
570 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 53.43 V | 53.29 V | 0.3% |
| Vmpp | 44.81 V | 44.79 V | 0.0% |
| Isc | 13.81 A | 13.63 A | 1.3% |
| Impp | 12.95 A | 12.73 A | 1.7% |
| TcVoc | -0.26 %/°C | -0.25 %/°C | ±0.010 %/°C |
| TcPmax | -0.34 %/°C | -0.34 %/°C | ±0.000 %/°C |
580 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 53.43 V | 53.59 V | 0.3% |
| Vmpp | 44.81 V | 45.05 V | 0.5% |
| Isc | 13.81 A | 13.76 A | 0.4% |
| Impp | 12.95 A | 12.88 A | 0.5% |
| TcVoc | -0.26 %/°C | -0.25 %/°C | ±0.010 %/°C |
| TcPmax | -0.34 %/°C | -0.34 %/°C | ±0.000 %/°C |
585 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 53.43 V | 53.73 V | 0.6% |
| Vmpp | 44.81 V | 45.21 V | 0.9% |
| Isc | 13.81 A | 13.83 A | 0.1% |
| Impp | 12.95 A | 12.95 A | 0.0% |
| TcVoc | -0.26 %/°C | -0.25 %/°C | ±0.010 %/°C |
| TcPmax | -0.34 %/°C | -0.34 %/°C | ±0.000 %/°C |
590 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 53.43 V | 53.83 V | 0.7% |
| Vmpp | 44.81 V | 45.21 V | 0.9% |
| Isc | 13.81 A | 13.93 A | 0.9% |
| Impp | 12.95 A | 13.06 A | 0.8% |
| TcVoc | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
| TcPmax | -0.34 %/°C | -0.34 %/°C | ±0.000 %/°C |
590 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 53.43 V | 53.83 V | 0.7% |
| Vmpp | 44.81 V | 45.21 V | 0.9% |
| Isc | 13.81 A | 13.93 A | 0.9% |
| Impp | 12.95 A | 13.06 A | 0.8% |
| TcVoc | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
| TcPmax | -0.34 %/°C | -0.34 %/°C | ±0.000 %/°C |
565 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 53.43 V | 53.18 V | 0.5% |
| Vmpp | 44.81 V | 44.67 V | 0.3% |
| Isc | 13.81 A | 13.55 A | 1.9% |
| Impp | 12.95 A | 12.65 A | 2.3% |
| TcVoc | -0.26 %/°C | -0.25 %/°C | ±0.010 %/°C |
| TcPmax | -0.34 %/°C | -0.34 %/°C | ±0.000 %/°C |
590 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 53.43 V | 53.85 V | 0.8% |
| Vmpp | 44.81 V | 44.73 V | 0.2% |
| Isc | 13.81 A | 14.05 A | 1.7% |
| Impp | 12.95 A | 13.2 A | 1.9% |
| TcVoc | -0.26 %/°C | -0.269 %/°C | ±0.009 %/°C |
| TcPmax | -0.34 %/°C | -0.335 %/°C | ±0.005 %/°C |
560 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 53.43 V | 53.07 V | 0.7% |
| Vmpp | 44.81 V | 44.56 V | 0.6% |
| Isc | 13.81 A | 13.49 A | 2.3% |
| Impp | 12.95 A | 12.57 A | 2.9% |
| TcVoc | -0.26 %/°C | -0.25 %/°C | ±0.010 %/°C |
| TcPmax | -0.34 %/°C | -0.34 %/°C | ±0.000 %/°C |
String Compatibility Calculator
Verify the replacement panel works with your inverter
Panel Matcher
Find all compatible panels for a specific inverter
Already have panels?
Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.
How the Algorithm Works
Learn how panels are scored and matched
Voc
53.43 V
Vmpp
44.81 V
Isc
13.81 A
Impp
12.95 A
TcVoc
-0.26 %/°C
TcPmax
-0.34 %/°C
Pmax
580 W
Cells
156
Bifaciality
70%
Length
2465 mm
Width
1134 mm
Thickness
35 mm
Weight
29.5 kg
The Seraphim SRP-580-BMZ-HV is a 580 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.
Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.
| Model | Power | Voc | Isc |
|---|---|---|---|
| SRP-585-BMZ-HV | 585 W | 53.63 V | 13.87 A |
| SRP-590-BMZ-HV | 590 W | 53.83 V | 13.93 A |
| SRP-595-BMZ-HV | 595 W | 54.03 V | 13.99 A |
| SRP-600-BMZ-HV | 600 W | 54.23 V | 14.05 A |
| SRP-605-BMZ-HV | 605 W | 54.43 V | 14.11 A |
The most critical specs to match are: cell count (must be exactly 156), Voc close to 53.43 V (within ±5%), and temperature coefficient TcVoc close to -0.26%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.
A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.
If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original Seraphim SRP-580-BMZ-HV.