325 W PERC solar panel with 60 cells. Voc 40.41 V · Isc 10.31 A · TcVoc -0.28%/°C.
Select the panel you want to replace
5 panels found · 4334 panels excluded
320 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 40.41 V | 40.22 V | 0.5% |
| Vmpp | 33.85 V | 33.61 V | 0.7% |
| Isc | 10.31 A | 10.2 A | 1.1% |
| Impp | 9.6 A | 9.52 A | 0.8% |
| TcVoc | -0.28 %/°C | -0.28 %/°C | ±0.000 %/°C |
| TcPmax | -0.39 %/°C | -0.39 %/°C | ±0.000 %/°C |
330 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 40.41 V | 40.6 V | 0.5% |
| Vmpp | 33.85 V | 34.09 V | 0.7% |
| Isc | 10.31 A | 10.42 A | 1.1% |
| Impp | 9.6 A | 9.68 A | 0.8% |
| TcVoc | -0.28 %/°C | -0.28 %/°C | ±0.000 %/°C |
| TcPmax | -0.39 %/°C | -0.39 %/°C | ±0.000 %/°C |
305 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 40.41 V | 39.9 V | 1.3% |
| Vmpp | 33.85 V | 33.2 V | 1.9% |
| Isc | 10.31 A | 9.64 A | 6.5% |
| Impp | 9.6 A | 9.2 A | 4.2% |
| TcVoc | -0.28 %/°C | -0.273 %/°C | ±0.007 %/°C |
| TcPmax | -0.39 %/°C | -0.389 %/°C | ±0.001 %/°C |
310 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 40.41 V | 39.36 V | 2.6% |
| Vmpp | 33.85 V | 31.83 V | 6.0% |
| Isc | 10.31 A | 10.29 A | 0.2% |
| Impp | 9.6 A | 9.74 A | 1.5% |
| TcVoc | -0.28 %/°C | -0.273 %/°C | ±0.007 %/°C |
| TcPmax | -0.39 %/°C | -0.389 %/°C | ±0.001 %/°C |
305 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 40.41 V | 39.49 V | 2.3% |
| Vmpp | 33.85 V | 32.35 V | 4.4% |
| Isc | 10.31 A | 9.86 A | 4.4% |
| Impp | 9.6 A | 9.43 A | 1.8% |
| TcVoc | -0.28 %/°C | -0.318 %/°C | ±0.038 %/°C |
| TcPmax | -0.39 %/°C | -0.427 %/°C | ±0.037 %/°C |
String Compatibility Calculator
Verify the replacement panel works with your inverter
Panel Matcher
Find all compatible panels for a specific inverter
Already have panels?
Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.
How the Algorithm Works
Learn how panels are scored and matched
Voc
40.41 V
Vmpp
33.85 V
Isc
10.31 A
Impp
9.6 A
TcVoc
-0.28 %/°C
TcPmax
-0.39 %/°C
Pmax
325 W
Cells
60
Length
1700 mm
Width
1000 mm
Thickness
35 mm
Weight
19 kg
The Sonnenstromfabrik EXCELLENT 325 M60 is a 325 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.
Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.
| Model | Power | Voc | Isc |
|---|---|---|---|
| EXCELLENT 320 M60 | 320 W | 40.22 V | 10.2 A |
| EXCELLENT 330 M60 | 330 W | 40.6 V | 10.42 A |
The most critical specs to match are: cell count (must be exactly 60), Voc close to 40.41 V (within ±5%), and temperature coefficient TcVoc close to -0.28%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.
A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.
If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original Sonnenstromfabrik EXCELLENT 325 M60.