620 W TOPCon solar panel with 132 cells. Voc 49.3 V · Isc 15.76 A · TcVoc -0.23%/°C.
Select the panel you want to replace
50 panels found · 4289 panels excluded
630 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.3 V | 49.7 V | 0.8% |
| Vmpp | 41.9 V | 42.3 V | 1.0% |
| Isc | 15.76 A | 15.81 A | 0.3% |
| Impp | 14.8 A | 14.9 A | 0.7% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
615 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.3 V | 49.3 V | 0.0% |
| Vmpp | 41.9 V | 41.1 V | 1.9% |
| Isc | 15.76 A | 15.89 A | 0.8% |
| Impp | 14.8 A | 14.98 A | 1.2% |
| TcVoc | -0.23 %/°C | -0.24 %/°C | ±0.010 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
610 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.3 V | 48.9 V | 0.8% |
| Vmpp | 41.9 V | 41.5 V | 1.0% |
| Isc | 15.76 A | 15.7 A | 0.4% |
| Impp | 14.8 A | 14.7 A | 0.7% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
615 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.3 V | 49.3 V | 0.0% |
| Vmpp | 41.9 V | 41.1 V | 1.9% |
| Isc | 15.76 A | 15.89 A | 0.8% |
| Impp | 14.8 A | 14.98 A | 1.2% |
| TcVoc | -0.23 %/°C | -0.24 %/°C | ±0.010 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
615 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.3 V | 49.3 V | 0.0% |
| Vmpp | 41.9 V | 41.1 V | 1.9% |
| Isc | 15.76 A | 15.89 A | 0.8% |
| Impp | 14.8 A | 14.98 A | 1.2% |
| TcVoc | -0.23 %/°C | -0.24 %/°C | ±0.010 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
620 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.3 V | 49.6 V | 0.6% |
| Vmpp | 41.9 V | 41.4 V | 1.2% |
| Isc | 15.76 A | 15.91 A | 1.0% |
| Impp | 14.8 A | 14.99 A | 1.3% |
| TcVoc | -0.23 %/°C | -0.24 %/°C | ±0.010 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
620 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.3 V | 49.6 V | 0.6% |
| Vmpp | 41.9 V | 41.4 V | 1.2% |
| Isc | 15.76 A | 15.91 A | 1.0% |
| Impp | 14.8 A | 14.99 A | 1.3% |
| TcVoc | -0.23 %/°C | -0.24 %/°C | ±0.010 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
620 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.3 V | 49.6 V | 0.6% |
| Vmpp | 41.9 V | 41.4 V | 1.2% |
| Isc | 15.76 A | 15.91 A | 1.0% |
| Impp | 14.8 A | 14.99 A | 1.3% |
| TcVoc | -0.23 %/°C | -0.24 %/°C | ±0.010 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
625 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.3 V | 49.8 V | 1.0% |
| Vmpp | 41.9 V | 41.6 V | 0.7% |
| Isc | 15.76 A | 15.93 A | 1.1% |
| Impp | 14.8 A | 15 A | 1.4% |
| TcVoc | -0.23 %/°C | -0.24 %/°C | ±0.010 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
625 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.3 V | 49.8 V | 1.0% |
| Vmpp | 41.9 V | 41.6 V | 0.7% |
| Isc | 15.76 A | 15.93 A | 1.1% |
| Impp | 14.8 A | 15 A | 1.4% |
| TcVoc | -0.23 %/°C | -0.24 %/°C | ±0.010 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
625 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.3 V | 49.9 V | 1.2% |
| Vmpp | 41.9 V | 41.7 V | 0.5% |
| Isc | 15.76 A | 15.92 A | 1.0% |
| Impp | 14.8 A | 15 A | 1.4% |
| TcVoc | -0.23 %/°C | -0.24 %/°C | ±0.010 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
610 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.3 V | 49 V | 0.6% |
| Vmpp | 41.9 V | 40.8 V | 2.6% |
| Isc | 15.76 A | 15.86 A | 0.6% |
| Impp | 14.8 A | 14.96 A | 1.1% |
| TcVoc | -0.23 %/°C | -0.24 %/°C | ±0.010 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
String Compatibility Calculator
Verify the replacement panel works with your inverter
Panel Matcher
Find all compatible panels for a specific inverter
Already have panels?
Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.
How the Algorithm Works
Learn how panels are scored and matched
Voc
49.3 V
Vmpp
41.9 V
Isc
15.76 A
Impp
14.8 A
TcVoc
-0.23 %/°C
TcPmax
-0.29 %/°C
Pmax
620 W
Cells
132
Length
2382 mm
Width
1134 mm
Thickness
30 mm
Weight
28 kg
The Sun Earth DXM10-66H 620W is a 620 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.
Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.
| Model | Power | Voc | Isc |
|---|---|---|---|
| DXM10-66H 600W | 600 W | 48.5 V | 15.64 A |
| DXM10-66H 610W | 610 W | 48.9 V | 15.7 A |
| DXM10-66H 630W | 630 W | 49.7 V | 15.81 A |
| DXM10-66H 640W | 640 W | 50.1 V | 15.87 A |
| DXM10-66H 650W | 650 W | 50.5 V | 15.93 A |
The most critical specs to match are: cell count (must be exactly 132), Voc close to 49.3 V (within ±5%), and temperature coefficient TcVoc close to -0.23%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.
A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.
If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original Sun Earth DXM10-66H 620W.